FISHMONSTER MAX

FISHMONSTER MAX is a 2001 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2003, most recently in June 2026, along with 161 deficiencies, 1 operational control and 1 casualty investigation in 2012.

Records from 2003 to 2026. Most recent: inspection, 8 June 2026.

Built
2001
Last inspected
8 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB3984
579673
Flag
UNITED STATES
368295730
Maury page id
psix-579673

Inspections, by type

…with no type recorded3
Years with a record 21 calendar years (2003–2026)
The 35 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)63.3 ft × 23.7 ft × 7.8 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOOPER MARINE CORP · ST PETERSBURG BEACH, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationTwin Hull
Hailing portKEY WEST, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 8 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Gross Ton
30 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN6078MMSI 368295730 · active · compulsorily equipped · granted 8 February 2023, expires 8 February 2033
WDI5898MMSI 367713140 · expired · compulsorily equipped · granted 2 February 2016, cancelled 4 April 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 35

8 June 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8395900
25 March 2026 Internal Structural Exam · Deficiency Check · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8314244
19 March 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8108014
13 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7911160
19 March 2024 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7879528
13 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7648934
11 October 2022 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7597771
17 March 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7413806
29 September 2020 Examination of Repairs · Drydock Exam · Internal Structural Exam · Damage Survey · Deficiency Check · Simplified Stability Test
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7067684
21 October 2019 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6838547
28 January 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6589020
31 October 2018 Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6571685
6 December 2017 Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6319170
8 November 2016 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6056667
25 October 2016 Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6029949
11 October 2016 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6016448
12 January 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5797643
28 October 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5000531
20 January 2012 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4230537
15 December 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4211116
7 December 2010 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3905845
29 October 2010 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3880481
8 October 2010 Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 3867186
4 January 2010 Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3658125
4 December 2009 Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3644681
5 February 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3412757
28 October 2008 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3353027
1 February 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3141373
16 January 2007 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2856332
27 October 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2811617
7 December 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2542618
13 October 2005 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2513601
25 August 2004 Deadweight Survey · Deficiency Check · Construction Oversight · Hull Examination · Initial Certification
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2242657
19 February 2004 Construction Oversight · Plan Review "T" Boat
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2016155
12 March 2003 Hull Examination · Construction Oversight · Inclining Experiment
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1753630

Deficiency record · 161

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 June 2026 Resolved
Provide an orange or white ring life buoy of at least 24" in diameter with type II retroreflective tape and the vessel's name in capital block letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2026
Resolved 22 June 2026
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 March 2026 Resolved
Refasten the inboard aft deck beam shelf in the starboard engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2026 Resolved
Seal the gap in the starboard engine room's aft bulkhead to make the space vapor tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 March 2026 Resolved
Seal the drain holes on the bottom of the port and starboard collision bulkheads.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 March 2026 Resolved
Attach the starboard #3 hatch cover to the hatch frame with a captive chain/cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 March 2026 Resolved
Insulate the exposed sections of hot piping on the port and starboard exhaust risers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 March 2025 Resolved
Provide a visual alarm to indicate a high water level in the starboard lazarette (audible is working).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 8 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must be designed with enough capacity for the volume of space it is protecting. Reinstall the original board or provide another means to establish a vapor boundary in non-watertight bulkhead between the port engine room and tank space prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2024 Resolved
Provide an all-round white light to be illuminated when the vessel is at anchor or aground in periods of reduced visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2024 Resolved
Mark the stairs or entry to the upper deck with the maximum number of passengers permitted on the upper deck (Maximum 12 passengers on the upper deck). Marking must be at least 1" numbers and letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2024 Resolved
Conduct and log abandon ship, man overboard, and fire fighting drills every three months. Log must contain the date of the drill, a general description, and the individuals in attendance.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 March 2024 Resolved
There is water ingress around the port tank space hatch. Surrounding wood is waterlogged but not rotted. Dry area and rebed hatch prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 13 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023 Resolved
Life floats are strapped to the top of the house with mooring lines and cleats. Stow all life floats so they can float free prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 15 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023 Resolved
Provide two paddles of at least 4 feet in each life float and lash each paddle to the life float to witch it belongs prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 15 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 March 2023 Resolved
Clearly mark the name of the vessel on each life float and each life float paddle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2023 Resolved
Provide one portable hand pump with suitable hose and suction to pump bilge water overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2022 Resolved
Provide MSC approved Design Verification Test Procedures to show that a loss of power to the electronic propulsion control system does not result in increased shaft speed or propeller pitch. Must be provided prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2022 Resolved
Perform the MSC approved Design Verification Test Procedures without an increase in shaft speed or propeller pitch prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 September 2020 Resolved
VESSEL SUSTAINED EXTENSIVE DAMAGE TO THE UNDERSIDE OF THE HULL CONNECTING TWO CATAMARAN HULLS TOGETHER IN WAY OF THE MIDSHIP SECTION ON THE PORT SIDE OF THE CENTERLINE. DETERMINE EXTENT OF DAMGE BY REMOVAL OF COMPROMISED FIBERGLASS AND ANY OTHER DAMAGED STRUCTURAL COMPONENTS OF VESSEL. SUBMIT REPAIR PROPOSAL TO OCMI TO RENEW AS ORIGINALLY INSTALLED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTURE.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2020
Resolved 31 January 2022
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 9 December 2019 Resolved
When CG Marine Inspectors conducted a Chemical Testing Program Compliance Audit, it was discovered that the current, credentialed Master onboard the vessel never submitted a pre-employment chemical test prior to hire, and the Owner had no documentation onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 December 2019
Resolved 10 December 2019
Resolution: Refer to Enforcement with a Letter of Warning
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 December 2019 Resolved
Seal all penetrations in the bulkheads from the engine rooms to ensure the proper operation of the FIREBOY system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019 Resolved
All wires and cables in the engine room compartment must be supported every 18 inches with metal brackets lined with a rubber material to prevent chafing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2019 Resolved
Submit plan/specs for install of new generator. After install conduct test of associated fireboy system in the presence of Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 9 December 2019 Resolved
eplace all floating water light batteries with batteries approved for use in waterlights and mark with expiration date (maximum 2 years from date of install)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019 Resolved
Remove or properly cap off all dead end wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019 Resolved
Block off unused openings in the distribution panel at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2019 Resolved
Replace rub rail on port bow to assist in preventing damage tot he hull from impacting the pilling.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2019 Resolved
Label bilge alarms for the aft fuel space as "not high water alarms".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 9 December 2019 Resolved
Provide first aid kit with required contents. 160.041
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 December 2019 Resolved
Repair electrical cable to aft anchor light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 October 2019 Resolved
Vessel must have up to date publications on board. Coast Pilot is outdated from 2012.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 January 2019 Resolved
A Pre-engineered Fixed gas fire extinguishing system must automatically shutdown all engines that draw intake within the protected space. Fireboy electrical pigtail was broken and will not shutdown engine upon activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2019
Resolution: New cylinder installed and operationally tested.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 28 January 2019 Resolved
Demonstrate proper Audible and visual operation of bilge high level alarms in Port/STBD Engine rooms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2019
Resolution: All high level alarms operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2019 Resolved
Demonstrate proper operation of fuel shutoff valve on STBD tank for Engine supply line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2019
Resolution: Fuel shutoff operates properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
Connect bilge pump conductor wire with a pressure type connector in Port forward compartment. Current connection made with twisting wire and electrical tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Pressure type connector installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 January 2019 Resolved
Repair/replace 22 person Life-floats. Both Life-Floats have sun damage and are no longer international orange.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: Life float painted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
Provide cover for 110 power receptacle under bar.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Cover provided for receptacle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 January 2019 Resolved
Provide gaskets for Port and STBD engine room deck hatches. Repair STBD lazarete hatch gasket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Gaskets replaced/repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 January 2019 Resolved
Post all pages of COI (03 pages.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: All pages posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 January 2019 Resolved
Provide current publications (Coast Pilot [name withheld])
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: All publications onboard are up to date.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
AC/DC panel has missing slots, cover to protect against risk of shock.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Missing slots covered on DC/AC panel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 January 2019 Resolved
Demonstrate proper operation of visual indicators for automatic bilge pumps (Port forward compartment, Port E/R, STBD aft fuel).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: All visual indicators are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 January 2019 Resolved
Replace watertight container for distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Watertight container provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
Provide a fuse in series (over current protection) for 02 house batteries. Battery cables are an estimated 10 feet from panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2019
Resolution: Over current protection installed at battery terminal (100 amp)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019 Resolved
Provide means to protect battery terminals from failing objects (Cover or boots).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Battery terminals covered with box cover.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 January 2019 Resolved
Vessel captains did not have a medical certificate. Provide medical certificate to local OCMI and keep with credential.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2019
Resolution: Medical certificate valid for acting captain.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 January 2019 Resolved
Vessel captains did not have a FCC radio operator license. Provide FCC radio operator license to local OCMI and keep with credential.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: FCC operator permit provided for acting captain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019 Resolved
Replace hydraulic lines and fittings to reduction gear. Fittings are wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: Hydraulic lines replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019 Resolved
Replace lagging on turbo starboard engine. Lagging deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Lagging replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2019 Resolved
[name withheld] stowage locations on main deck with type and number. Old markings were painted over and illegible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: All PFD stowage locations marked.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 January 2019 Resolved
Vessel must be equipped with a VHF-DSC radio. Vessel radio was not providing lat and long.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: GPS input for VHGF radio operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 November 2018 Resolved
Conduct/complete hull examination (drydock), drydock due date listed on current COI is October 31st, 2018. Last credit drydock was completed on October 28th, 2016.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2018
Resolution: Vessel completed credit drydock, updated vessel profile.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018 Resolved
ENSURE THAT BOTH CUTLASS BEARINGS ARE REPLACED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: Cutlass bearings replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 November 2018 Resolved
SEVERAL COMPONENTS ARE NOT PROPERLY GROUNDED INCLUDING BOTH FUEL TANKS. ENSURE NON METALIC FUEL FILL/VENT LINES ARE BRIDGED WITH A BONDING STRAP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2018
Resolution: Fuel tank fills bonded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2018 Resolved
THE BRIDGE ELECTRICAL PANEL IS SECURED WITH PARACHUTE CORD AND A FISHING HOOK. ENSURE THAT THE PANEL IS PROPERLY SECURED VIA MECHANICAL MEANS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: Lock provided to prevent access to electrical panel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 November 2018 Resolved
ENSURE ALL OVERBOARD DISCHARGE VALVES ARE PROPERLY FUNCTIONING. THE FORWARD STARBOARD BILGE VALVE AS WELL AS SEVERAL ON THE PORT SIDE HAVE SEIZED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: All vales functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018 Resolved
THE FITTINGS ON THE FUEL LINES RUNNING OUT OF THE STARBOARD TANK HAVE SEVERE CORROSION. ENSURE FITTINGS ARE REPLACED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: Fuel lines replaced.
Engineering › Bilge Water Management System › Pump
Issued 14 June 2018 Resolved
Permanently mount all submersible electric bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2018
Resolution: Bilge pumps mounted to hull.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 June 2018 Resolved
Mount high level alarm in STBD laz compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2018
Resolution: High level indicator mounted in Laz compartment.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 December 2017 Resolved
Prove operation of starboard Fireboy alarms and shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2017
Resolution: Demonstrated proper operation of system.
Communications › Radio Communications › EPIRB
Issued 6 December 2017 Resolved
Replace expired EPIRB battery.
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 26 December 2017
Resolution: Replaced battery.
Lifesaving › Lifefloat › Serviceable
Issued 6 December 2017 Resolved
Make repairs to starboard lifefloat in accordance with manufacturer's instructions.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 26 February 2018
Resolution: Replaced lifefloat with new.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 December 2017 Resolved
Replace batteries in starboard lifefloat light and lifering light.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Replaced batteries.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 December 2017 Resolved
Replace/update navigational charts and pubs.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 26 December 2017
Resolution: Replaced charts and publications.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 December 2017 Resolved
Input GPS to the VHF radio
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 8 December 2017
Resolution: Connected vessel's GPS to VHF radio
Communications › Alarms/Indicators › High Water Alarm
Issued 6 December 2017 Resolved
Demonstrate proper operation of port fuel tank compartment high level alarm and automatic bilge pump indicator.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Demonstrated proper operation of high level alarm and automatic pump indicator.
Engineering › Bilge Water Management System › Pump
Issued 6 December 2017 Resolved
Demonstrate proper operation of installed bilge system.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 14 June 2018
Resolution: Fixed bilge system removed, all spaces have submersible pumps.
Electrical › Electrical Distribution System (service) › Cable
Issued 6 December 2017 Resolved
Remove flexible cord from distribution panel to fire pump. Renew with approved cable.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 14 June 2018
Resolution: Fire pump removed, not required on board.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 December 2017 Resolved
Replace broken exterior electrical outlets on back deck.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Replace outlet and properly mounted.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 December 2017 Resolved
Place port engine batteries in tray.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Placed batteries in battery boxes.
Stability › Watertight Integrity › General
Issued 6 December 2017 Resolved
Make repairs to watertight hatches.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 26 February 2018
Resolution: Watertight hatches repaired.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 December 2017 Resolved
Provide logs of drills and monthly EPIRB tests.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 26 February 2018
Resolution: Provided log.
Fire Fighting › Fire Pumps › Pressure
Issued 6 December 2017 Resolved
Install pressure gauge on discharge side of fire pump.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 14 June 2018
Resolution: Fire pump removed.
Construction/Loadline › Hull › Hull Plating
Issued 25 October 2016 Resolved
Repair hull in way of all Coast Guard marked areas.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Gel coat renewed in way of all marked areas.
Construction/Loadline › Structures › Manhole
Issued 25 October 2016 Resolved
Repair/replace hatch lanyards to below deck spaces.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Hatch lanyards either refitted or replaced.
Construction/Loadline › Hull › Hull Plating
Issued 25 October 2016 Resolved
Repair/replace areas noted by Coast Guard in way of aft ladder to upper deck and bait well.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Floor joint around aft ladder, main deck cleaned of old caulk and glassed over.
Construction/Loadline › Penetrations › Gasket
Issued 25 October 2016 Resolved
Repair/replace gaskets to below deck hatches.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Gaskets to hatches repaired.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2016 Resolved
Coat deck with non skid.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Deck coated with non skid.
Unknown
Issued 25 October 2016 Resolved
Replace zincs.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: All zincs replaced.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 25 October 2016 Resolved
Replace port/starboard cutlass bearings.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Port/starboard cutlass bearings replaced.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 25 October 2016 Resolved
Realign prop shaft.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Prop shafts realigned.
Lifesaving › Lifefloat › Serviceable
Issued 11 October 2016 Resolved
Repair/renew lifefloats. Vessel restricted to operating no more than 3 miles from land.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 1 December 2016
Resolution: Procured/installed new lifefloat
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 October 2016 Resolved
Provide floating waterlight for lifebuoy. Vessel restricted to daytime operations.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 11 October 2016
Resolution: Provided light
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 October 2016 Resolved
Provide lifeline for lifebuoy
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2016
Resolved 11 October 2016
Resolution: Renewed line
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 October 2016 Resolved
Reinstall access cover to port engine room forward bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2016
Resolution: reinstalled and sealed access cut out in bulkhead
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 October 2016 Resolved
Properly secure starboard engine room batteries to satisfaction of attending marine inspector
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 8 November 2016
Resolution: Installed new straps to secure battery
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 October 2016 Resolved
Post COI and Stability letter
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 16 October 2016
Resolution: Posted all pages of COI and Stability Letter.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 October 2016 Resolved
Post PFD donning placards on upper deck
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 8 November 2016
Resolution: Posted donning instructions on second deck
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 October 2016 Resolved
Provide master's credentials
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2016
Resolution: Provided credentials
Communications › Alarms/Indicators › High Water Alarm
Issued 11 October 2016 Resolved
Repair/renew the following: High level alarms for port and stbd forepeak, automatic bilge pump indicators for port and stbd aft fuel tank spaces and port laz
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 1 December 2016
Resolution: Proved proper operation
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 October 2016 Resolved
Demostrate proper operation of engine shutdowns for port and starboard pre-engineered fire extinguishing systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2016
Resolution: Demonstrated proper operation of systems shutting down all engines
Documentation › Certificates/Documents › FCC SSL
Issued 12 January 2016 Resolved
Vessel did not have FCC radio station license that identified it was for the TORTUGA IV
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: New SSL provided
Documentation › Certificates/Documents › Stability Letter
Issued 12 January 2016 Resolved
COI and Stability letter were not posted visible to passengers.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: Items posted
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 January 2016 Resolved
Vessel did not have company drug testing policy on board and available to review.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: program provided.
Engineering › Bilge Water Management System › Not Operational
Issued 12 January 2016 Resolved
Bilge high level water alarm in starboard void was inoperable.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: proved proper operation
Lifesaving › Hand Flares › Quantity
Issued 12 January 2016 Resolved
Vessel had only 8 of required 12 flares
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: Additional flares provided
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 January 2016 Resolved
Life Float light battery was dead. Replace battery.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: battery replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 December 2011 Resolved
KW01 Double clamp hose intake on starboard air conditioning.
Due 16 December 2011
Resolved 15 December 2011
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 December 2011 Resolved
KW02 Acquire 01 DOT approved alcohol test kit. Access to second by passengers is not allowed until acquired. Vessel is limited to 01 master and 01 deckhand.
Due 22 December 2011
Resolved 22 December 2011
Stability › Watertight Integrity › Deadlight Cover
Issued 15 December 2011 Resolved
KW03 Attach deck covers
Due 22 December 2011
Resolved 19 December 2011
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 December 2011 Resolved
KW04 Repair fractures on rescue ladder
Due 22 December 2011
Resolved 22 December 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 7 December 2010 Resolved
Replace batteries in 03 life float lights.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2010
Resolved 7 December 2010
Resolution: Batteries replaced on spot.
Communications › Radio Communications › EPIRB
Issued 7 December 2010 Resolved
Replace EPIRB Battery (Limited to 3NM from shore).
Condition: Improper/Lack of Maintenance
Due 14 December 2010
Resolved 15 December 2010
Resolution: EPIRB completely replaced and installed sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2010 Resolved
Install missing bolts on handrails.
Condition: Improper/Lack of Maintenance
Due 7 December 2010
Resolved 8 December 2010
Resolution: Bolts on handrail installed.
Communications › Visual Communication › Warning Sign (gangway)
Issued 7 December 2010 Resolved
Install placard for ladder informing passengers that ladder is for emergency use only.
Due 7 December 2010
Resolved 8 December 2010
Resolution: Placard put in place on forward ladder.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 December 2010 Resolved
Replace retroreflective tape on 02 PFDs.
Condition: Improper/Lack of Maintenance
Due 14 December 2010
Resolved 8 December 2010
Resolution: New retroreflective material put on PFDs.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 December 2010 Resolved
Acquire updated Coast Pilot.
Condition: Improper/Lack of Maintenance
Due 14 December 2010
Resolved 8 December 2010
Resolution: New Coast Pilot obtained.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 December 2010 Resolved
Acquire updated tides and current tables.
Due 14 December 2010
Resolved 15 December 2010
Resolution: New tides and current tables for 2011 were acquired.
Communications › Visual Communication › Warning Sign (gangway)
Issued 7 December 2010 Resolved
Label on pilot house door number of PFDs located inside.
Due 14 December 2010
Resolved 8 December 2010
Resolution: Number of PFDs in pilot house labeled correctly.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2010 Resolved
Aft fuel space bilge alarm (STBD) must be audible and visual.
Condition: Improper/Lack of Maintenance
Due 7 December 2010
Resolved 8 December 2010
Resolution: Aft fuel space bilge alarm (STBD) is a secondary alarm in space and is visual only.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2010 Resolved
Fuel space bilge alarm (STBD) must be audible and visual.
Condition: Improper/Lack of Maintenance
Due 7 December 2010
Resolved 9 December 2010
Resolution: Bilge alarm repaired to be audible and visual.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 7 December 2010 Resolved
Install portable lights in engine spaces.
Due 7 December 2010
Resolved 8 December 2010
Resolution: Portable lights placed at entrance to engine spaces.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2010 Resolved
Forepeak bilge alarm must be audible and visual. (STBD side)
Condition: Improper/Lack of Maintenance
Due 7 December 2010
Resolved 8 December 2010
Resolution: Forepeak alarm repaired to be audio and visual.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2010 Resolved
Aft fuel space bilge alarm must be audible and visual (PORT side)
Condition: Improper/Lack of Maintenance
Due 7 December 2010
Resolved 8 December 2010
Resolution: Aft fuel space bilge alarm is secondary alarm in space and is visual only.
Fire Fighting › Fire Pumps › Bearings
Issued 7 December 2010 Resolved
Replace gasket on fire pump assembly.
Condition: Damaged By Earlier Event
Due 7 December 2010
Resolved 8 December 2010
Resolution: Gasket replaced on fire pump and tested under pressure.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 December 2010 Resolved
Replace inoperable lights on PFDs if they are used and placed in service.
Condition: Improper/Lack of Maintenance
Due 14 December 2010
Resolved 8 December 2010
Resolution: Inoperable lights removed from service.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 December 2010 Resolved
Acquire drill logbook and log drills once every 03 months at a minimum
Due 7 December 2010
Resolved 15 December 2010
Stability › Watertight Integrity › General
Issued 29 October 2010 Resolved
Apply gasket to engine room hatch
Due 29 October 2010
Resolved 29 October 2010
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 29 October 2010 Resolved
Install flame bowl under fuel filter
Due 29 October 2010
Resolved 29 October 2010
Engineering › Bilge Water Management System › Strainer
Issued 29 October 2010 Resolved
Replace stbd sea strainer
Due 29 October 2010
Resolved 29 October 2010
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 5 January 2010 Resolved
Label the life jacket storage boxes' on the upper deck with the number and size of life jackets inside.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 11 March 2010
Resolution: All life jacket lockers properly marked.
Lifesaving › Lifefloat › Float Free
Issued 5 January 2010 Resolved
Life floats were found with canvas covers permanently tied to the life floats, the lines were entangled and did not allow for float free operation. [name withheld] stated that they never removed the covers when the vessel got underway. Remove the covers and do not operate the vessel with the covers installed. Make life floats float free.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2010
Resolved 5 January 2010
Resolution: Mate removed the entangled lines and canvas covers. All Sat.
Engineering › Bilge Water Management System › Valve
Issued 5 January 2010 Resolved
Label bilge suction valves in both port and starboard hulls.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 11 March 2010
Resolution: All valves properly marked.
Stability › Watertight Integrity › General
Issued 5 January 2010 Resolved
Both engine room hatch covers are missing some gasket material and all latches are broken or missing. Renew gaset material as needed and install all new latches. Make hatches watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 February 2010
Resolved 11 March 2010
Resolution: One latch renewed on each hatch, hatches tested ok.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 December 2009 Resolved
bilge alarms do not alarm for correct compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 December 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 February 2009 Resolved
Prove proper operation of audible and visual bilge high level alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2009
Resolved 6 February 2009
Lifesaving › Lifebuoys › Serviceable
Issued 5 February 2009 Resolved
Replace retroreflective tape on lifebuoys.
Due 11 February 2009
Resolved 6 February 2009
Communications › Radio Communications › EPIRB
Issued 5 February 2009 Resolved
Replace hydrostatic release on EPIRB. Vessel is restricted to 3 nm from shore.
Due 5 February 2009
Resolved 6 February 2009
Fire Fighting › Fire Bucket › Quantity
Issued 5 February 2009 Resolved
Obtain 3 fire buckets with lanyards and labeled as FIRE BUCKET.
Due 5 February 2009
Resolved 6 February 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 1 February 2008 Resolved
Prove proper operation of the visual indicator of the bilge high level alarm for the starboard lazarette.
Due 1 February 2008
Resolved 1 February 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 1 February 2008 Resolved
Service all fixed firefighting systems on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2008
Resolved 2 February 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 1 February 2008 Resolved
Service or replace all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2008
Resolved 1 February 2008
Fire Fighting › Fire Hoses › Condition
Issued 1 February 2008 Resolved
Replace fire hose with appropriate size and length.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2008
Resolved 1 February 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 February 2008 Resolved
Label location of first aid kit.
Due 1 March 2008
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Personnel › Training › First Aid/CPR
Issued 1 February 2008 Resolved
Obtain first aid/CPR training for at least 50% of the crew (minimum 2 crew).
Due 1 March 2008
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Fire Fighting › Fire Bucket › Availability
Issued 16 January 2007 Resolved
Obtain 3 fire buckets (labeled with lanyards)
Due 26 January 2007
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 January 2007 Resolved
Make proper repairs to the port and starboard aft engine room visual bilge high level alarms.
Due 19 January 2007
Resolved 20 May 2009
Resolution: Cleared old deficiencies.
Lifesaving › Lifebuoys › Quantity
Issued 25 August 2004 Resolved
Provide (1) ring life buoy for upper deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 August 2004 Resolved
Post life jacket donning placards in conspicuous places throughout the vessel IAW 46 CFR 185.516.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 August 2004 Resolved
Provide current Certificate of Documentation onboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Communications › Alarms/Indicators › High Water Alarm
Issued 25 August 2004 Resolved
Prove proper operation of bilge high water alarms throughout the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Engineering › Bilge Water Management System › Interface Detector
Issued 25 August 2004 Resolved
Label automatic bilge pump indicator lights at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Fire Fighting › Fire Hydrants › Condition
Issued 25 August 2004 Resolved
Provide spanner wrench in way of 2nd deck hose station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Fire Fighting › Fire Hoses › Condition
Issued 25 August 2004 Resolved
Relace fire hose in way of 2nd deck hose station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 August 2004 Resolved
Repair or replace hanle in way of starboard fuel shut-off valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Navigation › Piloting/Steering › US Coast Pilot
Issued 25 August 2004 Resolved
Provide current US Coast Pilot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 August 2004 Resolved
Provide Coast Guard Light List.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 25 August 2004 Resolved
Provide Local Notice to Mariners.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Documentation › Markings/Placards › Capacity Marking
Issued 25 August 2004 Resolved
Mark upper deck with number of passengers allowed per stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Documentation › Markings/Placards › Vessel Number (state)
Issued 25 August 2004 Resolved
Post Emergency Broadcast Placard at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 25 August 2004 Resolved
Post Emergency Instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 August 2004 Resolved
Provide First Aid Kit meet the requirements of 46 CFR 184.710.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Communications › Internal Communications System › Portable Radios
Issued 25 August 2004 Resolved
Prove proper operation of Public Address system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Engineering › Bilge Water Management System › Not Operational
Issued 25 August 2004 Resolved
Prove proper operation of engine driven bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Lifesaving › Lifefloat › Paddle
Issued 25 August 2004 Resolved
Provide paddles for 2 - 22 man lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Lifesaving › Lifefloat › Painter
Issued 25 August 2004 Resolved
Replace lanyards paddles in way of all lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Lifesaving › Lifefloat › Serviceable
Issued 25 August 2004 Resolved
Make repairs to lifefloats using manufacturers approved repair kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Engineering › Bilge Water Management System › Not Installed
Issued 25 August 2004 Resolved
Install automatic bilge pumps in port and starboard lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 25 August 2004 Resolved
Permenantly lock MSD overboard discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 25 August 2004 Resolved
Prove proper operation of starboard engine ignition from pilot house.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 August 2004 Resolved
Conduct fire fighting and man-overboard drills in the presence of a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 January 2005
Resolution: Corrected

Casualty record · 1

20 January 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4230537
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TORTUGA IV (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.