03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 10 May 2023
No resolution recorded
Valves and thru hull fittings are to be in good working condition and have ability to close and remain water tight and operate is intended at all times.
Thru hull raw water suction for the MSD is leaking continual. Repair or replace valve.
46 CFR 177.300
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 March 2023
No resolution recorded
REPAIR BILGE PUMPS: A VESSEL MUST BE PROVIDED WITH BILGE PUMPS IN ACCORDANCE WITH TABLE 182.520(a)(e). AT TIME OF INSPECTION MACHINERY SPACE BILGE PUMPS DID NOT OPERATE.
46 CFR 182520(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 March 2023
No resolution recorded
PROVIDE PROPER CABLE TIES: Cable and Wiring must be installed with metal supports and spaced not more than 24” apart in such a manner to avoid chaffing and other damage. Plastic tie wraps are limited to bundling and not support.
46CFR 183.340 (b) (4)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 March 2023
Resolved
Secure batteries and battery boxes: code Each battery must be located as high above bilge as practicable, secured to protect against shifting with roll and pitch of vessel and free from water splash or spray
46CFR 183.352 (b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 March 2023
Resolved
Provide lanyard for life ring light and attach to life ring: Each ring life buoy with floating water light must have a lanyard 3 feet in length but not more than 6 feet securing light around the body of the ring life buoy (3) Each floating water light on a vessel carrying only one ring buoy, must be attached to a lanyard with a corrosion resistant clip. A break strength of at least 50 pounds that can be quickly disconnected.46CFR10.70 (6)(d)(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 March 2023
No resolution recorded
Provide repair schedule for repairing as origional construction:
-main deck plank replacement and beam repair aft of main engine including port carlins, from embarcation to stern.
-Repair/Replacement of deck house sheathing of rotted areas around operating station to include kitchen area aft of operating station.
-Repair /Replacement of operating station rotten windows and window frames
-Repair/Replacement of of rotten operating station roof to prevent water intrusion.
The listed required repairs are to be completed no later than 31 March 2024. A list of materiels and repair schedule is to be provided to cognizant OCMI pror to commencing work. (completed Repairs must be to satisfaction of cognizant OCMI and undergo a satisfactory sea trial prior to operation with passengers.)46 CFR 177.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 March 2023
No resolution recorded
Repairs and alterations to hull, machinery, or equipment that affects the safety of the vesselmust not be made without the approval of cognizant OCMI.
-Replace / Repair as origional dunnage boards IWO Fore Peak, Main Hold and Machinery Space.
-Arrest fungus and moldIWO fore peak, and main hold under sides of recently installed / replaced deck beams and planks.
-Repair as origional fore peak deck beam IWO rot on starboard side.
Provid Plan to install access hatch for main hold. The deck was recently replaced and no approved hatch installed. Repairs and approved hatch install to be completed prior to 31 March 2024.
Condition: Improper Installation
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 21 March 2023
Resolved
Service Life floats: AT TIME OF INSPECTION LIFEFLOATS WERE NOT SERVICED AND NOT IN ACCEPTABLE CONDITION FOR OPERATION IAW COI. A life float approval series 160.027 or other standard specified by commandant. In good serviceable condition. In Accordance with 46CFR180.15 (d) & 180.207 (a) (1) Lakes, Bays ad Sounds: wood vessels in cold water are required LF with 100% aggerate capacity, 46CFR180.207 2 (c) A vessel on L,B & S route in Warm Water is not required to carry survival craft. 46CFR180.207 (2) (d)A vessel certificated to operate on L,B & S route within one mile of land is not required to carry survival craft.
Service life floats and lights for life floats.
46CFR180.200 (a) (2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2023
Resolution: VSL OPERATES WARM WATER MONTHS ONLY A vessel on L,B & S route in Warm Water is not required to carry survival craft. 46CFR180.207 (2) (d)A vessel certificated to operate on L,B & S route within one mile of land is not required to carry survival craft.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 June 2022
No resolution recorded
46 CFR 182.720(e)
Where flexible nonmetallic hose is permitted for use in piping systems by theis section, it must meet SAE J-1942 or be specifically approved by the Commandant. Vessel supply, return and vent hoses were not required J-1942 hoses.
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 June 2022
No resolution recorded
46 CFR 182.20-40(b)(3)
The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. Vessel stbd fuel tank remote shutoff valve was inoperable. Vsl only allowed to operate off of port fuel tank until repaired.
Action required: 705 - Other - as specified
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 June 2022
No resolution recorded
46 CFR 182.20-30(d)
When the flexible section is a nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Install bonding wire on stbd fill pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 June 2022
No resolution recorded
Provide Repair Proposal detailing continuation of deck plank repair and beam repair including carlins, port & starboard from embarcation to stern,Deck House Sheathing repair aft of operating station, Weather seal and sash repair to kitchen area windows, roof repair and recovering to prevent water intrusion. To include any materials used and construction application.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Prep exposed fasteners heads in hull with proper "bungs" including fastener heads improperly sealed.
46 CFR 177.300
NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Re-seal rabbit seam at the keel the length of the vessel.
46 CFR 177.300
NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Reef/Re-caulk and re-seal side planks port and starboard from plank 29 to stern Chine to Sheer.
46 CFR 177.300
NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Remove Copper covering from planks 36&37 and properly seal planks to prevent water intrusion.
46 CFR 177.300
NVIC 7-95
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 April 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 April 2022
Resolved
Seal machinery space to provide proper enclosure to prevent FFF from escaping when discharged.
Fire damper closures do not operate or close effectively. The openings and surrounding area of superstructure have rot and wastage preventing closures to work properly
46 CFR 177.300, 181.400, NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2022
Resolved
Provide proper junction box for shore tie connection.
46 CFR 183.390
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 April 2022
Resolved
Repair / repalce Life Jacket lockers.
Storage lockers rotten and broken.
46 CFR 177.300/ 180.78
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Repair firring IWO main Mast base and re-set mast base bolts.
46 CFR 177.300
NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Properly seal natural vent piping foreward and aft on main deck to prevent water intrusion.
46 CFR 177.300
NVIC 7-95
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 June 2022
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 18 April 2022
Resolved
Provide plan for approval to replace deck house windows IWO rot , missing window and rot IWO frames.
46 CFR 177.300 / 46 CFR 190.02
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 March 2023
Resolution: Pending. Proposal continued to be completed after end of 2022 season.Partial completion. Re-issued in activity 7654657
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Provide Plan Approval to repair as origional the anchoring eye bolt holding steering pully. Plan to include proper support of of beam and support cleared of rot.
46 CFR 178.814 / 177.300
NVIC 7-95
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 18 April 2022
Resolved
Seal deck Clamp as origional at deck clamp at sheer to prevent water intrusion.
46 CFR 177.300
NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 April 2022
Resolved
Provide repair plan for approval to install proper hatch in main deck fwd of mast. Unauthorized cut out to install hatch was not accepted by attended inspector.
46 CFR 177.300
NVIC 7-95
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
Resolution: Non - Approved Hatch Project abandoned. Deck repaired as close to origional as possible.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 April 2022
Resolved
Provide Plan for approval to repair main hold hatch to include rotted adajacent deck beams and fore and aft carlins. Unauthorized repair and hatch covering install was not accepted by attending inspector
46 CFR 177.300
NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 March 2023
Resolution: Deck Planks repaired. Hatch Install Pending.Partial completion. Re-issued in activity 7654657
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Provide plan for approval to replace fungus infested and rotten deck boards and deck beams IWO fore peak, main hold, machinery spcae, pilothouse, kitchen area and aft of kitchen above transom.
46 CFR 177.300
NVIC 7-95
Action required: 705 - Other - as specified
Resolved 22 March 2023
Resolution: Deck Planks replaced from bow up to embarcation point. Deck sealed rest of way to stern top side. Remaining work to be completed after 2022 season.Partial completion. Re-issued in activity 7654657
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 April 2022
Resolved
Provide plan for approval to repair / replace as origional dunnage boards IWO fore peak, main hold, machinery space.
46 CFR 177.300
NVIC 7-95
This requirement to be completed by end of calendar year 2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 March 2023
Resolution: Work to be completed after 2022 season.
Partial completion. Re-issued in activity 7654657
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 April 2022
Resolved
(a) The owner or managing operator shall make a vessel available for dry dock, underwater examination or internal structural examination.
In accordance scheduled intervals and NVIC 7-95 guidance wood vessels are to undergo a routine inspection of fasteners. Vessel scheduled fastener pull was due by 31 March 2022. An initial scheduled date of 01 April 2022 was canceled due to vessel not out of water and made ready for fastener examination.
The vessel is restricted from carrying passengers until the fastener examination can be completed.
Officer in Charge Marine Inspection (OCMI) can provide a extension to the examination interval.
A written request to [name withheld] requesting an extension is required.
46 CFR 176.610(a), 46 CFR 176.675, NVIC 7-95
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2022
Resolution: Fastener Pull Completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 April 2022
Resolved
Repair/replace as origional rotten hand rails IWO port & starboard from stem to embarcation ports.
46 CFR 177.300 / 46 C FR 177.900
NVIC 7-95
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be serviceable condition must be repaired or replaced. Aft port and starboard life buoys found in unserviceable condition, including dry-rotted grab lines.
46 CFR 176.808(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 27 March 2021
Resolution: Aft life ring buoys removed from service.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2021
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment under all practical conditions. Discharge piping for starboard bilge pumped cracked and returning water back to bilge after pumping.
46 CFR 182.25-1 (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 7 April 2021
Resolution: Stbd bilge pump discharge hose renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 March 2021
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Operating station indicator light was inoperable for the starboard automatic bilge.
46 CFR 182.530(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 27 March 2021
Resolution: Indicator light replaced on STBD automatic bilge pump indicator at operating station.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 3 March 2021
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. All alcohol testing strips on board the vessel were expired.
46 CFR 185.212
46 CFR 4.06-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 27 March 2021
Resolution: Alcohol strips renewed. Expiration 2022.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 March 2021
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. First-aid kit contents expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 27 March 2021
Resolution: First aid kit renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2021
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Battery for floating waterlight attached to starboard ring buoy found expired.
46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 March 2021
Resolved 16 April 2021
Resolution: New Raycor No 945 batteries purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2021
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.01 and be applied as specified by IMO Resolution A.658(16), which requires application around or on both sides of the body of the lifebuoy at four evenly-spaced points. Retroreflective material is missing from two points on the forward life buoy.
46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 27 March 2021
Resolution: Life ring buoy adequately affixed with retrorelfective material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2021
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring buoy. Floating waterlight lanyard was approximately 1 foot in length after being secured around the body of the ring buoy.
46 CFR 180.70(d)(2)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 27 March 2021
Resolution: water light lanyard elongated and affixed around body.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 March 2021
Resolved
All cable and wire must be installed with metal supports spaced not more than 24" apart and in such a manner as to avoid chafing and other damage. Stern light wiring in lazarette improperly supported by failed plastic 3M wire ties instead of metal supports every 24".
46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 March 2021
Resolved 27 March 2021
Resolution: Wiring in lazarette supported.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 March 2021
Resolved
A vessel on lakes, bays, and sounds or rivers must carry 3 hand red flare distress signals approved to 46 CFR 160.021 and 3 hand orange smoke distress signals approved to 46 CFR 160.037, with substitutions as authorized in 46 CFR 180.68(c). Distress signals found expired or of a type approved for recreational vessel under 33 CFR 175.110.
46 CFR 180.68(b)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 3 March 2021
Resolved 3 March 2021
Resolution: 6 new red hand flare distress signals purchased and placed onboard the vessel prior to completion of the inpection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 November 2020
Resolved
REPAIRS OR ALTERATIONS TO THE HULL, MACHINERY, OR EQUIPMENT INCLUDING REPAIRS OR REFASTENING OF DECKS, FRAMES, INTERNAL STRUCTURAL MAMBERS, RIGGING MUST NOT BE MADE WITHOUT APPROVAL OF THE COGNIZANT [name withheld] FOR THE FOLLOWING ITEMS TO INCLUDE LONG RANGE PLANS TO ARREST / REPAIR ROT, MOLD AND FUNGUS GROWTH THROUGH THE VESSEL.
1. ROTTEN DECK BOARDS IWO AFT & FWD OF MAST.
2. ROTTEN DECK PLANKING BETWEEN DECK HOUSE AND FWD HOLD.
3. ROTTEN AREAS IWO PORT & STARBOARD SIDE OF DECK HOUSE
IN VICINITY OF VENTILATION SHUDDERS.
4. DECK HOUSE MOUNTING TRIM IWO DECK HOUSE PLATE ATTACHMENT INCLUDING DECK BOARD BELOW SAME.
5. ROT ON DECK HOUSE SUPPORT BEAMS BOTH PORT AND STARBOARD ENDS.
6. FUNGUS & MOLD: DECK BEAMS(S) IWO DECK BEAMS AND DECK BOARDS PORT SIDE FWD. HOLD, STARBOARD SIDE MAIN HOLD IWO SHEER CLAMP AND SHELF. ENGINE SPACE OVERHEAD IWO DECK BEAMS AND DECK PLANKING.
7.DECK PLANK ROT IWO ENGINE SPACE OVERHEAD PORT & STBD S
8. FIRRING & ANGEL HAIR AROUND BASE OF MAST STEP AND MAST PLATE BOLTS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2021
Resolved 22 March 2023
Resolution: Partial completion. Re-issued in activity 7654657
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 November 2020
Resolved
A satisfactory U/W check ride is req for credit Dry-dock
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2020
Resolution: Completed Underway Sea Trial.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 27 March 2019
Resolved
Any vessell of at least five net tons which engages in the fisheries on the navigable waters of the United States must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel was unable to provide the Certificate of Documentation for review. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Resolution: Vessel O/O presented valid originial copies of the Certificate of Documentation and Certificate of Inspection.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 March 2019
Resolved
Electrical Equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards, including fire caused by or originating in electrical equipment and electrical shock. Remove/repair exposed wires from the electric bilge pump in the Engine Room 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Resolution: Verified that exposed wires attached to old bilge float switch in E/R removed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 27 March 2019
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level in the vessel. The High Water alarm is inoperable. Repair or replace high water alarm on vessel. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2019
Resolution: Verified proper operation of vesel Bilge High Water Alarm in E/R.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 27 March 2019
Resolved
Repairs or alterations to include repairs or refastening of decks must not be made without approval of the cognizant OCMI. Provide a repair proposal for the restoration of the areas identified by the attending Marine Inspector IWO the STDB side Operating Station paneling and deck boards and the area IWO the Port Side railing and post. 46 CFR 176.700(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2019
Resolved 17 April 2019
Resolution: Verified proper repairs made to the stdb side deck boards, operating station panels and port side deck rails.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 18 April 2018
Resolved
Captain's license expired, Renew and provide to attending marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2018
Resolved 22 June 2018
Resolution: Received email picture showing above deficiency has been corrected.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 April 2018
Resolved
Provide proof of enrollment in drug consortiu for entire crew.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2018
Resolved 22 June 2018
Resolution: Received email picture showing above deficiency has been corrected.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 April 2018
Resolved
Provide 02 alcohol test kits on board.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2018
Resolved 22 June 2018
Resolution: Received email picture showing above deficiency has been corrected.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 April 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2018
Resolved 25 June 2018
Resolution: Received a copy of the new FCC Station License via email.
Lifesaving › Hand Flares › Expired
Issued 18 April 2018
Resolved
Provide 03 Red hand flares.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2018
Resolved 22 June 2018
Resolution: Received email picture showing above deficiency has been corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2016
Resolved
Remove temporary lighting throughout below deck spaces. Repair/replace permanent lighting and prove proper operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 8 July 2016
Resolution: Received pictures via email showing the repairs tothe existing system and removal of the temporary lighting.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 June 2016
Resolved
Provide on board alcohol test kits (2 required).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2016
Resolved 15 June 2016
Resolution: Received email Picture of Alco sensor.