MAURY USCG vessel records Sign in
← All vessels

C HERO

C HERO is a 2002 industrial vessel. The Coast Guard has recorded 27 inspections since 2002, most recently in July 2025, along with 14 deficiencies.

Records from 2002 to 2025. Most recent: inspection, 15 July 2025.

Built
2002
Last inspected
15 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9271705 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDP3837
575925
Flag
UNITED STATES
368530000
Maury page id
psix-575925

Inspections, by type

…with no type recorded1
Years with a record 13 calendar years (2002–2025)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)243.5 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,282 / net 731
ITC dimensions (L × B × D)243.5 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,282 / net 731
BuilderNORTH AMERICAN FABRICATORS LLC · HOUMA, LA, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 March 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2282 - Convention (Subpart B), Gross Ton
731 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP3837MMSI 368530000 · active · compulsorily equipped · granted 17 January 2024, expires 17 January 2034
WDA9706MMSI 369598000 · expired · compulsorily equipped · granted 23 June 2012, cancelled 12 November 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

15 July 2025 Examination of Repairs · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8187207
19 February 2025 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8081115
30 November 2023 ACP Handover Survey · COI Inspection · MTSA/ISPS Verification · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7847225
28 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6223552
9 November 2015 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5766592
10 September 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5718022
2 September 2015 Drydock Exam · Cargo Tank Internal · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5232890
14 September 2011 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4129986
28 October 2010 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3878859
8 October 2010 Administrative Inspection
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 3875301
11 September 2010 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3865860
12 November 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3357882
24 August 2008 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3331575
7 August 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3291567
24 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3246390
15 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3207054
12 July 2007 COI Inspection · MARPOL Annex I Examination · Internal Structural Exam · Cargo Tank Internal · Deficiency Check · MTSA/ISPS Verification · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2993945
7 September 2006 Administrative Inspection · MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2773094
15 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2680424
21 November 2005 Internal Structural Exam · Hull Examination · Cargo Tank Internal · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2535019
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502033
9 September 2005 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2488439
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293927
8 November 2004 MTSA/ISPS Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2246305
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979645
29 October 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1938267
3 September 2002 Inclining Experiment · Initial Certification · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1670192

Deficiency record · 14

Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 10 September 2015 Resolved
Complete all tests required for annual automation test procedures IAW approved PSTPs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 14 September 2015
Resolution: [name withheld] received email with documentation verifying completed automation tests.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 10 September 2015 Resolved
Label CO2 discharge controls in CO2 storage room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 14 September 2015
Resolution: [name withheld] received picture of CO2 controls labeled.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 12 November 2008 Resolved
Perform annual maintenance on engine iaw manufacturer's maintenance requirements. Incorporate scheduled maintenance into maintenance plan.
Due 12 December 2008
Resolved 18 June 2009
Resolution: Maintenance performed and a log created incorporating weekly/quarterly/annual maintenance.
Communications › Public Address System › Loudspeaker
Issued 12 November 2008 Resolved
Demonstrate proper operation of PA/General alarm interrupt iaw SOLAs requirement. The current installation is not acceptable. Current installation requires an additional button to be pushed to de-activate General alarm while PA is being used. The installation is suppose to automatic; in addition, the current installation could prevent General Alarm from sounding if the button is hit accidentall
Due 12 December 2008
Resolved 18 June 2009
Resolution: Vessel meets SOLAS/LSA Code 7.2.1 and 7.2.2 for PA.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 12 November 2008 Resolved
Demonstrate proper operation of guages four Port engine controls at operation station
Due 12 December 2008
Resolved 18 June 2009
Resolution: Gauges were replaced but continue to fail throughout the year and are replaced when found.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 12 November 2008 Resolved
Demonstrate proper operation of Generator overspeed for port generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 12 July 2007 Resolved
Indicators at emergency steering station not functioning.
Due 26 July 2007
Resolved 1 August 2007
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 7 September 2006 Resolved
Demonstrate proper operation of steering failure alarm (inoperative).
Condition: Unknown
Due 6 October 2006
Resolved 14 September 2015
Resolution: Error during MISLE 5.0 transfer
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 September 2006 Resolved
Amend automation test procedures to include steering alarms.
Condition: Unknown
Due 6 October 2006
Resolved 7 September 2006
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 September 2006 Resolved
Service OWS.
Condition: Improper/Lack of Maintenance
Due 6 October 2006
Resolved 15 September 2006
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 September 2006 Resolved
Clear area behind main switchboard.
Condition: Improper/Lack of Maintenance
Due 6 October 2006
Resolved 7 September 2006
Engineering › Fuel Oil Service System › Piping
Issued 7 September 2006 Resolved
Wrap fuel line joints on port/fwd generator
Condition: Improper Installation
Due 6 October 2006
Resolved 7 September 2006
Documentation › Certificates/Documents › IOPP Certificate
Issued 15 June 2006 Resolved
Incorrect official number was listed on vessel IOPP.
Due 15 June 2006
Resolved 15 June 2006
Resolution: Issued corrected IOPP
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 21 November 2005 Resolved
MAKE TWO AFT BALLAST TANKS IN SKEG OPEN FOR INSPECTION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 December 2005
Resolved 31 August 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.