MAURY USCG vessel records
← All vessels

ISLAND GIRL III

Built
2002
Last inspected
23 September 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 September 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDP7071
577935
Flag
UNITED STATES
Maury page id
psix-577935

Documentation record

Registered dimensions (L × B × D)31.0 ft × 12.0 ft × 6.0 ft
Registered tonnagegross 14 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMORGAN BOATS INC · NAPLES, FL, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portBOKEELIA, FL
Endorsements, as the file codes themcw_un, fi, rec
DocumentationValid · issued 20 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

23 September 2025 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8241811
3 June 2025 Annual Inspection · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8147062
26 November 2024 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8040282
4 March 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7871673
13 December 2022 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7607884
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576888
1 March 2022 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7403213
4 March 2021 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7149357
26 October 2020 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7082779
25 October 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6839372
18 December 2018 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6597861
11 October 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6558201
14 November 2017 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6306749
24 January 2017 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6065273
5 October 2016 Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6012136
19 January 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5791859

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. The pre-engineered fixed gas fire extinguishing system agent bottle is excessively corroded. Replace the pre-engineered fixed gas fire extinguishing system agent bottle in kind. Provide an NFPA authorized third party technician report of installation and alarm testing IAW NFPA 10. 46CFR181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2025
Resolution: Replaced the pre-engineered fixed gas fire extinguishing system agent bottle in kind. Provided an NFPA authorized third party technician report of installation and alarm testing IAW NFPA 10. Witnessed system shut down and override.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Identified 18 adult sized life jackets in unsatisfactory condition, due to deteriorated flotation material. 02 adult sized life jackets are in satisfactory condition. Replace 16 adult sized life jackets to be in compliance with required lifesaving equipment as specified on the COI. 46CFR180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2025
Resolution: Replaced 16 adult sized life jackets; properly labeled and stowed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 November 2024 Resolved
Vessel is overdue for its hull exams due 31OCT2024 as listed on the COI. Vessel must have a satisfactory hull exam prior to returning to service. 46 CFR 176.600
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 June 2025
Resolution: Completed hull examination and annual inspection on vessel ISLAND GIRL III (ON 1132379), see activity number 8147062.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 25 October 2019 Resolved
Renew expired FCC Safety Certificate
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2019
Resolved 8 November 2019
Resolution: New Safety Radiotelephony Certificate
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 November 2017 Resolved
Light on mid bilge alarm is burnt out, replace bulb.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 11 December 2017
Resolution: Replaced bulb.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 January 2017 Resolved
Re-letter lifejacket stowage labeling, letters are peeling off. (46CFR 180.78(a)(5)
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 31 January 2017
Resolution: new letters for life jacket stowage were placed.
Lifesaving › Lifebuoys › Serviceable
Issued 24 January 2017 Resolved
Re-label life ring lettering due to missing letters. (46CFR 180.70(3)(b)(1)
Action required: 705 - Other - as specified
Due 7 February 2017
Resolved 31 January 2017
Resolution: Life ring lettering was replaced.
Construction/Loadline › Hull › Bottom Plating
Issued 5 October 2016 Resolved
Make permanent repairs damaged hull areas identified
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 4 November 2016
Resolution: repaired all damaged areas of gel coat.
Construction/Loadline › Structures › Deck Plating
Issued 5 October 2016 Resolved
Deck surface creates a potential slip hazard, apply slip prevention coating.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 November 2016
Resolution: Renewed deck non skid.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 5 October 2016 Resolved
Fire extinguisher bracket is corroded and requires replacement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 November 2016
Resolution: Replaced bracket.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 5 October 2016 Resolved
switch panel board at operating station was not covered.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 November 2016
Resolution: covered exposed openings of switch panel at helm.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 19 January 2016 Resolved
Post placard to energize blowers & run to have one complete air change at the operating station, IAW 46 CFR 182.460(e).
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 2 February 2016
Fire Fighting › Fire Bucket › Stenciling
Issued 19 January 2016 Resolved
Label fire buckets in contrasting colors on all buckets, IAW 46 CFR 181.610.
Action required: 705 - Other - as specified
Due 2 February 2016
Resolved 22 January 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.