OSPREY

OSPREY is a 2002 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in May 2026, along with 11 deficiencies and 1 casualty investigation in 2010.

Records from 2010 to 2026. Most recent: inspection, 26 May 2026.

Built
2002
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCT8456
574424
Flag
UNITED STATES
Maury page id
psix-574424

Documentation record

Registered dimensions (L × B × D)64.7 ft × 23.0 ft × 3.5 ft
Registered tonnagegross 43 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFINNEY BOAT WORKS · POST FALLS, ID, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeBox
Hull configurationMonohull
Hailing portCOEUR D'ALENE, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

26 May 2026 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8373120
19 June 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8153774
6 June 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7929794
17 May 2023 Annual Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7715035
28 April 2022 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7440130
4 May 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189472
29 January 2021 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7215620
13 July 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7005573
20 May 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698690
3 May 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405257
17 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6143388
27 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6136233
3 May 2016 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5868556

Deficiency record · 11

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. When testing pre-engineered system, the generator installed in the same space failed to shut-down.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 3 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Flexible hose had failed on main eng, leaking diesel into space.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 June 2024
Resolved 7 June 2024
Resolution: identified and repaired the hose
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2023 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. (Annually)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 17 May 2023
Resolution: Corrected on day of inspection. Extinguishers serviced by fire servicing facility.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 April 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Wiring from penetrations need to be made watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2022
Resolution: Received photographic evidence.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 May 2021 Resolved
Make bulkheads watertight where shore tie cabling penetrates bulkheads.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 1 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2021 Resolved
ossible inadequate fire main pressure, provide gauge for fire pump discharge and indicate pressure achieved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 1 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2018 Resolved
Provide 01 additional child size life jacket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 8 May 2018
Resolution: Provided additional child size life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2018 Resolved
Properly label life jacket stowage on upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 8 May 2018
Resolution: Properly labeled stowage container
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2017 Resolved
Prove automatic shutdown of port main engine with pre-engineered fire extinguishing system actuation IAW 46CFR184.710.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Technician effectively repaired system, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2017 Resolved
Replece expired contents of first aid kit IAW 46CFR184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 24 May 2017
Resolution: Received notification from vessel Rep [name withheld] that a new CG approved first aid kit was purchased and placed into service on the vessel.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 May 2017 Resolved
03 life jackets were found to be unservicable IAW 46CFR176.808(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Life jackets were replaced with servicable life jackets.

Casualty record · 1

16 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3800708
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.