OSPREY is a 2002 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2002, most recently in May 2026, along with 23 deficiencies and 1 casualty investigation in 2010.

Records from 2002 to 2026. Most recent: inspection, 26 May 2026.

Built
2002
Last inspected
26 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCT8456
574424
Flag
UNITED STATES
—
Maury page id
psix-574424

Inspections, by type

Years with a record 19 calendar years (2002–2026)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.7 ft × 23.0 ft × 3.5 ft
Registered tonnagegross 43 / net 35
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFINNEY BOAT WORKS · POST FALLS, ID, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeBox
Hull configurationMonohull
Hailing portCOEUR D'ALENE, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Gross Ton
35 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

26 May 2026 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8373120
19 June 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8153774
6 June 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7929794
17 May 2023 Annual Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7715035
28 April 2022 Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7440130
4 May 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189472
29 January 2021 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7215620
13 July 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7005573
20 May 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698690
3 May 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405257
17 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6143388
27 April 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6136233
3 May 2016 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5868556
2 May 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4858851
5 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4202235
10 December 2008 DAPI Audit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3399130
25 June 2008 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3252917
23 May 2007 Hull Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2928050
19 July 2006 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2718609
25 August 2005 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2474653
1 June 2004 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2085162
24 June 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1693512

Deficiency record · 23

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 June 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. When testing pre-engineered system, the generator installed in the same space failed to shut-down.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 3 July 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Flexible hose had failed on main eng, leaking diesel into space.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 June 2024
Resolved 7 June 2024
Resolution: identified and repaired the hose
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2023 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. (Annually)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 17 May 2023
Resolution: Corrected on day of inspection. Extinguishers serviced by fire servicing facility.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 April 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Wiring from penetrations need to be made watertight.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 June 2022
Resolution: Received photographic evidence.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 May 2021 Resolved
Make bulkheads watertight where shore tie cabling penetrates bulkheads.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 1 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2021 Resolved
ossible inadequate fire main pressure, provide gauge for fire pump discharge and indicate pressure achieved.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 1 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2018 Resolved
Provide 01 additional child size life jacket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 8 May 2018
Resolution: Provided additional child size life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 May 2018 Resolved
Properly label life jacket stowage on upper deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2018
Resolved 8 May 2018
Resolution: Properly labeled stowage container
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2017 Resolved
Prove automatic shutdown of port main engine with pre-engineered fire extinguishing system actuation IAW 46CFR184.710.
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Technician effectively repaired system, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2017 Resolved
Replece expired contents of first aid kit IAW 46CFR184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 24 May 2017
Resolution: Received notification from vessel Rep [name withheld] that a new CG approved first aid kit was purchased and placed into service on the vessel.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 May 2017 Resolved
03 life jackets were found to be unservicable IAW 46CFR176.808(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Life jackets were replaced with servicable life jackets.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 2 May 2014 Resolved
Prove fire extinguishing system is capable of manual activation from outside the space IAW 46 CFR 181.420 (a) (2).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2014
Resolved 12 June 2016
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 10 December 2008 Resolved
Lake Couer d' Alene Cruise Line did not perform DOT Background checks of new employees IAW 49 CFR 40.25
Due 12 January 2009
Resolved 12 January 2009
Resolution: Lake Couer d'''' Alene Cruise Line Management Team will perfom background checks of all new employees who have worked for a DOT regulated employer in the previous two years.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 10 December 2008 Resolved
Lake Coeur d' Alene Cruise Line management did not submit a MIS report to CGHQ for 2006 & 2007 as required by 46 CFR 16.500.
Due 15 March 2009
Resolved 3 November 2009
Resolution: Satisfactory proof of submission provided to USCG
Electrical › Lighting (service) › Lighting Fixture
Issued 25 June 2008 Resolved
Provide light and explosion cover in space #4 from the bow.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 24 July 2008
Resolution: Cover installed
Lifesaving › Hand Flares › Expired
Issued 25 June 2008 Resolved
Provide 3 orange distress flares IAW 46 CFR 180.68 (b)(2). Flares expire at the end of the month in which the inspection was conducted.
Action required: 705 - Other - as specified
Due 25 July 2008
Resolved 24 July 2008
Resolution: New Flairs on Board
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 May 2007 Resolved
Inside the Accomodation spaces underneath the deck, there is wiring that feeds into an heating system, needs to be properly sealed
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 27 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 19 July 2006 Resolved
Auto shut down and over ride failed to work on port engine
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2006
Resolved 19 July 2006
Resolution: Repaired wiring to engine
Engineering › Bilge Water Management System
Issued 11 July 2002 Resolved
install bilge alarm in all spaces w/o water tight hatches. LEGACY COMPONENT DESC: Interface Detector
Condition: Unknown
Due 11 August 2002
Resolved 1 August 2002
Engineering › Generator (propulsion/auxiliary-electric)
Issued 11 July 2002 Resolved
install generator gauge set. LEGACY COMPONENT DESC: Indicator Circuitry
Condition: Design Flaw
Due 11 August 2002
Resolved 1 August 2002
Lifesaving › Hand Flares › Storage
Issued 11 July 2002 Resolved
provide orange container
Condition: Improper Installation
Due 11 August 2002
Resolved 1 August 2002
Navigation › Collision/Grounding Avoidance
Issued 11 July 2002 Resolved
provide bell LEGACY COMPONENT DESC: bell
Condition: Unknown
Due 11 August 2002
Resolved 1 August 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2002 Resolved
restock first aid kit
Condition: Improper/Lack of Maintenance
Due 11 August 2002
Resolved 1 August 2002

Casualty record · 1

16 July 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3800708
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.