Records from 2002 to 2008. Most recent: inspection, 5 June 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
5 June 2008
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3228190
2 June 2008
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3213759
4 June 2007
Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2951103
19 May 2006
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2836914
10 March 2006
Administrative Inspection
Administrative · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2600008
1 June 2005
Re-Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2375870
2 June 2004
Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2100267
3 June 2003
Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1815761
4 October 2002
Deficiency Check
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1684385
3 June 2002
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1640516
Communications › Visual Communication › Warning Sign (radio room)
Issued 3 June 2008
Resolved
Post emergency roadcast placard.
Condition: Unknown
Due 3 July 2008
Resolved 2 June 2009
Resolution: Placard was posted.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 June 2008
Resolved
Remove unauthorized life jackets.
Condition: Unknown
Due 3 June 2008
Resolved 3 June 2008
Resolution: Removed
Fire Fighting › Ventilation Systems › Ducts
Issued 2 June 2004
Resolved
Replace screen on stern with approved flamescreen.
Condition: Improper Installation
Due 2 August 2004
Resolved 6 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 June 2004
Resolved
Replace stern light.
Condition: Unknown
Due 2 August 2004
Resolved 6 June 2005
Electrical › Electrical Distribution System (service)
Issued 17 July 2002
Resolved
Properly label fuse panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Fuse panel labelled properly by vessel''s crew.
Electrical › Electric Supply System (service)
Issued 17 July 2002
Resolved
Submit single line electrical drawing (conductor size and type, overcurrent protection installed, connected loads). LEGACY COMPONENT DESC: Overcurrent Device
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Received proper drawing from vessel''s manufacturerer.
Electrical › Electric Supply System (service)
Issued 17 July 2002
Resolved
Provide all wire runs at 24 inches with metal supports. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Wire supports installed by vessel''s crew.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 July 2002
Resolved
Install bonding straps on fuel tank. LEGACY COMPONENT DESC: Tank
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Bonding strap installed by vessels crewmembers.
Construction/Loadline › Structures
Issued 17 July 2002
Resolved
Install gate as per approved Coast Guard plans or provide alternative action that must be approved by marine inspector. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Proper gate installed by [name withheld] of Apache Boatbuilders.
Construction/Loadline › Hull
Issued 17 July 2002
Resolved
Repair hull damage on stbd side near bow. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Top coat repaired by local craftsman.
Lifesaving › Hand Flares
Issued 17 July 2002
Resolved
Provide flares onboard vessel when used as an excursion vessel. LEGACY COMPONENT DESC: Quantity
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Flares provided by vessels owners.
Operations/Management › Drills/Instruction
Issued 17 July 2002
Resolved
Provide on board emergency procedures along with navigational rules booklet and charts. LEGACY COMPONENT DESC: Fire
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Written procedures and drill cards prepared and provided by vessel owner.
Fire Fighting › Remote Fuel Shutoff
Issued 17 July 2002
Resolved
Provide fuel shutoff valves on fuel tank as per 46CFR 182.455(b)(4) and 185.608 marking requirements. LEGACY COMPONENT DESC: Fuel tank
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Emergency cutoff valves installed by [name withheld] of Apache Boatbuilders.
Lifesaving › Lifebuoys
Issued 17 July 2002
Resolved
Provide proper size life ring line. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Proper lines provided by vessel owners.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 July 2002
Resolved
Provide plans for alternative compliance for fuel tank compartment regulations as per 46CFR181.400 or comply with said regulations. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Vessel boatbuilders provided natural ventilations ports for fuel tank space.
Navigation › Collision/Grounding Avoidance
Issued 17 July 2002
Resolved
Remove canopy obstruction from stern light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Canopy properly fitted to show stern light properly.
Lifesaving › Embarkation Appliances/Stations
Issued 17 July 2002
Resolved
Provide ladder for water extraction. LEGACY COMPONENT DESC: Steps
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Extraction ladder provided by vessels owner.
Operations/Management › Drug and Alcohol Testing
Issued 17 July 2002
Resolved
Ensure all employees are enrolled in a drug testing program and submit records to MSD Peoria. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Vessel operators enrolled in program with National Park personnel.