Professional
The full record for this vessel
Behind this panel: 17 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
30 April 2022
PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7438411
2 December 2021
PSC B · COC-GAS Renew · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7354146
30 January 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7133351
22 November 2020
COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7096716
24 October 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7083399
27 July 2020
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7137331
3 July 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6994391
13 November 2019
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6847400
26 November 2018
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6586092
9 August 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6506607
15 October 2017
Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6286713
21 June 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6182146
11 October 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6019752
5 October 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6016485
4 October 2016
COC-GAS Annual · ISPS III Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6015412
24 May 2016
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5885673
21 April 2016
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5859343
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Compliance (COC)
Issued 6 December 2021
Resolved
No person may operate a vessel unless that person complies with all limitations in the endorsement on the vessel's Certificate of Compliance. Upon finding multiple electrical deficiencies in the cargo area, the vessel failed her COC examination and was expressly instructed not to conduct cargo operations. The deficiencies were issued on a Port State Control Report of Inspection and signed/stamped by the master. After the Coast Guard team departed, the vessel resumed their cargo operations which were prohibited by the attending examination team and acknowledged by the master.
46 CFR 154.1808
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2021
Resolution: Vessel rectified all prior to cargo deficiencies and received their COC prior to completing cargo operations.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo density declaration
Issued 2 December 2021
Resolved
Electrical equipment, cable and wiring should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the Organization. PSCO observed cabling for the cargo compressor junction box on both port and starboard cargo compressors to be loose and packed with silicone within the cable glands. Multiple bonding straps for the port cargo compressor piping were found wasted. Deficiency must be rectified prior to cargo operations and prior to departure.
74 SOLAS (14 Cons.) Ch VII/Reg. 13.1
IGC 93/Reg. 10.5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2021
Resolved 6 December 2021
Resolution: After receiving BV class report. USCG team re-attended to verify repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 December 2021
Resolved
Pressure relief valves should be set and sealed by a competent authority acceptable to the Administration. PSCO noted that the tamper seal for the MARV with serial # M06348-1-PM-01-2 was found missing.
74 SOLAS (14 Cons.) Ch. VII/Reg. 13.1
IGC 93/Reg. 8.25
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 December 2021
Resolved 6 December 2021
Resolution: After receiving BV class report. USCG team re-attended to verify repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 December 2021
Resolved
Each cargo pump discharge line and each liquid and vapour cargo manifold should be provided with at least one pressure gauge. Pressure gauge for the cargo-stbd condenser on the #1 tank top was found broken. Crew was able to replace.
74 SOLAS (14. Cons) Ch. VII/Reg. 13.1
IGC 93/Reg. 13.4.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 December 2021
Resolved 2 December 2021
Resolution: Crew used spare guages to replace broken pressure gauges.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2021
Resolved
Electrical equipment, cable and wiring should not be installed in hazardous locations unless it conforms with the standards. PSCO noted a loose cable gland on ESD junction box #4 and a hole in junction box on tank top #2.
74 SOLAS (14 Cons.) Ch. VII/Reg. 13.1
IGC 93/Reg. 10.5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 6 December 2021
Resolution: After receiving BV class report. USCG team re-attended to verify repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 December 2021
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. Mounts to pressure gauges to cargo cooling saltwater pump, ballast pump, and ballast/fire general service pump were missing or broken leaving gauges unsecured.
74 SOLAS (01 Cons.) Ch. II-1/Reg. 26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 December 2021
Resolved 6 December 2021
Resolution: After receiving BV class report. USCG team re-attended to verify repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 December 2021
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. PSCO observed emergency light fixture above the starboard cargo compressor space to be missing structural guard, leaving glass housing and fixture exposed to potential damage.
74 SOLAS (01 Cons.) Ch. II-1/Reg. 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 6 December 2021
Resolution: After receiving BV class report. USCG team re-attended to verify repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 2 December 2021
Resolved
The condition of the ship and its equipment should be maintained to conform with the provisions of the Code to ensure that the ship will remain fit to proceed to sea without danger to the ship or person onboard. PSCO observed severe deterioration and corrosion of the internal motor components of the cargo compressor motors.
74 SOLAS (14. Cons.) Ch. VII/Reg. 13.1
IGC 93/Reg. 1.5.3.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 January 2022
Resolved 16 December 2021
Resolution: Received class report from BV that stated the motor was fully cleaned and rebuilt to class standard
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 December 2021
Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. PSCO observed that a section of the sewage system piping in the engine room has been replaced with flexible hose as a temporary repair which has not been approved by the Administration.
74 SOLAS (01 Cons.) Ch. I/Reg. 11
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 December 2021
Resolved 16 December 2021
Resolution: Received class report from BV stating that sewage system was satisfactorily tested after re-fit of steel piping.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 November 2018
Resolved
Liferaft containers shall be marked with the items listed in LSA Code 4.2.6.3. The starboard side liferaft was not marked with these items. Liferaft serial number: 11865061
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2018
Resolved 16 December 2018
Resolution: Received date stamped image of new label for liferaft as well as copy of liferaft certificate that matched.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 22 April 2016
Resolved
The gas detection equipment should be capable of sampling and abalysing for each sampling head location sequentially at intervals not exceeding 30 minutes. Vessel's #2 monitoring display unit of the Fixed Gaas Detection System is non-functional due to defective PCB/EPROM. IGCC 13.6.8 40a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2016
Resolved 24 May 2016
Resolution: Received class report attesting to the successful repair, testing and operation of fixed gas detection system.