Records from 2002 to 2012. Most recent: inspection, 26 January 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 January 2010
Resolved
Housing and lenses for starboard side light found cracked, broken from its foundation, and temporarily repairs. Light fixture to be replaced and proper operation demonstrated prior to departure from port. Report cleared via E-mail dated 27 Jan 10, Item remains open until confirmed during next CG attendance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 24 February 2010
Resolution: [name withheld] Confirmed corrected status in late Feb.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 January 2010
Resolved
Navigation light indicator panel indicating failure of lower light filaments for side lights and stern light as well as for the not-under-command lights. Restore operational readiness and prove proper operation of all navigational lights prior to departure from port. Report cleared via E-mail dated 02 Feb10, Item remains open until confirmed during next CG attendance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2011
Resolved 20 January 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 January 2010
Resolved
Vessel's stern light lens, upper filament, found cracked with temporary repairs (epoxy). Lens to be replaced as original within 60 days, March 22, 2010. Report cleared via E-mail dated 02 Feb10, Item remains open until confirmed during next CG attendance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 24 February 2010
Resolution: [name withheld] Confirmed corrected status in late Feb.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 20 January 2010
Resolved
Proved proof of the fire detection system has be tested and is fully operational prior to departure from port. Report cleared via E-mail dated 29 Jan10, Item remains open until confirmed during next CG attendance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 24 February 2010
Resolution: [name withheld] Confirmed corrected status in late Feb.
Communications › Radio Communications › EPIRB
Issued 20 January 2010
Resolved
Documentation and EPIRB placard to be provided on board prove compliance within 30 days, February 23, 2010.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 22 February 2010
Resolution: [name withheld] Confirmed corrected status in late Feb.
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 20 January 2010
Resolved
Vessel found not in compliance with LRIT. While vessel is less than 300 GRT a USCG policy determination had deemed the tonnage to be used in determining applicability for LRIT as 300 or more GT ITC for vessels which make international voyages. Vessel to install an approved LRIT system and prove compliance within 30 days, February 23, 2010. Report cleared via E-mail dated 29 Jan10 Item remains open
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 24 February 2010
Resolution: [name withheld] Confirmed corrected status in late Feb.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 20 January 2010
Resolved
Provide updated compass deviation card for magnetic compass within 30 days, February 23, 2010. Report cleared via E-mail dated 25 Feb10, Item remains open until confirmed during next CG attendance.
Action required: 705 - Other - as specified
Due 23 February 2010
Resolved 22 February 2010
Resolution: [name withheld] Confirmed corrected status in late Feb.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 20 January 2010
Resolved
Supply proof of MDEs and SSGs alarms have been tested. Report cleared via E-mail dated 30 Jan10, Item remains open until confirmed during next CG attendance.
Action required: 705 - Other - as specified
Due 19 January 2011
Resolved 20 January 2011
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 20 January 2010
Resolved
Provide on board two SCBAs, with the required spare charges, prior to carrying cargoes requiring said equipment. Report cleared via E-mail dated 19 Feb10, Item remains open until confirmed during next CG attendance
Action required: 705 - Other - as specified
Due 19 January 2011
Resolved 20 January 2010
Lifesaving › Rescue Boat › Boarding Ladder
Issued 24 January 2009
Resolved
Vessel does not have a rescue boat or an operation rescue platform. Vessel is to conduct five underway rescue boat drills on seperate days. Report cleared via E-mail dated 01Feb09, Item remains open until confirmed during next CG attendance.
Action required: 705 - Other - as specified
Due 19 October 2009
Resolved 17 January 2010
Resolution: Sighted drilll records.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 January 2008
Resolved
Repair all main engine exhaust (weld seams in way of water cooling.) Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Communications › Public Address System › Loudspeaker
Issued 17 January 2008
Resolved
Prove proper operation of the PA system. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 January 2008
Resolved
Replace line on lifrings, properly attach water light and throw line. Replace corroded clip on water light. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Communications › Radio Communications › EPIRB
Issued 17 January 2008
Resolved
Register EPIRB and mark battery expiration date. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Communications › Radio Communications › EPIRB
Issued 17 January 2008
Resolved
Mount EPIRB in float free position.
Due 24 January 2008
Resolved 17 January 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 17 January 2008
Resolved
Provide proper operating sound power phone in way of emergency steering contols.
Due 20 April 2008
Resolved 17 January 2008
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 17 January 2008
Resolved
Repair crakc in main engine lube oil tank. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Lifesaving › Inflatable Liferafts › Markings
Issued 17 January 2008
Resolved
Replace launching instructions for inflatable rafts. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Fire Fighting › Fixed Fire Detection System › Manually Operated Call Points
Issued 17 January 2008
Resolved
Replace manual fire pull in way of main entrance. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 17 January 2008
Resolved
Adjust rudder angle indicators (bridge, engine room.) Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 January 2008
Resolved
Properly stow spare batteries. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 January 2008
Resolved
Provide proper battery boxes for batteries in the generator room. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Engineering › Diesel Engine (auxiliary) › Bearing
Issued 17 January 2008
Resolved
Repair leaking seal in port side generator. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Engineering › Fuel Oil Service System › Piping
Issued 17 January 2008
Resolved
Replace fuel line on stbd side generator. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 17 January 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 17 January 2008
Resolved
Replace motor in port side fwd fan in the engine room. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Communications › Alarms/Indicators › Fire Alarm
Issued 17 January 2008
Resolved
Engineer permanent solution to keep alarm panel cool and in good operational condition. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Lifesaving › Hand Flares › Storage
Issued 17 January 2008
Resolved
Provide water tight container for distress signals. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 17 January 2008
Resolved
Update all charts and chart log and provide most recent notice of mariners. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 17 January 2008
Resolved
Chain and lock the overboard discharge valve ot prevent any discharge of oil from the oily water separator.
Due 20 April 2008
Resolved 17 January 2008
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 17 January 2008
Resolved
Create and maintain a lifesaving equipment maintenance record in accordance with 46 CFR 185.702. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 January 2008
Resolved
Repair rail and fire damper damage on aft main deck. Received E-mail dated May 14, 2008 from Master stating that CG-835 has been completed. Extended due date to correspond with annual window due date.
Due 19 January 2009
Resolved 24 January 2009
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 17 January 2008
Resolved
Renew holed flame screens on port side fuel vents.
Due 20 April 2008
Resolved 17 January 2008
Fire Fighting › Fire Hydrants › Material
Issued 19 October 2006
Resolved
Provide proper spanner wrench for fire station #2.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 October 2006
Resolved
Install operational smoke detector on the main deck, passenger space.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 19 October 2006
Resolved
Renew holed flame screen on the fuel vent stbd side aft. Item reported cleared via E-mail dated 21NOV06 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 19 January 2008
Resolved 17 January 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 October 2006
Resolved
Service 4 fire extinguishers with missing seals on the pins.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 October 2006
Resolved
Create and maintain a lifesaving equipment maintenance record in accordance with 46CFR185.702. Item reported cleared via E-mail dated 21NOV06 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 17 January 2008
Accommodation/Occupational Safety › Ventilation › General
Issued 19 October 2006
Resolved
Replace the fan on the galley stove.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Navigation › Piloting/Steering › Marine Charts
Issued 19 October 2006
Resolved
Provide updated charts & notice to mariners. Item reported cleared via E-mail dated 21NOV06 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 17 January 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 October 2006
Resolved
Install corrosion resistant clips on the lines between the ring life buoy and water light.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 October 2006
Resolved
Replace the broken globe in the emergency light in way of the liferafts on the port side. Item reported cleared via E-mail dated 21NOV06 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 17 January 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 19 October 2006
Resolved
Review and update the fire control plan to reflect the fire extinguishing and lifesaving equipment onboard the vessel, including but not limited to: remove the life floats, add life rafts, add the fire extinguisher in the paint locker, add life jackets in staterooms.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 19 October 2006
Resolved
Post an emergency broadcast placard. Issued in error.
Due 19 October 2006
Resolved 19 October 2006
Resolution: Issued in error, the placard was in place.
Communications › Internal Communications System › Sound-powered Telephone
Issued 19 October 2006
Resolved
Prove proper operation of the sound powered phone in the steering gear room. Item reported cleared via E-mail dated 21NOV06 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 17 January 2008
Fire Fighting › Fire Pumps › Pressure
Issued 19 October 2006
Resolved
Replace inop pressure gage on both fire pumps. Item reported cleared via E-mail dated 21NOV06 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 17 January 2008
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 19 October 2006
Resolved
Properly test low lube oil pressure alarms and shutdowns on all main diesel engines and generators, and provide a report to the OCMI.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Communications › Alarms/Indicators › High Water Alarm
Issued 19 October 2006
Resolved
Properly test high jacket water temperature alarms on all main diesel engines and generators and provide a report to the OCMI.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 17 January 2008
Lifesaving › Inflatable Liferafts › Markings
Issued 19 October 2006
Resolved
Properly label vessel information on the identification card on all 4 liferafts. Item reported cleared via E-mail dated 21NOV06 and shall remain open until verified to be corrected by attending USCG Marine Inspector
Action required: 705 - Other - as specified
Due 21 January 2008
Resolved 17 January 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 19 October 2006
Resolved
Remove SOLAS lifejackets that are not USCG approved.
Action required: 705 - Other - as specified
Due 19 October 2006
Resolved 19 October 2006
Resolution: Lifejackets were removed while the inspectors were onboard. There were enough extra CG approved lifejackets to maintain the proper number.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 February 2006
Resolved
SECURE OVERBOARD DISCHARGE ON THE OWS TO ENSURE IT IS NOT USED UNTIL OIL CONTENT METER IS INSTALLED. OWS MUST MEET MARPOL REQUIREMENTS. MASTER SENT EMAIL STATING IN COMPLIANCE WILL LEAVE OPEN UNTIL NEXT INSPECTION
Action required: 705 - Other - as specified
Due 1 February 2007
Resolved 19 October 2006
Resolution: Verified that the overboard discharge from the OWS is secured.
Documentation › Certificates/Documents › FCC SSL
Issued 1 February 2006
Resolved
ENSURE NEW OR AMENDED FCC LICENSE IS ON BOARD SHOWING THE NEW INSTALLATION OF THE GMDSS.
Due 15 February 2006
Resolved 16 February 2006
Resolution: Received email from FCC rep stating license was valid. See scanned email
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 27 January 2005
Resolved
001. Have fixed CO2 bottles system weighed and provide the list to OCMI no later than 9 Feb 2005
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2005
Resolved 28 February 2005
Resolution: Corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 November 2004
Resolved
Remove SOLAS smoke/light from ring buoy and attach a CG approved light on one ring buoy attach line on one. Relocate third ring buoy to be ready accessible with cargo onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2005
Resolved 9 February 2005
Resolution: Corrected
Lifesaving › Launching Appliances › Davit
Issued 5 March 2004
Resolved
submit and have plans approved for the port davit installation. davit to be inspected/tested before placing in operation. inspection and test witnessing to be conducted by ABS suveyor or CG marine inspector.
Due 15 April 2004
Resolved 27 January 2005
Resolution: Witness Satisfactory Weight test and sighted approved plans.
Engineering › Steering Gear System › Power Unit
Issued 5 March 2004
Resolved
existing steering system modified by the installation of a Dynamic Positioning system. Submit and have plans approved for DP modifications and have approved system operation witnessed by CG inspector or ABS surveyor prior to operating steering system. ok to proceed to Texas/tow to Nigeria as is.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 April 2004
Resolved 27 January 2005
Resolution: Sighted approved DP system from G-MSE with note requiring to do a total loss of power failure and no loss of propulsion control. Conducted total blackout and no loss of propulsion was noted also switched numerous times between DP mode and normal Propulsi
Construction/Loadline › Hull
Issued 5 March 2004
Resolved
submit and have plan approved for towing eye welded to hull iwo bow/stem LEGACY COMPONENT DESC: Bracket
Due 15 April 2004
Resolved 21 April 2004
Resolution: plan review not required by MSC provided no passengers on board during tow.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 August 2002
Resolved
Resubmit fixed CO2 piping layout to the MSC for approval. LEGACY COMPONENT DESC: Piping
Due 29 November 2002
Resolved 4 November 2002
Resolution: MSC ltr E1-0203737 dtd Nov 4, 2002: selected nozzels meets requirements and calculations do not require resubmission.