Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named ANGLER V
ANGLER V is a 2000 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 2000, most recently in May 2025, along with 83 deficiencies — 2 with no resolution recorded — and 1 operational control.
Records from 2000 to 2025. Most recent: inspection, 5 May 2025.
- Built
- 2000
- Last inspected
- 5 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 83 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1095689
WDJ5733
5790
Flag
UNITED STATES
367790740
Maury page id
psix-5790
Inspections, by type
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 16.5 ft × 3.5 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHESAPEAKE BOATS INC · CRISFIELD, MD, UNITED STATES · built 2000
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Net Ton
17 - Simplified, Gross Ton
17 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ5733MMSI 367790740 · active · compulsorily equipped · granted 24 May 2017, expires 24 May 2027
WDA4635MMSI 366811550 · expired · compulsorily equipped · granted 16 May 2001, cancelled 16 July 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 36
5 May 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8129161
13 May 2024
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7911797
2 May 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7903782
11 July 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7739410
4 May 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7681587
6 April 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7663667
21 June 2022
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7482587
6 August 2021
Construction Oversight · Plan Review "T" Boat
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7292141
22 June 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7232426
18 May 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7199851
5 August 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7024456
6 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705873
29 April 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6672392
16 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392229
15 June 2017
Deficiency Check · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6176359
11 January 2016
DAPI Audit · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5813771
29 October 2015
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5757095
26 June 2012
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4358447
11 January 2012
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4222746
11 January 2012
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4223847
5 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4145911
9 February 2011
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3945165
18 March 2009
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3438250
11 June 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3235802
20 March 2008
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3168048
28 June 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2977432
13 April 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2626270
20 March 2006
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2613686
14 April 2005
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2310855
21 April 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2113747
30 March 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2033153
15 April 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1773437
17 April 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1604770
26 March 2002
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1495112
10 April 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1379391
20 April 2000
Inclining Experiment · Hull Examination · Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1457779
Deficiency record · 83
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 August 2025
No resolution recorded
"A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years." Vessel lapsed its required drydock examination date. Complete a credit drydock examination.
46 CFR 176.600(c)(1)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 13 May 2024
No resolution recorded
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Vessel operates primarily in the Long Island Sound (LIS) E.P.A. No Discharge Zone. Vessel does not have an installed Holding Tank (USCG Approved Type III MSD). As such, vessel operator is to prohibit passenger access to the installed toilet while operating in a NDZ.
33 CFR 159.7
705-c / PROHIBIT PAX ACCESS
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 13 May 2024
Resolved
Vessel operator is to establish and provide Sector NY OCMI office with copy of written vessel procedures for addressing passenger sanitation & sewage management while operating within LIS & NY NDZs.
46 CFR 176.800
46 CFR 176.818
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 May 2024
Resolved
TEMPORARY ANCHOR LIGHT REQUIRES PERMANENT REPLACEMENT PER NAVIGATION RULES (COLREGS)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 May 2024
Resolved
ENGINE ROOM WIRE TRANSITS PENETRATING BULKHEADS REQUIRE WATER / VAPOR PROOF SEALING.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 May 2024
Resolved
PATHMAKER 12/24V ELECRICAL BAR / SWITCH SHOWS TERMINAL / WIRE CORROSION FROM WATER INTRUSION. REPAIR / REPLACE TO DRIP / SPLASH PROOF CONDITION. (IN BATTERY COMPT UNDER CABIN)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 2 May 2024
Resolved
TOILET / MSD ELECTROSCAN SYSTEM REQUIRES USCG APPROVAL AND VALVE TO BE LOCKED OR INOPERABLE IN CLOSED POSITION.
ISSUED USCG APPROVAL VERIFICATION AS PRIOR TO CREDIT DDX
VALVE WAS CORRECTED ON THE SPOT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 May 2024
Resolved
PORT MAIN ENGINE L/O PRESS GAUGE INOP. REPAIR / REPLACE.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2024
Resolved
LIFE-FLOAT RETROREFLECTIVE TAPE [WORN / DEGRADED]. REPLACE BOTH SIDES.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 May 2024
Resolved
POST SIGNAGE - NO OVERNIGHT PASSENGER ACCOMODATIONS / PASSENGERS NOT PERMITTED ACCESS TO OVERNIGHT ACCOMODATIONS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2020
Resolved
Remote fuel shutoff station shall be marked in at least one inch letters indicating purpose of valve and direction of operation. Valves not labeled, label fuel shut-off valves.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 August 2020
Resolved
The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifelines and pendants must meet the requirements in Subpart 160.010 of this chapter. Replace lifelines/pendants on all life floats.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 August 2020
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Light not working as approved, replace battery.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 August 2020
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color. Container not of bright color, replace container.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 August 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041. Replace first-aid kit with approved type.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2019
Resolved
ALL ELECTRICAL CONNECTIONS SHALL BE MADE IN JUNCTION BOXES. THERE WERE MULTIPLE CONNECTIONS IN THE LAZARETTE, ENGINE ROOM, TANK SPACE, AND FOR THE LED LIGHTS ON DECK THAT WERE NOT MADE IN JUNCTION BOXES.
46CFR183.340(g)
20JUN2019: DUE DATE EXTENDED DUE TO WEATHER CONDITIONS.
27JUN2019:DEFS EXTENDED DUE TO INCORRECT PARTS SHIPPED.
02JUL2019: CHANGED TO PTCP.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2019
Resolved
FIRST AID KITS SHALL MEET 46CFR160.041 OR CONTAIN EQUIVALENT CONTENTS. THE FIRST AID KIT ON BOARD WAS NOT IN COMPLIANCE OR EQUIVALENT.
46CFR184.710
20JUN2019: DUE DATE EXTENDED DUE TO WEATHER CONDITIONS.
27JUN2019:DEFS EXTENDED.
02JUL2019: CHANGED TO PTCP.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 June 2019
Resolved
EACH LIFESAVING APPLINCE SHALL BEMARKED WITH TYPE IIRETROREFLECTIVE MATERIAL. THE LIFE FLOATS HAD DETERIORATED RETROREFLECTIVE MATERIAL AND THE RING LIFE BUOUY WAS HAD RETROREFLECTIVE MATERIAL THAT WAS NOT IN ACCORDANCE WITH REQUIREMENTS.
46CFR185.604(i)
20JUN2019: DUE DATE EXTENDED DUE TO WEATHER CONDITIONS.
27JUN2019:DEFS EXTENDED.
02JUL2019: CHANGED TO PTCP.
Navigation › Piloting/Steering › Marine Charts
Issued 16 April 2018
Resolved
Provide updated marine charts.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 April 2018
Resolved
Provide 2018 Light List, Coast Pilot, Tide/Current tables and Navigation Rules.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 April 2018
Resolved
Provide eyewash, pain relievers, and burn cream.
Lifesaving › Lifefloat › Paddle
Issued 16 April 2018
Resolved
Provide one additional paddle per life float.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 June 2017
Resolved
Vessel is missing required charts for required route, must have charts for intended route.
Fire Fighting › Fire Bucket › Capacity
Issued 15 June 2017
Resolved
Vessel is required to have 3- 2 1/2 gal fire buckets onboard.
Lifesaving › Hand Flares › Quantity
Issued 15 June 2017
Resolved
Vessel is required to have 6 hand held red flares & 6 orange flares.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 June 2012
Resolved
46 CFR 183.420 All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Anchor light inoperable. Repair anchor light as required.
Lifesaving › Lifefloat › Paddle
Issued 26 June 2012
Resolved
46 CFR 185.604 (g) The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Life float paddles not marked with vessel name. Mark as required.
Lifesaving › Lifefloat › Retroreflective Material
Issued 26 June 2012
Resolved
46 CFR 160.010-4 (p) Each life float must be marked with Type II retroreflective material. Retroreflective tape on lifefloats are wasted. Replace with SOLAS approved tape.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 June 2012
Resolved
46 CFR 180.175(f)(4)The lifefloat floating water light must be attached around the body of the lifefloat by a 3/8 inch lanyard, resistant to deterioration from ultraviolet light, and at least 18 feet in length. Lifefloat light lanyard is waited and is about 6 feet in length. Replace line with one of required length.
Lifesaving › Lifefloat › Markings
Issued 26 June 2012
Resolved
46 CFR 185.604 (a) The name of the vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. Name of vessel wasted on life float. Replace lettering with new.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 26 June 2012
Resolved
46 CFR 185.604 (i) Each life ring buoy must be marked with Type II retroreflective material approved IAW 46 CFR 164.018. Life ring retroreflective material missing. Install correct type.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 26 June 2012
Resolved
46 CFR 182.450 (e) The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. Fuel vent screen missing. Replace or repair to original condition.
Engineering › Fuel Oil Service System › Hose
Issued 26 June 2012
Resolved
46 CFR 182.445 (g) When a nonconductor flexible hose is used between the fuel fill and fuel tank, the nonconductor separation must be joined by a conductor for protection against generation of a static charge. Fuel fill hose not electrically joined to the fuel tank. Join as required.
Engineering › Fuel Oil Service System › Tank
Issued 26 June 2012
Resolved
46 CFR 182.440 (b)(4) All fuel tanks must be electrically bonded to a common ground. Fuel tank not electrically bonded. Electrically bond as required.
Construction/Loadline › Structures › Scuttle
Issued 26 June 2012
Resolved
46 CFR 179.360 (b) A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch covers for fuel tank access not tethered to vessel to prevent loss. Attach to vessel as required.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 June 2012
Resolved
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving provisions for a seaworthy hull. Unused overboard discharge line not capped and would allow for free communication with the sea. Install cap to overboard discharge or attach to system.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 June 2012
Resolved
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving provisions for a seaworthy hull. Unused sea valve in engine room not capped allowing for flooding hazard. Install cap to valve or connect to system.
Construction/Loadline › Penetrations › Gasket
Issued 26 June 2012
Resolved
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving provisions for a seaworthy hull. Starboard engine propulsion shaft seal leaking excessively (1 drop every 2 seconds). Repair packing to reduce leaking.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 June 2012
Resolved
46 CFR 182.530 A visual and audible bilge high level alarm must be provided at the operating station to indicate a high water level. High water bilge alarm for engine space not working. Repair alarm to operating condition.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 June 2012
Resolved
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving provisions for a seaworthy hull. Toilet water inlet hose wasted. Replace with new.
Engineering › Bilge Water Management System › Pump
Issued 26 June 2012
Resolved
46 CFR 182.520 (e)(1) A submersible electric bilge pump must meet the requirements in UL 1113. 12 volt bilge pump inoperative. Replace with approved type.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 June 2012
Resolved
46 CFR 4.06-3 (a)(2) Alcohol testing devices must be used according to the procedures specified by the manufacturer of the testing device. Alcohol test kits missing. Provide as required.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 June 2012
Resolved
46 CFR 16.401 (a) The employer shall provide EAP information displayed on vessel with community service hot-line telephone number. EAP hotline number not provided. Display EAP hotline information as required.
Construction/Loadline › Hull › Sheerstrake
Issued 11 January 2012
Resolved
Vessel has damage on the starboard side washboard (sheer line) in the vicinity of the outside steering station/console, provide a repair proposal prior to any repairs been done.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 March 2009
Resolved
Show proof of enrollment with a DOT approved drug consortium.
Lifesaving › Hand Flares › Expired
Issued 18 March 2009
Resolved
Procure and place in service new, CG approved VDS.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 18 March 2009
Resolved
Provide annual service to portable extinguishers.
Communications › Alarms/Indicators › High Water Alarm
Issued 18 March 2009
Resolved
Procure and place in service new high water alarm in E/R.
Engineering › Steering Gear System › Ram
Issued 20 March 2008
Resolved
Provide rudder stop on steering system to prevent damage to exhaust piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 20 March 2008
Resolved
Provide repairs to 6" dia. hole in starboard exhaust pipe
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 14 April 2005
Resolved
Prior to carrying passengers at night, renew waterlight for life float.
Lifesaving › Lifebuoys › Serviceable
Issued 14 April 2005
Resolved
Prior to carrying passengers, renew life ring and waterlight.
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 14 April 2005
Resolved
Provide current FCC Radio Safety Certificate.
Communications › Radio Communications › VHF Radiotelephone
Issued 14 April 2005
Resolved
Provide current Marine Radio Operators permit.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 April 2005
Resolved
Post Certificate of Inspection, vessel's Stability Letter, FCC Station License, and FCC Radio Safety Certificate in a place that it is visible to passengers.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 April 2005
Resolved
Provide current U.S. Coast Pilot.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 14 April 2005
Resolved
Prior to carrying passengers, provide one B1 fire extinguisher.
Stability › Unintentional Flooding › General
Issued 14 April 2005
Resolved
Provide a means to make the engine hatches watertight.
Engineering › Fuel Oil Service System › Valve, Control
Issued 14 April 2005
Resolved
Provide label for the location of the emergency fuel shut offs.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 April 2005
Resolved
Prior to carrying passenger, provide proof of enrollment in current drug testing program.
Operations/Management › Other Criminal/Civil Violations › Negligent Operations
Issued 14 April 2005
Resolved
Prior to carrying passengers, all outstanding deficiencies must be completed and witnessed by a qualified marine inspector.
Lifesaving › Lifebuoys › Serviceable
Issued 21 April 2004
Resolved
Prior to carrying passengers, replace the ringbuoy and waterlight.
Communications › Alarms/Indicators › Bilge Alarm
Issued 21 April 2004
Resolved
Prior to carrying passengers, renew main cabin high water alarm.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 April 2004
Resolved
Prior to carrying passengers at night, renew waterlights for both life floats.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 21 April 2004
Resolved
Provide updated/ usable copies of Rules of the Road and Coast Pilot.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 15 April 2003
Resolved
RE-INSTALL AND PROVIDE PROOF OF ANNUAL MAINTENANCE FOR ENGINE COMPARTMENT FIXED FIRE FIGHTING SYSTEM PRIOR TO CARRYING PASSENGERS.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 15 April 2003
Resolved
MOUNT BI PORTABLE FIRE EXTINGUISHER AT OPERATING STATION ON UPPER DECK.
Documentation › Certificates/Documents
Issued 15 April 2003
Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Documentation › Manuals/Policy Documentation
Issued 15 April 2003
Resolved
PROVIDE CURRENT COPY OF COAST PILOT.
Personnel › Training
Issued 15 April 2003
Resolved
RENEW RED CROSS FIRST AID/CPR CERTIFICATION. LEGACY COMPONENT DESC: First Aid/CPR
Communications › Radio Communications › VHF Radiotelephone
Issued 17 April 2002
Resolved
Prove operation of VHF Radio.
Engineering › Bilge Water Management System › Valve
Issued 17 April 2002
Resolved
Cap unused thru-hull in battery compartment.
Documentation › Markings/Placards
Issued 17 April 2002
Resolved
Relable Emergency Fuel Shut Off, Label Emergency Flares location and Bilge/High water alarms. LEGACY COMPONENT DESC: Lables
Lifesaving › Buoyant Apparatus
Issued 17 April 2002
Resolved
REPAIR WATERLIGHTS TO LIFE FLOAT PRIOR TO CARRYING PASSENGERS AT NIGHT. LEGACY COMPONENT DESC: WATERLIGHTS
Lifesaving › Lifebuoys
Issued 17 April 2002
Resolved
PROVIDE REFLECTIVE TAPE ON BOTH SIDES OF THE RING BUOY. LEGACY COMPONENT DESC: REFLECTIVE TAPE
Lifesaving › Buoyant Apparatus
Issued 17 April 2002
Resolved
PROVIDE TWO PADDLES FOR EACH LIFE FLOAT LEGACY COMPONENT DESC: PADDLES
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 April 2002
Resolved
PROVIDE PROOF OF FIXED FIRE FIGHTING AUTO SHUT DOWN OPERATION. LEGACY COMPONENT DESC: AUTO SHUT DOWN
Construction/Loadline › Structures
Issued 17 April 2002
Resolved
PROVIDE RETAINING LANYARD FOR DECK HATCHES. LEGACY COMPONENT DESC: Manhole
Lifesaving
Issued 10 April 2001
Resolved
LABEL UPPER DECK FOR MAX PASSENGER CAPACITY AS PER STABILITY LETTER._x001C_ _x001C_ _x001C_
Documentation
Issued 10 April 2001
Resolved
PROVIDE PROOF OF CURRENT RADIO SAFETY CERTIFICATE, FCC STATIONS LICENSE, & MARINE OPERATORS PERMIT.
Engineering
Issued 10 April 2001
Resolved
OPERATE VESSEL ONLY FROM PRIMARY OPERATING STATION UNTIL OPERATIONAL CONSOLE ON 2ND DECK IS FULLY FUNCTIONAL.
Documentation
Issued 10 April 2001
Resolved
PROVIDE PROOF THAT DECK HAND IS ENROLED IN DRUG TESTING PROGRAM.
Lifesaving
Issued 10 April 2001
Resolved
LABEL LOCATION OF 1ST AID KIT.