MAURY USCG vessel records Sign in
← All vessels

MISS SUZANNE

MISS SUZANNE is a 2002 offshore supply vessel. The Coast Guard has recorded 12 inspections since 2002, most recently in November 2008, along with 12 deficiencies and 1 casualty investigation in 2009.

Records from 2002 to 2009. Most recent: casualty investigation, 16 May 2009.

Built
2002
Last inspected
19 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8975213 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD3505
579986
Flag
UNITED STATES
366880890, 367132360 (licence lapsed)
Maury page id
psix-579986

Inspections, by type

…with no type recorded3
Years with a record 7 calendar years (2002–2008)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
322 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
96 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD3505MMSI 367132360 · expired · compulsorily equipped · granted 29 July 2006, cancelled 1 October 2016
WDB2879MMSI 366880890 · expired · compulsorily equipped · granted 5 February 2003, cancelled 8 April 2013 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 12

19 November 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3363112
23 October 2008 Administrative Inspection · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3349946
7 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3051981
22 March 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2607525
6 February 2006 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2593944
15 November 2005 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2531844
25 July 2005 Damage Survey
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2438949
16 August 2004 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2140268
26 September 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1913876
8 July 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1841603
10 May 2003 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1868680
23 August 2002 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1735051

Deficiency record · 12

Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 November 2008 Resolved
Obtain and maintain current Tides and Currents tables onboard.
Due 12 December 2008
Resolved 19 May 2009
Resolution: Obtained current tables.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 12 November 2008 Resolved
Obtain and maintain current Light list onboard.
Due 12 December 2008
Resolved 22 May 2009
Resolution: Owner of vsl presented 2009 Light List to USCG Marine Inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 November 2008 Resolved
Vessels drydock hull exam was due on 01 Aug 2008. Vessel continues to work until 20 Oct 2008. Vessel was not made available for drydock.
Action required: 705 - Other - as specified
Resolved 19 May 2009
Resolution: Received drydock credit in Nov 08.
Communications › Radio Communications › EPIRB
Issued 11 November 2008 Resolved
Hydrostatic release for EPIRB is expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Resolution: New Hydrostatic release installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 23 October 2008 Resolved
Vessel must obtain and have onboard alcohol test strips for crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2008
Resolution: New Alcohol test strips installed onboard.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 November 2005 Resolved
Provide additional e-lights in engine room.
Condition: Unknown
Due 15 December 2005
Resolved 15 November 2005
Construction/Loadline › Penetrations › Gasket
Issued 15 November 2005 Resolved
Install proper gaskets on three wtds
Condition: Unknown
Due 15 December 2005
Resolved 15 November 2005
Construction/Loadline › Structures › Ventilators
Issued 25 July 2005 Resolved
Prior to sailing install permanent patch over aft starboard ventalation housing unit to prevent flooding of engine compartment to the satisfaction of local OCMI.
Condition: Unknown
Due 25 July 2005
Resolved 25 July 2005
Resolution: Repairs made.
Construction/Loadline › Structures › Ventilators
Issued 25 July 2005 Resolved
Vessel must make permanent repairs by placing an insert on the aft starboard ventalation housing unit during next scheduled drydock to the satisfaction of local OCMI.
Due 16 August 2006
Resolved 7 September 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 8 July 2003 Resolved
Install wood or rubber between steel CO2 bottles and aluminum platform. Evidence of galvanic corrosion occurring.
Due 8 August 2003
Resolved 16 August 2004
Resolution: Installed rubber under bottles, replaced two bottles.
Engineering › Steering Gear System › Ram
Issued 8 July 2003 Resolved
Adjust steering to prevent rams from hitting stops.
Due 8 August 2003
Resolved 16 August 2004
Resolution: Adjusted steering rams.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 July 2003 Resolved
Repair or replace lazarette hatch cover.
Due 8 August 2003
Resolved 16 August 2004
Resolution: Repaired hatch.

Casualty record · 1

16 May 2009Routine · role: Involved in a Marine Casualty · activity 3494926
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.