MAURY USCG vessel records Sign in
← All vessels

LARKSPUR

LARKSPUR is a 2002 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 2002, most recently in June 2008, along with 18 deficiencies.

Records from 2002 to 2008. Most recent: inspection, 5 June 2008.

Built
2002
Last inspected
5 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

578146
Flag
UNITED STATES
—
Maury page id
psix-578146

Inspections, by type

Years with a record 7 calendar years (2002–2008)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

5 June 2008 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3228190
2 June 2008 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3213759
4 June 2007 Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2951103
19 May 2006 Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2836914
10 March 2006 Administrative Inspection
Administrative · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2600008
1 June 2005 Re-Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2375870
2 June 2004 Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2100267
3 June 2003 Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1815761
4 October 2002 Deficiency Check
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1684385
3 June 2002 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1640516

Deficiency record · 18

Communications › Visual Communication › Warning Sign (radio room)
Issued 3 June 2008 Resolved
Post emergency roadcast placard.
Condition: Unknown
Due 3 July 2008
Resolved 2 June 2009
Resolution: Placard was posted.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 June 2008 Resolved
Remove unauthorized life jackets.
Condition: Unknown
Due 3 June 2008
Resolved 3 June 2008
Resolution: Removed
Fire Fighting › Ventilation Systems › Ducts
Issued 2 June 2004 Resolved
Replace screen on stern with approved flamescreen.
Condition: Improper Installation
Due 2 August 2004
Resolved 6 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 June 2004 Resolved
Replace stern light.
Condition: Unknown
Due 2 August 2004
Resolved 6 June 2005
Electrical › Electrical Distribution System (service)
Issued 17 July 2002 Resolved
Properly label fuse panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Fuse panel labelled properly by vessel''s crew.
Electrical › Electric Supply System (service)
Issued 17 July 2002 Resolved
Submit single line electrical drawing (conductor size and type, overcurrent protection installed, connected loads). LEGACY COMPONENT DESC: Overcurrent Device
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Received proper drawing from vessel''s manufacturerer.
Electrical › Electric Supply System (service)
Issued 17 July 2002 Resolved
Provide all wire runs at 24 inches with metal supports. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Wire supports installed by vessel''s crew.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 July 2002 Resolved
Install bonding straps on fuel tank. LEGACY COMPONENT DESC: Tank
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Bonding strap installed by vessels crewmembers.
Construction/Loadline › Structures
Issued 17 July 2002 Resolved
Install gate as per approved Coast Guard plans or provide alternative action that must be approved by marine inspector. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Proper gate installed by [name withheld] of Apache Boatbuilders.
Construction/Loadline › Hull
Issued 17 July 2002 Resolved
Repair hull damage on stbd side near bow. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Top coat repaired by local craftsman.
Lifesaving › Hand Flares
Issued 17 July 2002 Resolved
Provide flares onboard vessel when used as an excursion vessel. LEGACY COMPONENT DESC: Quantity
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Flares provided by vessels owners.
Operations/Management › Drills/Instruction
Issued 17 July 2002 Resolved
Provide on board emergency procedures along with navigational rules booklet and charts. LEGACY COMPONENT DESC: Fire
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Written procedures and drill cards prepared and provided by vessel owner.
Fire Fighting › Remote Fuel Shutoff
Issued 17 July 2002 Resolved
Provide fuel shutoff valves on fuel tank as per 46CFR 182.455(b)(4) and 185.608 marking requirements. LEGACY COMPONENT DESC: Fuel tank
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Emergency cutoff valves installed by [name withheld] of Apache Boatbuilders.
Lifesaving › Lifebuoys
Issued 17 July 2002 Resolved
Provide proper size life ring line. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Proper lines provided by vessel owners.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 July 2002 Resolved
Provide plans for alternative compliance for fuel tank compartment regulations as per 46CFR181.400 or comply with said regulations. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Vessel boatbuilders provided natural ventilations ports for fuel tank space.
Navigation › Collision/Grounding Avoidance
Issued 17 July 2002 Resolved
Remove canopy obstruction from stern light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Canopy properly fitted to show stern light properly.
Lifesaving › Embarkation Appliances/Stations
Issued 17 July 2002 Resolved
Provide ladder for water extraction. LEGACY COMPONENT DESC: Steps
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Extraction ladder provided by vessels owner.
Operations/Management › Drug and Alcohol Testing
Issued 17 July 2002 Resolved
Ensure all employees are enrolled in a drug testing program and submit records to MSD Peoria. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 September 2002
Resolution: Vessel operators enrolled in program with National Park personnel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.