MAURY USCG vessel records Sign in
← All vessels

TOPGUN 80

TOPGUN 80 is a 2002 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2001, most recently in April 2026, along with 53 deficiencies.

Records from 2001 to 2026. Most recent: inspection, 27 April 2026.

Built
2002
Last inspected
27 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG6294
575926
Flag
UNITED STATES
368437000
Maury page id
psix-575926

Inspections, by type

…with no type recorded1
Years with a record 19 calendar years (2001–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)76.8 ft × 20.0 ft × 9.0 ft
Registered tonnagegross 92 / net 74
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Simplified, Gross Ton
74 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP6251MMSI 368437000 · active · compulsorily equipped · granted 31 May 2024, expires 31 May 2034 · licensed under a name not among this hull’s recorded names (not shown)
WDG6294MMSI 368437000 · expired · compulsorily equipped · granted 5 December 2012, cancelled 4 February 2023
WDB2130MMSI 369206000 · expired · compulsorily equipped · granted 25 October 2002, cancelled 29 December 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

27 April 2026 Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8328784
2 March 2026 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8318892
22 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8141395
15 January 2025 Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8071610
2 January 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8056809
18 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7916529
27 July 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7878044
20 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7672170
20 December 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7611477
28 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7439845
11 March 2021 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7155333
22 February 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7144143
18 February 2021 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7142293
2 October 2019 In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6826753
6 March 2019 Annual Inspection · Examination of Repairs · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6637646
7 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6534774
25 October 2017 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6294858
24 April 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6131313
16 February 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6089515
13 September 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5999959
9 March 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5830347
17 March 2014 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4817422
6 April 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3796687
22 December 2008 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3378852
22 May 2008 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3213910
7 November 2007 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3090590
2 November 2007 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3091998
3 October 2007 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3070787
14 February 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2585898
7 November 2005 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2528652
15 March 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2307510
13 October 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1928100
13 December 2002 In-Service Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1718730
26 September 2001 Initial Certification · Construction Oversight · Hull Examination · Inclining Experiment
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1682645

Deficiency record · 53

11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 27 April 2026 Resolved
A vessel over 65ft in length must carry at least one rescue boat unless the OCMI determines they are sufficiently maneuverable and equipped to allow the crew to recover a helpless person. Vessels rescue ladder is rated at 225lbs and should be capable of support one crew member and helpless passenger. Submit plans to be approved by this office for the replacement of the rescue ladder. 46CFR180.210(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 July 2026
Resolution: Received new resuce ladder
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 March 2026 Resolved
A vessel to which this sub-chapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessels COI is expired
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2026
Resolution: Vessel conducted COI inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 May 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's starboard fuel shutoff valve was not operable. Service and prove proper operation to local OCMI.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 May 2025
Resolved 3 June 2025
Resolution: MI attended vessel to conduct test of repaired fuel cut-off. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 January 2025 Resolved
The owner shall make vessel avaible for drydock examinations, internal structural examinations at least once every 2 years if the vessel opeates on saltwater. Vessel drydock 2 year timeframe has elapsed. Conduct drydock prior to conducting operations. 46 CFR 176.600
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2025
Resolution: Vessel conducted Dry-Dock exam. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2024 Resolved
Stations in the maritime service must be licensed by the FCC either individually or by fleet. Station license was expired as of April 2024.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2024
Resolution: Rcvd proof of renewal
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2024 Resolved
Vessels subject to the bridge to bridge act must have a radiotelephone installation. Vessels bridge to bridge certificate was expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2024
Resolution: Rcvd proof of renewal
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2024 Resolved
The vessel is required to have 3 ring buoy's, one of the vessels ring buoy was deteriorated and no longer functional.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: New ring buoy was installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2024 Resolved
Vessels ring buoy should be approved in accordance with 46CFR160.050. Vessels retro reflective tape was deteriorated and no longer functional. Replace retro reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: SOLAS Tape was replaced
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2024 Resolved
All equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The Head pumps were pulling away from the structure it was mounted to, secure head pumps permanently.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 June 2024
Resolution: Rcvd pictures of the structure being reinforced.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 April 2024 Resolved
Integrated smoke detectors were not integrated and did not all set each other off. Troubleshoot and ensure the smoke detectors were integrated.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2024
Resolution: Operator had someone come with us on drills and update the system and reconnect all detectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2024 Resolved
Machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Starboard main had a leak which accumulated approximately 1-1..5 cups of oil in the bilge. Tighten connection to prevent future leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2024
Resolution: Witnessed satisfactory repair.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 April 2023 Resolved
Vessel's engine shut down for the engine room fixed fire fighting system is inoperable. Diagnose the cause of the failure and repair the shut down.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 May 2023
Resolution: Enabled fixed fire to shut down engines
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 20 April 2023 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150°F, must be suitably insulated where necessary to prevent injuries. Turbo chargers on both generators found to not be insulated. Install insulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 25 October 2023
Resolution: Provided report that water cooled turbo is operating as designed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 April 2023 Resolved
Replace expired items in first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 9 May 2023
Resolution: Replaced expired first aid items
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 April 2022 Resolved
Multiple open wires/twist type connectors found in engine space and passenger accommodation space. make joints, splice, or ends with approved connector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2022
Resolved 2 May 2022
Resolution: POC removed two of the wires and made end of the third with an approved connector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 March 2021 Resolved
Each overnight accommodation space on a vessel with overnight accommodations for passengers must be fitted with an independent modular smoke detection and alarm unit in compliance with §181.450. Must provide smoke detection/alarm units in each stateroom for overnight accommodations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2021
Resolved 22 July 2021
Resolution: Installed in all berthing
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 11 March 2021 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Must put a protective covering over the serpantine belt on the port main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2021
Resolved 22 July 2021
Resolution: Guard installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 2 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 October 2019 Resolved
All emergency lighting installed shall operate in upon failure of the main power. Emergency Lighting failed to activate upon loss of main power. Must rectify prior to carrying passengers to the satisfaction of the CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2019
Resolved 2 October 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 October 2019 Resolved
All fire protection equipment must be maintained and tested in accordance with 46 CFR 176.810. Vessel did not have any records available attesting to the most recent maintenance of fire protection. Vessel operator must provide records of all performed maintenance of the vessel fire protection equipment of the past year to the CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2019
Resolved 14 October 2019
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 October 2019 Resolved
All vessel EPIRBs are required to be tested on a monthly basis and logged.
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 October 2019 Resolved
All emergency exits must be properly labeled in accordance with regulations. Provide emergency exit labels on all pop-out emergency exit windows or include information on passenger orientation.
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 March 2019 Resolved
A vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel anniversary date is 01NOV2019. Annual inspection must be conducted between 01AUG and 01FEB. Vessel shall not carry passengers for hire until the annual inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 7 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 November 2018
Resolution: Verified in VIVS.
Navigation › Piloting/Steering › Marine Charts
Issued 1 November 2017 Resolved
Provide current and correct charts for area of operation
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 6 November 2017
Documentation › Logs/Records › Logbook (official)
Issued 1 November 2017 Resolved
Provide logbook
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 6 November 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 March 2016 Resolved
1. The vessel is overdue for required annual inspection. Conduct annual inspection prior to carrying passengers for hire
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 March 2016
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 March 2014 Resolved
Provide FCC Safety Certificate.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2014
Resolution: New FCC Safety Cert provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 17 March 2014 Resolved
Prove proper operation of SSB Radio. IAW 47 CFR 80
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2014
Resolution: Successful radio check was conducted.
Documentation › Logs/Records › Logbook (official)
Issued 17 March 2014 Resolved
Provide ship log format for logging drills, U/W trips and EPIRB tests. IAW 46 CFR 185.728, 185.520, 185.524.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2014
Resolution: Ships log was produced with all required information.
Communications › Radio Communications › EPIRB
Issued 17 March 2014 Resolved
Provide NOAA registration for EPIRB.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2014
Resolution: EPIRB registration was updated.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 March 2014 Resolved
Provide stern light with proper arc. IAW COLREGS
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2014
Resolution: The stern light housing was elevated 12" to allow for full arc of visibility (over the flood light housing that was originally blocking the arc).
Fire Fighting › Fire Pumps › Pressure
Issued 17 March 2014 Resolved
Prove proper operation of the fire pump gauge. IAW 46 CFR 181.300
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2014
Resolution: A new gauge was installed. test sat.
Documentation › Logs/Records › Drug Test Records
Issued 22 December 2008 Resolved
Provide current drug testing documentation as follows: current compliance letter and certificate from consortium, and current random drug testing crew list. No passengers until corrected.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 December 2008
Documentation › Certificates/Documents › Stability Letter
Issued 22 December 2008 Resolved
Post Stability Letter on bridge.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 December 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 December 2008 Resolved
Repair stern light.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 December 2008
Communications › Radio Communications › EPIRB
Issued 22 December 2008 Resolved
Provide current EPIRB NOAA registration, vessel restricted to 3NM until corrected.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 December 2008
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 22 December 2008 Resolved
Mark liferaft hydrostatic release units (HRUs) with proper expiration date (Dec 2010).
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 December 2008
Fire Fighting › Fire Hoses › Condition
Issued 22 December 2008 Resolved
Replace wasted fire hose.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 December 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 December 2008 Resolved
Replace expired medications from first aid kit.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 December 2008
Fire Fighting › Fire Pumps › Casing
Issued 7 November 2007 Resolved
Repair leaking fire pump.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 1 February 2008
Fire Fighting › Fire Pumps › Pressure
Issued 7 November 2007 Resolved
Repair/Replace fire pump guage.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 1 February 2008
Lifesaving › Rocket Parachute Flares › General
Issued 7 November 2007 Resolved
Provide 12 rocket parachute flares.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 1 February 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 November 2005 Resolved
A CURRENT/UPDATED U.S. COAST PILOT IS REQUIRED.
Due 31 December 2005
Resolved 1 December 2005
Resolution: New Coast Pilot purchased.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 November 2005 Resolved
A CURRENT/UPDATED TIDE & TIDAL CURRENT TABLE PUBLICATION IS REQUIRED.
Due 31 December 2005
Resolved 1 December 2005
Resolution: New tide/tidal current table pubs purchased.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 November 2005 Resolved
A CURRENT/UPDATED COAST GUARD LIGHT LIST PUBLICATION IS REQUIRED.
Due 31 December 2005
Resolved 1 December 2005
Resolution: New light list pub purchased.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 November 2005 Resolved
PROVIDE PROOF OF CURRENT ENROLLMENT IN AN APPROVED DRUG TESTING PROGRAM FOR ALL CREWMEMBERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2005
Resolution: PROOF OF CURRENT DRUG TESTING PROGRAM ENROLLMENT PRESENTED & VERIFIED.
Lifesaving › Lifebuoys › Serviceable
Issued 15 March 2005 Resolved
Ensure life rings are orange in color as per 46 CFR 180.70.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 17 March 2005
Resolution: Vsl purchased 2 new life rings.
Construction/Loadline › Structures
Issued 13 December 2002 Resolved
attach capture wires from hatch cover to hull LEGACY COMPONENT DESC: Scuttle
Condition: Improper Installation
Due 4 April 2003
Resolved 3 April 2003
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 December 2002 Resolved
Attach barrier and sign to keep passengers off of upper deck
Condition: Unknown
Due 4 April 2003
Resolved 3 April 2003
Navigation › Piloting/Steering › Marine Charts
Issued 13 December 2002 Resolved
Provide paper charts for operating area.
Condition: Unknown
Due 4 April 2003
Resolved 3 April 2003
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 26 September 2001 Resolved
Demonstrate Fixed fire fighting engine shut down and instillation IAW 46 CFR 162.465
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2002
Resolved 8 November 2002
Resolution: Tested to the satisfaction of the attending.
Stability › Incline Test
Issued 26 September 2001 Resolved
Post Stability Letter upon reciept LEGACY COMPONENT DESC: Letter
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 November 2002
Resolved 8 November 2002
Resolution: Letter received and posted.

Ownership record