MAURY USCG vessel records Sign in
← All vessels

VICTORY

VICTORY is a 2002 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2002, most recently in September 2015, along with 40 deficiencies — 28 with no resolution recorded — and 1 casualty investigation in 2013.

Records from 2002 to 2015. Most recent: inspection, 30 September 2015.

Built
2002
Last inspected
30 September 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8975811 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA9647
574433
Flag
UNITED STATES
366867460 (licence lapsed)
Maury page id
psix-574433

Inspections, by type

…with no type recorded3
…past their stated due date28
Years with a record 12 calendar years (2002–2015)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it325 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
97 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDA9647MMSI 366867460 · expired · compulsorily equipped · granted 25 July 2012, cancelled 5 November 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 19

30 September 2015 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5726123
11 August 2014 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4974123
25 July 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4390025
13 July 2012 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4376816
11 August 2011 Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 4123334
13 April 2009 Examination of Repairs · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3453344
14 July 2008 Internal Structural Exam · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3268784
1 November 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3092027
10 July 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2990353
17 May 2007 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2932375
16 August 2006 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2766047
14 September 2005 MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2556409
25 August 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2488185
18 August 2004 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2167685
16 September 2003 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1952002
6 August 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1868240
28 October 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1697120
6 September 2002 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1681237
30 August 2002 Initial Certification · Hull Examination · Construction Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1664243

Deficiency record · 40

Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 2 October 2015 No resolution recorded
The crew was not able to identify which watertight door was opened based on the way the panel was labeled on the operating station. Properly label the watertight door panel on the bridge IAW 179.330
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 2 October 2015 No resolution recorded
The sensor switch on the watertight door on frame 12 was found intentionally disabled to indicate the door was closed. Repair the sensor/ wire to truly indicate if the door is opened or closed IAW 46 CFR 179.330
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 2 October 2015 No resolution recorded
The watertight door on frame 12 was tied with a rag so that the dogs were inoperable. Remove rag and adjust dogs to ensure that door is operable from both sides IAW 46 CFR 179.330
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Navigation Safety › Doors Closed at Sea
Issued 2 October 2015 No resolution recorded
Watertight door at frame 12 was incapable of being closed as the dogs were misaligned. 46 CFR 179.330.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 2 October 2015 No resolution recorded
Watertight doors appeared to not be properly sealing, chalk test all watertight doors prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-electric) › Seal
Issued 2 October 2015 No resolution recorded
The number 3 main diesel engine was out of commission. Repair the main diesel engine to operable status 46 CFR 176.804. Contact USCG Sector Mobile Investigations to inform them of the loss of propulsion at [email withheld], Voice [phone withheld], or Fax [phone withheld].
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 2 October 2015 No resolution recorded
Both generators were leaking oil from rear seal. Clean generators and have ready for inspection to be able to further evaluate the leaks IAW 46 CFR 176.804.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 2 October 2015 No resolution recorded
The number 2 generator exhaust pipe showed evidence of leakage and was found apart and currently being worked on. Have generator ready for inspection IAW 46 CFR 176.804.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Pump
Issued 2 October 2015 No resolution recorded
Number 2 bilge pump was not operable. Repair bilge pump to be able to operate to its intended use IAW 46 CFR 182.520
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 October 2015 No resolution recorded
There was a substantial amount of oily water on engine room and aft steering bilges. Remove all oily water from bilges IAW 46 CFR 176.800.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 2 October 2015 No resolution recorded
Dirty oil tanks were full. Empty dirty oil tanks before getting underway IAW 46 CFR 176.800.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 October 2015 No resolution recorded
Unable to conduct underway drills due to the vessel’s inability to get underway for safety reasons (as mentioned above). Conduct drills before completing annual inspection IAW 46 CFR 185.520.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 October 2015 No resolution recorded
COI not posted anywhere on the vessel. Post COI under glass in accordance with (IAW) 46 CFR 176.302.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Stability Letter
Issued 2 October 2015 No resolution recorded
Stability Letter not posted anywhere on the vessel. Post stability letter under glass IAW 46 CFR 176.306.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 2 October 2015 No resolution recorded
There was no proof that any of the masters or crewmembers were enrolled in a random drug testing program. Enroll all employees in a random drug testing program and provide proof of the same IAW 46 CFR 16.230.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 October 2015 No resolution recorded
There were dead ended wires under the operating station console. Properly remove or cap wires to prevent electrical hazard IAW 46 CFR 183.340.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 2 October 2015 No resolution recorded
Alcohol test strips were expired. Replace all alcohol test strips with new ones IAW 46 CFR 16.240.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Lifesaving › Lifebuoys › Stowage
Issued 2 October 2015 No resolution recorded
Ring buoy on the port side of the bridge did not have a corrosion resistant clip. Install a corrosion resistant clip IAW 180.70.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Piping
Issued 2 October 2015 No resolution recorded
A section of the bilge piping leading to aft steering had a piece of rubber with a clamp covering a damaged section. Repair bilge piping IAW 46 CFR 182.510.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 2 October 2015 No resolution recorded
The EPIRB maintenance log showed evidence that there had been numerous months were no maintenance was performed. Perform maintenance on the EPIRB IAW 46 CFR 185.728.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 2 October 2015 No resolution recorded
All anchor shackles were not properly moused. Properly mouse all shackle to anchor IAW 46 CFR 184.300.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 2 October 2015 No resolution recorded
There was missing lagging on the #2 main diesel engine’s exhaust pipe. Properly install lagging on the #2 main diesel engine’s exhaust pipe IAW 46 CFR 182.425.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Electrical › Electric Generation Source (service) › Panelboard
Issued 2 October 2015 No resolution recorded
Distribution panel label “oil vent p-2) in aft engine room had loose handles and missing plastic plug missing of the face plate. Tighten loose handles and properly cover all open spaces on distribution panel IAW 46 CFR 183.330.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Fire Fighting › Fire Pumps › Arrangement
Issued 2 October 2015 No resolution recorded
The fire pump fixed piping system had a rubber hose in a section in place or hard piping. Replace the rubber hose with hard piping IAW 182.710
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 October 2015 No resolution recorded
Steering lines for steering pumps 1 and 2 were found bulging at both fittings. Replace both lines IAW 46 CFR 182.610.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 2 October 2015 No resolution recorded
There was a tool box in the engine room for properly secured for sea. Install a mounting bracket for the tool box IAW 46 CFR 182.100.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Tank
Issued 2 October 2015 No resolution recorded
A fuel tank on the starboard side did not have a sight glass to indicate fuel level. Install a means of determining the levels in the fuel tank IAW 46 CFR 182.445.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 2 October 2015 No resolution recorded
Loose gear was stowed on wire/cable runs throughout the engine room. Remove items from cable/wire runs IAW 46 CFRR 183.220.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 October 2015 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 July 2007 Resolved
Address all exhaust cracks/leaks on MDEs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 July 2007 Resolved
Repair water leaks on wet exhaust check valve box gaskets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2007
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 10 July 2007 Resolved
Replace all missing secondary closure devices on oil discharge lines and spigots in e/r.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 July 2007 Resolved
Repair leaking engine swing hatch cover on deck over stbd outboard MDE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 July 2007 Resolved
Replace two missing junction/electrical box covers in e/r.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 July 2007 Resolved
Properly mark and retro tape all lifebuoy rings onboard.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Electrical › Electric Generation Source (service) › Generator
Issued 10 July 2007 Resolved
Prove proper operation of each service generator and overspeed trip.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 6 August 2003 Resolved
PROVIDE AND POST INSTRUCTIONS FOR CO2 SYSTEM IN ALL AREAS. LEGACY COMPONENT DESC: INSTRUCTIONS
Action required: 705 - Other - as specified
Due 6 September 2003
Resolved 6 August 2003
Resolution: PROVIDED AND POSTED CO2 INSTRUCTIONS IN ALL AREAS.
Engineering › Steering Gear System
Issued 6 August 2003 Resolved
PROVIDE RUDDER LIMIT SWITCHES FOR STEERING SYSTEM. LEGACY COMPONENT DESC: RUDER LIMIT SWITCHES
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 16 September 2003
Resolution: PROVIDED RUDDER LIMIT SWITCHES.
Deck/Cargo › Vapor Control Systems
Issued 6 August 2003 Resolved
PROVIDE FLAME SCREEN FOR LUBE OIL TANK IN ENGINE ROOM. LEGACY COMPONENT DESC: Flame Screens
Action required: 705 - Other - as specified
Due 6 September 2003
Resolved 6 August 2003
Resolution: PROVIDED FLAME SCREENS FOR LUBE OIL TANK IN ENGINE ROOM.
Documentation › Certificates/Documents
Issued 6 August 2003 Resolved
PROVIDE BRIDGE TO BRIDGE RADIO CERTIFICATE. LEGACY COMPONENT DESC: BRIDGE TO BRIDGE RADIO CERTIFICATE.
Action required: 705 - Other - as specified
Due 6 September 2003
Resolved 6 August 2003
Resolution: PROVIDED BRIDGE TO BRIDGE RADIO CERTIFICATE.
Fire Fighting › Fixed Fire Detection System
Issued 30 August 2002 Resolved
Provide final approval certification for fire detection system. Reference Marine Safety Center letter 15 Mar 02, Serial number E2-020091. LEGACY COMPONENT DESC: Heat Detectors
Due 28 March 2003
Resolved 28 October 2002
Resolution: Recieved approval letter from the Marine Safety Center Serial number E2-0203519 Granting approval of the fire detection system.

Casualty record · 1

7 June 2013Routine · role: Involved in a Marine Casualty · activity 4625807
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GULF VICTORY (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record