MAURY USCG vessel records Sign in
← All vessels

KOGIA

KOGIA is a 2000 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2000, most recently in May 2026, along with 26 deficiencies and 1 operational control.

Records from 2000 to 2026. Most recent: inspection, 18 May 2026.

Built
2000
Last inspected
18 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ7559
Flag
UNITED STATES
—
Maury page id
psix-5763

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (2000–2026)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it2 - Regulatory (Subpart C or D), Net Ton
2 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

18 May 2026 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8352893
28 May 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8130767
19 December 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8034921
31 January 2024 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7858552
8 May 2023 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7683427
14 December 2022 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7609410
8 June 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7470807
8 June 2021 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7176723
9 December 2020 Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7103597
21 May 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6957017
28 March 2019 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6652137
20 March 2019 COI Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6642313
12 December 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6589015
22 March 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6376943
17 April 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6136142
30 December 2016 Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6063998
14 March 2016 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5833128
27 March 2014 Hull Examination · COI Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4820319
18 March 2010 Hull Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3694819
26 March 2009 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3440381
20 March 2008 Hull Examination · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3173121
15 March 2007 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2888019
16 May 2006 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 2650691
15 March 2006 Annual Inspection · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2606528
22 March 2005 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2310357
25 February 2004 Hull Examination · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2013422
25 March 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1762668
26 February 2002 Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1489222
12 April 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1417256
20 April 2000 Initial Certification · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1395419

Deficiency record · 26

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 May 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 06 lifejackets onboard found unserviceable. Replace 06 lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 5 June 2023
Resolution: Received picture of new lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2020 Resolved
A number of child size life jackets equal to 10% of the number of persons permitted on board must be provided. Vessel missing one child size life jacket. Provide child size life jacket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 22 May 2020
Resolution: Received photo documentation of new child life
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 May 2020 Resolved
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Vessel must provide an up-to-date chart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 22 May 2020
Resolution: Received photo documentation of new chart
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 March 2019 Resolved
Vessel required 6 red and 6 orange distress flares. Vessel only has 8 day/night flares. Vessel required to have 12 total. Vessel restricted to LAKES, BAYS, AND SOUNDS until it meets requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2019
Resolved 20 March 2019
Resolution: Vessel owner purchased the missing flares and has the required amount on board.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 20 March 2019 Resolved
First Aid kit must be carried on vessel under approval series 160.041. Vessel has Aspirin which has a expired date. Replace aspirin with non expired product.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2019
Resolved 20 March 2019
Resolution: Vessel owner has purchased and place the new aspirin bottles on board vessel.
Lifesaving › Hand Flares › Quantity
Issued 22 March 2018 Resolved
Only 08 red flares are onboard. limited to Lakes/Bays/Sounds until 04 add'l red flares or orange smokes are provided.
Action required: 705 - Other - as specified
Resolved 15 May 2018
Resolution: Recieved Cert
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 March 2018 Resolved
Label work vest storage to distinguish from PFD storage. Correct within 07 days.
Action required: 705 - Other - as specified
Due 8 May 2018
Resolved 15 May 2018
Resolution: Cleared
Communications › Radio Communications › EPIRB
Issued 22 March 2018 Resolved
Conduct and document monthly EPIRB tests.
Action required: 10 - Deficiency Rectified
Resolved 1 May 2018
Resolution: Master will add EPIRB testing to monthly drills check-list.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 March 2018 Resolved
Life ring light battery is expired. Replace batter & re-mount life ring in vicinity of light storage prior to night operation.
Action required: 705 - Other - as specified
Resolved 15 May 2018
Resolution: Repalced Batery
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 March 2018 Resolved
Provide valid Marine Radio Operator Permit. Provide valid FCC Safety Certificate. Provide valid FCC Station License. Vessel limited to not more than 1000 feet from land.
Action required: 705 - Other - as specified
Resolved 15 May 2018
Resolution: FCC Cert's complete
Construction/Loadline › Hull › Stiffener
Issued 27 March 2014 Resolved
Attending inspectors noted delamination of FRP IWO bow cap (port & starboard)
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Construction/Loadline › Hull › Stiffener
Issued 27 March 2014 Resolved
Attending inspectors noted FRP delamination IWO tranverse framing under side/deck caps (port & starboard)
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 27 March 2014 Resolved
Attending inspectors noted broken lens IWO forward deck light (located on t-top rail)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 March 2014 Resolved
Attending inspectors noted floating waterlight battery required replacement (annual requirement)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Engineering › Fuel Oil Service System › Hose
Issued 27 March 2014 Resolved
Attending inspectors noted improper fuel lines IWO portable fuel system. Owner/operator to provide suitable replacement fuel lines that meet SAE J-1942 or equivalent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 March 2014 Resolved
Attending inspectors noted fractured/broken bracket IWO remote fuel shut-off valves for emergency fuel shut-off.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 March 2014 Resolved
Attending inspectors noted emergency fuel shut-off valve assembly was not properly marked with operating instructions.
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 27 March 2014 Resolved
Attending inspectors noted that vessel does not carry two (02) portable lights.
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 27 March 2014 Resolved
Attending inspectors noted that trim/tilt control switch @ helm was inoperable at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2014 Resolved
Attending inspectors noted dead ended wiring IWO electronics console (@ t-top)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 27 March 2014 Resolved
Attending inspectors noted vessels current registration has expired.
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Navigation › Piloting/Steering › Marine Charts
Issued 27 March 2014 Resolved
Attending inspectors noted that vessel does not carry required navigation publications, i.e.: Coast Guard Light List, Inland navigation rules, Tide & Current Tables, Coast Pilot and marine charts for areas transited.
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 March 2014 Resolved
Vessel's FCC Radio Station Authorization certificate is not up to date (reflecting new owner).
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 27 March 2014 Resolved
Attending inspectors noted vessel not equipped with B:C 1 portable extinguisher at helm.
Action required: 705 - Other - as specified
Due 15 April 2014
Resolved 7 May 2014
Documentation › Manuals/Policy Documentation
Issued 25 February 2004 Resolved
PROVIDE PROOF OF DAPI ENROLLMENT.
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 26 February 2004
Resolution: CG SPOKE WITH PROFFESSIONAL NURSING TO CONFIRM ENROLLMENT.
Documentation › Manuals/Policy Documentation
Issued 25 February 2004 Resolved
PROVIDE COPY OF NAVIGATIONAL RULES.
Action required: 705 - Other - as specified
Due 26 March 2004
Resolved 26 February 2004
Resolution: OWNER PURCHASED COPY FROM LOCAL MARINE SUPPLIER.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.