Records from 2012 to 2026. Most recent: inspection, 8 June 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 June 2026
Resolved
Provide an orange or white ring life buoy of at least 24" in diameter with type II retroreflective tape and the vessel's name in capital block letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2026
Resolved 22 June 2026
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 March 2026
Resolved
Refasten the inboard aft deck beam shelf in the starboard engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2026
Resolved
Seal the gap in the starboard engine room's aft bulkhead to make the space vapor tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 March 2026
Resolved
Seal the drain holes on the bottom of the port and starboard collision bulkheads.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 25 March 2026
Resolved
Attach the starboard #3 hatch cover to the hatch frame with a captive chain/cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 25 March 2026
Resolved
Insulate the exposed sections of hot piping on the port and starboard exhaust risers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2026
Resolved 13 April 2026
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 March 2025
Resolved
Provide a visual alarm to indicate a high water level in the starboard lazarette (audible is working).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 8 April 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must be designed with enough capacity for the volume of space it is protecting. Reinstall the original board or provide another means to establish a vapor boundary in non-watertight bulkhead between the port engine room and tank space prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2024
Resolved
Provide an all-round white light to be illuminated when the vessel is at anchor or aground in periods of reduced visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2024
Resolved
Mark the stairs or entry to the upper deck with the maximum number of passengers permitted on the upper deck (Maximum 12 passengers on the upper deck). Marking must be at least 1" numbers and letters.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2024
Resolved
Conduct and log abandon ship, man overboard, and fire fighting drills every three months. Log must contain the date of the drill, a general description, and the individuals in attendance.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 May 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 March 2024
Resolved
There is water ingress around the port tank space hatch. Surrounding wood is waterlogged but not rotted. Dry area and rebed hatch prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 13 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023
Resolved
Life floats are strapped to the top of the house with mooring lines and cleats. Stow all life floats so they can float free prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 15 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 March 2023
Resolved
Provide two paddles of at least 4 feet in each life float and lash each paddle to the life float to witch it belongs prior to operating beyond 3 miles from shore.
Action required: 705 - Other - as specified
Resolved 15 March 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 March 2023
Resolved
Clearly mark the name of the vessel on each life float and each life float paddle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 March 2023
Resolved
Provide one portable hand pump with suitable hose and suction to pump bilge water overboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2022
Resolved
Provide MSC approved Design Verification Test Procedures to show that a loss of power to the electronic propulsion control system does not result in increased shaft speed or propeller pitch. Must be provided prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 March 2022
Resolved
Perform the MSC approved Design Verification Test Procedures without an increase in shaft speed or propeller pitch prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2022
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 September 2020
Resolved
VESSEL SUSTAINED EXTENSIVE DAMAGE TO THE UNDERSIDE OF THE HULL CONNECTING TWO CATAMARAN HULLS TOGETHER IN WAY OF THE MIDSHIP SECTION ON THE PORT SIDE OF THE CENTERLINE. DETERMINE EXTENT OF DAMGE BY REMOVAL OF COMPROMISED FIBERGLASS AND ANY OTHER DAMAGED STRUCTURAL COMPONENTS OF VESSEL. SUBMIT REPAIR PROPOSAL TO OCMI TO RENEW AS ORIGINALLY INSTALLED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTURE.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2020
Resolved 31 January 2022
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 9 December 2019
Resolved
When CG Marine Inspectors conducted a Chemical Testing Program Compliance Audit, it was discovered that the current, credentialed Master onboard the vessel never submitted a pre-employment chemical test prior to hire, and the Owner had no documentation onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 December 2019
Resolved 10 December 2019
Resolution: Refer to Enforcement with a Letter of Warning
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 December 2019
Resolved
Seal all penetrations in the bulkheads from the engine rooms to ensure the proper operation of the FIREBOY system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019
Resolved
All wires and cables in the engine room compartment must be supported every 18 inches with metal brackets lined with a rubber material to prevent chafing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2019
Resolved
Submit plan/specs for install of new generator. After install conduct test of associated fireboy system in the presence of Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 9 December 2019
Resolved
eplace all floating water light batteries with batteries approved for use in waterlights and mark with expiration date (maximum 2 years from date of install)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019
Resolved
Remove or properly cap off all dead end wires.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2019
Resolved
Block off unused openings in the distribution panel at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2019
Resolved
Replace rub rail on port bow to assist in preventing damage tot he hull from impacting the pilling.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 January 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2019
Resolved
Label bilge alarms for the aft fuel space as "not high water alarms".
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 9 December 2019
Resolved
Provide first aid kit with required contents. 160.041
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 December 2019
Resolved
Repair electrical cable to aft anchor light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 October 2019
Resolved
Vessel must have up to date publications on board. Coast Pilot is outdated from 2012.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 January 2019
Resolved
A Pre-engineered Fixed gas fire extinguishing system must automatically shutdown all engines that draw intake within the protected space. Fireboy electrical pigtail was broken and will not shutdown engine upon activation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2019
Resolution: New cylinder installed and operationally tested.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 28 January 2019
Resolved
Demonstrate proper Audible and visual operation of bilge high level alarms in Port/STBD Engine rooms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2019
Resolution: All high level alarms operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 January 2019
Resolved
Demonstrate proper operation of fuel shutoff valve on STBD tank for Engine supply line.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2019
Resolution: Fuel shutoff operates properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019
Resolved
Connect bilge pump conductor wire with a pressure type connector in Port forward compartment. Current connection made with twisting wire and electrical tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Pressure type connector installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 January 2019
Resolved
Repair/replace 22 person Life-floats. Both Life-Floats have sun damage and are no longer international orange.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: Life float painted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019
Resolved
Provide cover for 110 power receptacle under bar.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Cover provided for receptacle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 28 January 2019
Resolved
Provide gaskets for Port and STBD engine room deck hatches. Repair STBD lazarete hatch gasket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Gaskets replaced/repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 January 2019
Resolved
Post all pages of COI (03 pages.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: All pages posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 January 2019
Resolved
Provide current publications (Coast Pilot [name withheld])
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: All publications onboard are up to date.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019
Resolved
AC/DC panel has missing slots, cover to protect against risk of shock.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Missing slots covered on DC/AC panel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 28 January 2019
Resolved
Demonstrate proper operation of visual indicators for automatic bilge pumps (Port forward compartment, Port E/R, STBD aft fuel).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: All visual indicators are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 January 2019
Resolved
Replace watertight container for distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Watertight container provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019
Resolved
Provide a fuse in series (over current protection) for 02 house batteries. Battery cables are an estimated 10 feet from panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2019
Resolution: Over current protection installed at battery terminal (100 amp)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 January 2019
Resolved
Provide means to protect battery terminals from failing objects (Cover or boots).
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Battery terminals covered with box cover.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 28 January 2019
Resolved
Vessel captains did not have a medical certificate. Provide medical certificate to local OCMI and keep with credential.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 February 2019
Resolution: Medical certificate valid for acting captain.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 28 January 2019
Resolved
Vessel captains did not have a FCC radio operator license. Provide FCC radio operator license to local OCMI and keep with credential.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: FCC operator permit provided for acting captain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019
Resolved
Replace hydraulic lines and fittings to reduction gear. Fittings are wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: Hydraulic lines replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019
Resolved
Replace lagging on turbo starboard engine. Lagging deteriorated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: Lagging replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2019
Resolved
[name withheld] stowage locations on main deck with type and number. Old markings were painted over and illegible.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2019
Resolution: All PFD stowage locations marked.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 January 2019
Resolved
Vessel must be equipped with a VHF-DSC radio. Vessel radio was not providing lat and long.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 February 2019
Resolution: GPS input for VHGF radio operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 November 2018
Resolved
Conduct/complete hull examination (drydock), drydock due date listed on current COI is October 31st, 2018. Last credit drydock was completed on October 28th, 2016.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2018
Resolution: Vessel completed credit drydock, updated vessel profile.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018
Resolved
ENSURE THAT BOTH CUTLASS BEARINGS ARE REPLACED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: Cutlass bearings replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 November 2018
Resolved
SEVERAL COMPONENTS ARE NOT PROPERLY GROUNDED INCLUDING BOTH FUEL TANKS. ENSURE NON METALIC FUEL FILL/VENT LINES ARE BRIDGED WITH A BONDING STRAP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2018
Resolution: Fuel tank fills bonded.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2018
Resolved
THE BRIDGE ELECTRICAL PANEL IS SECURED WITH PARACHUTE CORD AND A FISHING HOOK. ENSURE THAT THE PANEL IS PROPERLY SECURED VIA MECHANICAL MEANS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: Lock provided to prevent access to electrical panel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 November 2018
Resolved
ENSURE ALL OVERBOARD DISCHARGE VALVES ARE PROPERLY FUNCTIONING. THE FORWARD STARBOARD BILGE VALVE AS WELL AS SEVERAL ON THE PORT SIDE HAVE SEIZED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: All vales functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2018
Resolved
THE FITTINGS ON THE FUEL LINES RUNNING OUT OF THE STARBOARD TANK HAVE SEVERE CORROSION. ENSURE FITTINGS ARE REPLACED.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2018
Resolution: Fuel lines replaced.
Engineering › Bilge Water Management System › Pump
Issued 14 June 2018
Resolved
Permanently mount all submersible electric bilge pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2018
Resolution: Bilge pumps mounted to hull.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 June 2018
Resolved
Mount high level alarm in STBD laz compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 July 2018
Resolution: High level indicator mounted in Laz compartment.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 6 December 2017
Resolved
Prove operation of starboard Fireboy alarms and shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 December 2017
Resolution: Demonstrated proper operation of system.
Communications › Radio Communications › EPIRB
Issued 6 December 2017
Resolved
Replace expired EPIRB battery.
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 26 December 2017
Resolution: Replaced battery.
Lifesaving › Lifefloat › Serviceable
Issued 6 December 2017
Resolved
Make repairs to starboard lifefloat in accordance with manufacturer's instructions.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 26 February 2018
Resolution: Replaced lifefloat with new.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 December 2017
Resolved
Replace batteries in starboard lifefloat light and lifering light.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Replaced batteries.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 December 2017
Resolved
Replace/update navigational charts and pubs.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 26 December 2017
Resolution: Replaced charts and publications.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 December 2017
Resolved
Input GPS to the VHF radio
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 8 December 2017
Resolution: Connected vessel's GPS to VHF radio
Communications › Alarms/Indicators › High Water Alarm
Issued 6 December 2017
Resolved
Demonstrate proper operation of port fuel tank compartment high level alarm and automatic bilge pump indicator.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Demonstrated proper operation of high level alarm and automatic pump indicator.
Engineering › Bilge Water Management System › Pump
Issued 6 December 2017
Resolved
Demonstrate proper operation of installed bilge system.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 14 June 2018
Resolution: Fixed bilge system removed, all spaces have submersible pumps.
Electrical › Electrical Distribution System (service) › Cable
Issued 6 December 2017
Resolved
Remove flexible cord from distribution panel to fire pump. Renew with approved cable.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 14 June 2018
Resolution: Fire pump removed, not required on board.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 6 December 2017
Resolved
Replace broken exterior electrical outlets on back deck.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Replace outlet and properly mounted.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 December 2017
Resolved
Place port engine batteries in tray.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 8 December 2017
Resolution: Placed batteries in battery boxes.
Stability › Watertight Integrity › General
Issued 6 December 2017
Resolved
Make repairs to watertight hatches.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 26 February 2018
Resolution: Watertight hatches repaired.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 December 2017
Resolved
Provide logs of drills and monthly EPIRB tests.
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 26 February 2018
Resolution: Provided log.
Fire Fighting › Fire Pumps › Pressure
Issued 6 December 2017
Resolved
Install pressure gauge on discharge side of fire pump.
Action required: 705 - Other - as specified
Due 12 December 2017
Resolved 14 June 2018
Resolution: Fire pump removed.
Construction/Loadline › Hull › Hull Plating
Issued 25 October 2016
Resolved
Repair hull in way of all Coast Guard marked areas.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Gel coat renewed in way of all marked areas.
Construction/Loadline › Structures › Manhole
Issued 25 October 2016
Resolved
Repair/replace hatch lanyards to below deck spaces.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Hatch lanyards either refitted or replaced.
Construction/Loadline › Hull › Hull Plating
Issued 25 October 2016
Resolved
Repair/replace areas noted by Coast Guard in way of aft ladder to upper deck and bait well.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Floor joint around aft ladder, main deck cleaned of old caulk and glassed over.
Construction/Loadline › Penetrations › Gasket
Issued 25 October 2016
Resolved
Repair/replace gaskets to below deck hatches.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Gaskets to hatches repaired.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 October 2016
Resolved
Coat deck with non skid.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Deck coated with non skid.
Unknown
Issued 25 October 2016
Resolved
Replace zincs.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: All zincs replaced.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 25 October 2016
Resolved
Replace port/starboard cutlass bearings.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Port/starboard cutlass bearings replaced.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 25 October 2016
Resolved
Realign prop shaft.
Action required: 705 - Other - as specified
Resolved 28 October 2016
Resolution: Prop shafts realigned.
Lifesaving › Lifefloat › Serviceable
Issued 11 October 2016
Resolved
Repair/renew lifefloats. Vessel restricted to operating no more than 3 miles from land.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 1 December 2016
Resolution: Procured/installed new lifefloat
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 October 2016
Resolved
Provide floating waterlight for lifebuoy. Vessel restricted to daytime operations.
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 11 October 2016
Resolution: Provided light
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 October 2016
Resolved
Provide lifeline for lifebuoy
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 October 2016
Resolved 11 October 2016
Resolution: Renewed line
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 October 2016
Resolved
Reinstall access cover to port engine room forward bulkhead
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2016
Resolution: reinstalled and sealed access cut out in bulkhead
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 October 2016
Resolved
Properly secure starboard engine room batteries to satisfaction of attending marine inspector
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 8 November 2016
Resolution: Installed new straps to secure battery
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 October 2016
Resolved
Post COI and Stability letter
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 16 October 2016
Resolution: Posted all pages of COI and Stability Letter.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 October 2016
Resolved
Post PFD donning placards on upper deck
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 8 November 2016
Resolution: Posted donning instructions on second deck
Personnel › Certificates/Documents/Licenses › License, Master
Issued 11 October 2016
Resolved
Provide master's credentials
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2016
Resolution: Provided credentials
Communications › Alarms/Indicators › High Water Alarm
Issued 11 October 2016
Resolved
Repair/renew the following: High level alarms for port and stbd forepeak, automatic bilge pump indicators for port and stbd aft fuel tank spaces and port laz
Action required: 705 - Other - as specified
Due 11 November 2016
Resolved 1 December 2016
Resolution: Proved proper operation
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 October 2016
Resolved
Demostrate proper operation of engine shutdowns for port and starboard pre-engineered fire extinguishing systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2016
Resolution: Demonstrated proper operation of systems shutting down all engines
Documentation › Certificates/Documents › FCC SSL
Issued 12 January 2016
Resolved
Vessel did not have FCC radio station license that identified it was for the TORTUGA IV
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: New SSL provided
Documentation › Certificates/Documents › Stability Letter
Issued 12 January 2016
Resolved
COI and Stability letter were not posted visible to passengers.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: Items posted
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 January 2016
Resolved
Vessel did not have company drug testing policy on board and available to review.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: program provided.
Engineering › Bilge Water Management System › Not Operational
Issued 12 January 2016
Resolved
Bilge high level water alarm in starboard void was inoperable.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: proved proper operation
Lifesaving › Hand Flares › Quantity
Issued 12 January 2016
Resolved
Vessel had only 8 of required 12 flares
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: Additional flares provided
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 January 2016
Resolved
Life Float light battery was dead. Replace battery.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: battery replaced.