Records in 2002. Most recent: operational control imposed, 22 September 2002.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
22 September 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1678635
17 September 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1676832
10 September 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1673812
28 June 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1636902
26 June 2002
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1648473
Navigation
Issued 22 September 2002
Resolved
Marine Radar does not operate propely. LEGACY COMPONENT DESC: Marine Radar
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2002
Resolution: Ship provided proper attestation from a technician that all repairs had been made and the radar was working.
Electrical › Electrical Distribution System (service)
Issued 17 September 2002
Resolved
Excessive ground found in the 220V Electric switchboard in phase "R" (SOLAS 74 Ammended II-1 Reg 40.1.3) LEGACY COMPONENT DESC: Ground Detection
Action required: 705 - Other - as specified
Due 17 September 2002
Resolved 21 September 2002
Resolution: Received fax from Class attesting to repairs. Vessel cleared to sail.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 17 September 2002
Resolved
#3 generator leaks. Excessive fuel oil leaks, in the form of spray, from #1 and #2 generators. (Solas 74 Ammended II-1 Reg. 41.1.2 and Reg. I-11(a) and Reg. II-1 Reg. 41.1.1) LEGACY COMPONENT DESC: Nozzle, Injection (fuel injection)
Action required: 705 - Other - as specified
Due 17 September 2002
Resolved 21 September 2002
Resolution: Received fax from Class attesting to repairs. Vessel cleared to sail.
Pollution Prevention/Response › Prevention Equipment
Issued 17 September 2002
Resolved
Oily water separator system is inoperable due to piping arrangements (no overboard discharge). (MARPOL 73/78 Annex 1 reg. 16(4)) LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Due 17 September 2002
Resolved 21 September 2002
Resolution: Received fax from Class attesting to repairs. Vessel cleared to sail.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 September 2002
Resolved
Sounding tube self devices are inoperable throughtout the engine room. Sounding tubes are all broken in the open position. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2002
Resolved 21 September 2002
Resolution: Received fax from Class attesting to repairs. Vessel cleared to sail.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 10 September 2002
Resolved
Improper operations of ship service generator and main engines including excessive oil leaks.
Due 14 September 2002
Resolved 14 September 2002
Resolution: Leaks on ship service generator and main engine fixed and cleaned to the approval of USCG Inspectors.
Lifesaving › Visual Distress Signals (General)
Issued 28 June 2002
Resolved
SARTS to conform to performance standards. Replace to satisfaction of certificate issuing authority. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2002
Resolved 17 September 2002
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 June 2002
Resolved
Repair inoperable secondary radar.
Condition: Unknown
Due 26 June 2002
Resolved 26 June 2002
Resolution: Rec''d service technician''s report attesting to satisfactory repair.