Records from 1994 to 2025. Most recent: inspection, 5 March 2025.
Documentation record
Registered dimensions (L × B × D)88.5 ft × 18.5 ft × 11.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAKE UNION DRY DOCK · SEATTLE, WA, UNITED STATES · built 1928
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 21 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
5 March 2025
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088933
13 June 2005
Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2388770
9 September 2004
Examination of Repairs
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2191302
3 October 2002
Examination of Repairs · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1683779
17 September 2001
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1073317
12 September 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1460570
9 March 2000
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1046989
29 September 1999
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1423261
29 July 1999
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1440291
4 November 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1420015
15 September 1998
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 798723
16 September 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1111423
30 May 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1108126
9 December 1996
Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1093342
27 September 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 833196
25 October 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 884244
5 July 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 882055
2 June 1995
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 876393
2 June 1995
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 880789
16 May 1995
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1358756
13 April 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 846759
6 April 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 840985
22 December 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1154515
10 November 1994
Hull Examination · Initial Construction-Excluding Oversight · Plan Review "T" Boat · Inclining Experiment
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1179955
10 November 1994
Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1396199
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side recaulk along the garboard strake.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, Second plank down from the rub rail repair/replace plank
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, first plank down from rub rail repair/replace plank.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, up forward, second plank from rub rail replace the plank.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, near first thru-hull fitting, sixth plank down from the rub rail, replace planking.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, area before first thru-hull replace eighth and ninth planks down from rub rail.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, approx. 2.5 feet back from the bow, replace third plank down from the rub rail.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, approx. four feet back from bow replace the nineth plank down from rub rail.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, repair wood around the fourth window from the bow.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Port side, near the bow replace the third, fourth, and eleventh plank down from the rub rail.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Port side, directly above the bow thruster, replace the third, fourth, fifth, and tenth plank down from the rub rail.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Port side, amidships, replace the third plank down from the rub rail.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Port side, back aft, replace the second and the third plank down from the rub rail.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Port side, back aft remove butt block at the third plank down from rub rail, to examine the condition of the wood.
Action required: 705 - Other - as specified
Resolved 5 November 2002
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Port side, replace second and third plank up from the keel.
Action required: 705 - Other - as specified
Resolved 17 October 2002
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Port side, replace fifth plank up from the keel.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Construction/Loadline › Hull
Issued 16 October 2002
Resolved
Stbd side, replace second and third plank up from the keel.
Action required: 705 - Other - as specified
Resolved 17 February 2003
Engineering
Issued 13 April 1995
Resolved
REMOVE PLASTIC DRAIN COCK FROM FUEL FILTER AND REPLACE WITH METAL PLUG OR CAP.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Engineering
Issued 13 April 1995
Resolved
INSTALL PROPER SUPPLY DUCT TO VENTILATE ENGINE SPACES. ALSO PROVIDE VENT DUCT FROM BILGE SPACES TO EXHAUST DUCT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Engineering
Issued 13 April 1995
Resolved
INSTALL METAL HEAT DEFLECTOR BOWLS BELOW RACOR FUEL FILTERS TO PORT AND STARBOARD GENERATORS.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 10 November 1994
Resolved
PROVIDE PROTECTIVE COVERS/GLOBES FOR THE ELECTRICAL LIGHTING FIXTURES IN THE BELOW-DECK LOUNGE AFT OF THE ENGINEROOM. (EXPOSED LIGHT BULBS ARE NOT ACCEPTABLE ON A PERMANENT BASIS.)
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Unknown
Issued 10 November 1994
Resolved
PRIOR TO COMPLETION OF THE NEXT ROUTINE DRYDOCKING, PROVIDE THE DRAFT MARKSOR LOADING MARKS REQUIRED BY 46 CFR 185.30-3(B). ENSURE PLACEMENT OF THE MARKS IS CONSISTENT WITH APPROVED STABILITY CALCULATIONS.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Unknown
Issued 10 November 1994
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE COMPLIANCE WITH THE CHEMICAL (DRUG) TESTING REQUIRMENTS OF 46 CFR 16. THIS INCLUDES BUT IS NOT LIMITED TO: CREW TRAINING, PRE-EMPLOYMENT TESTING, AVAILABLE HOTLINE TELEPHONE NUMBER AND EXISTENCE OF A RANDOM TESTING PROGRAM.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994
Construction/Loadline
Issued 10 November 1994
Resolved
PRIOR TO OPERATING ON PARTIALLY-PROTECTED WATERS, AS DEFINED BY THE [name withheld] OF SPECIAL SECURING DEVICES FOR THE OPENING PORTLIGHTS IN THE ENGINEROOM AND THE BELOW-DECK LOUNGE AFT OF THE ENGINEROOM.
Condition: Unknown
Due 10 November 1994
Resolved 10 November 1994