DEWITT CLINTON

DEWITT CLINTON is a 1926 industrial vessel. The Coast Guard has recorded 5 inspections since 2017, most recently in September 2023, along with 14 deficiencies and 3 casualty investigations between 2011 and 2019.

Records from 2011 to 2023. Most recent: inspection, 5 September 2023.

Built
1926
Last inspected
5 September 2023
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 September 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-57497

Documentation record

Registered dimensions (L × B × D)42.3 ft × 14.0 ft × 6.6 ft
Registered tonnagegross 30 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEAST BOOTHBAY, ME, UNITED STATES · built 1926
Hull materialSteel
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portALBANY, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 August 2025 · expires 30 September 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Regulatory (Subpart C or D), Gross Ton
11 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

5 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; 3 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

5 September 2023 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7785198
3 October 2019 Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6828952
3 October 2019 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6830525
20 March 2019 Administrative Inspection · Damage Survey · Initial Certification · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6597241
6 September 2017 Industry Initiated Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6275123

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 October 2019 Resolved
Structural standards for an existing vessel must be such that the vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the [name withheld] to a recent marine casualty, the vessel's structure has come into question due to further wastage found throughout the hull. Vessel owner/operator has shown historical record that vessel's original hull thickness was at .25". Standards and good marine practice find that a vessels scantlings become unsatisfactory/deficient at or above 25% wastage. Wastage was found well beyond 25% throughout the hull by the owner/operator after most recent casualty. Vessel owner operator must address all deficient (<25% wastage) hull material and use good marine practice/techniques to resolve wasted sections.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 September 2023
Resolution: Vsl inactive
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 26 June 2019 Resolved
Safety orientations and other crew training must be documented in the TVR or official logbook. The entry must include:(1) The date of the safety orientation or training;(2) A general description of the safety orientation or training topics;(3) The name(s) and signature(s) of individual(s) providing the orientation or training; and(4) The name(s) of the individual(s) receiving the safety orientation or training. Crew training records not on board. Provide appropriate crew training records.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 23 October 2019
Resolution: Logbook provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2019 Resolved
All marine employers must submit drug testing program data required by 49 CFR 40.26vand appendix H to 49 CFR part 40. Vessel's O/O unaware of ManagementvInformation System (MIS) requirements. Ensure reporting procedures followed as per regulation
Action required: 10 - Deficiency Rectified
Due 26 June 2019
Resolved 26 June 2019
Resolution: Training conducted on marine employer responsibility.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 June 2019 Resolved
Towing vessels 26 ft or over in length, while underway on the Navigable Waters of the United States, must have two radiotelephones on board capable of operation from its navigational bridge, and capable of transmitting and receiving on the frequency or frequencies within the 156-162 MHz band for the exchange of navigational information. The radiotelephones must be capable of transmitting and receiving on VHF FM channel 13 (156.65 MHz) while also maintaining a continuous listening watch on the International Distress and Calling Channel, VHF FM Channel 16 (156.800). Vessel does not have 2 FCC station licensed radios on board. Provide applicable and satisfactory radios with corresponding station licenses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 5 September 2023
Resolution: Vsl inactive
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 26 June 2019 Resolved
All towing vessels must have an operational Health and Safety Plan in place no later than July 22, 2019. Vessel does not possess the required Health and Safety Plan. Have an operational safety and health plan in effect prior to 22 July 2019.
Action required: 705 - Other - as specified
Due 22 July 2019
Resolved 5 September 2023
Resolution: Vsl inactive
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 26 June 2019 Resolved
Each towing vessel must be equipped with an echo depthsounding device readable from the vessel's main steering station. No echo depth sounding device is on board. Prior to 2020 operating season vessel must be in compliance with this regulation.
Action required: 705 - Other - as specified
Resolved 5 September 2023
Resolution: Vsl inactive
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 26 June 2019 Resolved
Vessel must possess an illuminated card type magnetic steering compass visible from vessel’s main steering station. Vessel's compass not illuminated. Make compass satisfactory as per regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 5 September 2023
Resolution: Vsl inactive
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 June 2019 Resolved
Crew members must participate in fire-fighting drills and receive instruction at least once each month. firefighting drills not being conducted or recorded at required interval. Record and conduct fire-fighting drills as required by regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 23 October 2019
Resolution: Provided records
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2019 Resolved
A towing vessel of at least 26 feet, but less than 79 feet, in length must carry a minimum of two lifebuoys located on opposite sides of the vessel where personnel are normally present. Lifebuoys must be at least 610 millimeters (24 inches) in diameter. At least two lifebuoys on a towing vessel greater than 26 feet must be fitted with a floating electric water light approved under approval series 161.010 or 161.110. Appropriate lights are not fitted. Ensure proper electric water lights are available and installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 23 October 2019
Resolution: Lifebuoys provided
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 June 2019 Resolved
Distress signals must be stored in a portable, watertight, brightly colored container marked "DISTRESS SIGNALS" in contrasting letters at the operating station or in a pyrotechnic locker located near the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 5 September 2023
Resolution: Vsl inactive
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 26 June 2019 Resolved
Electrical connections must be suitably installed to prevent them from coming loose through vibration or accidental contact. Device using alligator clips attached to battery terminals. Install electrical connections as to meet regulation and good marine practice.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 23 October 2019
Resolution: Alligator clips removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2019 Resolved
Each towing vessel must be maintained and operated so as to minimize fire hazards. Plastic fuel level gauge on day tank possible source to fuel fire if melted during fire. Make in compliance with regulation and good marine practice.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 5 September 2023
Resolution: Vsl inactive
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2019 Resolved
Propulsion machinery, including shafting, and bearings, must be maintained to ensure proper operation. Any cracking found on the rubber part of the bearing must be replaced prior to the vessel returning to service in 2020. After scope of work has been determined, email this office for review and approval. All workmanship must be cleared by an attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 5 September 2023
Resolution: Vsl inactive
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 20 March 2019 Resolved
An existing vessel may be deemed by the OCMI to be in compliance with 46 CFR Subchapter M provided that the vessel has been both in satisfactory service insofar as structural adequacy is concerned and does not cause the structure of the vessel to be questioned by the OCMI engaged to perform a survey. Forepeak void centerline bulkhead fractured/cut. Have forepeak surveyed and repaired in kind prior to the vessel returning to service in 2020. After scope of work has been determined, email this office for review and approval. All workmanship must be cleared by an attending USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 23 April 2019
Resolution: See attached repair proposal. Satisfactory repairs made with attendance by Marine Inspector.

Casualty record · 3

3 May 2011Routine · role: Involved in a Marine Casualty · activity 4002428
4 May 2011Routine · role: Involved in a Marine Casualty · activity 4002351
3 October 2019Routine · role: Involved in a Marine Casualty · activity 6830525
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.