Inspection history · 20
21 April 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8354190
18 August 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8120293
14 March 2025
Damage Survey · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8091163
7 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7895993
25 April 2024
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7886537
25 May 2023
Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7656513
6 April 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7674810
6 April 2022
Drydock Exam · Annual Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7416413
17 September 2021
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7316981
11 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7199142
24 May 2021
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7201987
22 October 2020
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7082191
7 May 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6945505
6 June 2019
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6706634
30 January 2019
Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6617581
5 June 2018
COI Inspection · Deficiency Check · Internal Structural Exam · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6392707
10 April 2018
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6388720
22 November 2016
Administrative Inspection · Plan Review "T" Boat · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6046533
13 June 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5906124
9 February 2016
Drydock Exam · Administrative Inspection · Internal Structural Exam · Hull Examination · Re-Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5814327
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 June 2024
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. The audible alarm at the operating station was not working.
Action required: 10 - Deficiency Rectified
Resolved 7 June 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 June 2023
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge. Crew unable to locate/test high water alarm in engine space. Locate and demonstrate alarm to CG marine inspector. Till high water alarm is found/tested, conduct 30 minute rounds while underway and log rounds in logbook.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 June 2023
Resolution: High water alarm tested
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 June 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clear legible letters at least 2" high: "EMERGENCY EXIT, KEEP CLEAR".
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 June 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 5 June 2023
Resolved
Credentialed master's medical certificate expired, thus making MMC invalid. Obtain updated medical certificate prior to operating as vessel master.
46 CFR 11.201
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 16 June 2023
Resolution: Med cert provided
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 17 September 2021
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape incase of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel expected a collision with a center console boat while moored. Impacting vessel affected an approximately 3" by 1/4" deep divot on the BELLE's port side, approximately 4 feet above the waterline and 3-4' aft of the centerline. Conduct periodic rounds over the next 24 hours, and report any changes in the vessel's condition to the OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2021
Resolved 17 September 2021
Resolution: Vessel provided photographic documentation and information demonstrating minimal cosmetic damage to the satisfaction of the reviewing Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 June 2021
Resolved
Man overboard drill failed. Demonstrate MOB drill to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2021
Resolved
Prove proper operation of remote fuel shutoff valve for the port MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 June 2021
Resolved
Prove proper operation of CO2 pressure switch for SSDG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 June 2021
Resolved
Provide alcohol test strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 June 2021
Resolved
Provide FCC safety radio and bridge to bridge certificates.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 June 2021
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 11 June 2021
Resolved
Provide emergency instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 June 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 October 2020
Resolved
Vessel missed Annual Inspection due to COVID-19. Complete Annual Inspection prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2019
Resolved
Provide MSC plan approval for installation of the bow thruster.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2019
Resolved 12 June 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 June 2019
Resolved
Prove full compliance of crew and master of drug and alcohol program. Consortium states in "hold status".
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: All crew are enrolled in DAPI program / pre employment test completed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 June 2019
Resolved
Master did not have a marine operators permit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: Completed requirement for operators marine radio permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 6 June 2019
Resolved
Vessel did not have a FCC safety Radio or Bridge to Bridge certificates onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: FCC safety and bridge to bridge certificates on vessel to expire 6/10/2024.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 June 2019
Resolved
Vessel's Coast Pilot [name withheld], Tide Tables, and Charts were out of date. Provide new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: Excerpts of coast pilot, light list, tide / currents tables and print on demand chart updated to April 2019 on vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 6 June 2019
Resolved
Alcohol test kits were expired. Provide new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: New test strips on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 June 2019
Resolved
Provide life jacket donning placard for all types of life jackets carried onboard.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: New donning placards installed on vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 June 2019
Resolved
First aid kit does not meet 160.041 list of contents. Provide missing contents and correct quantity.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: First aid kit and contents meet regulatory requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2019
Resolved
Ring buoys did not have vessels name, stencil vessel's name on ring buoys.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: Ring buoys labeled BELLE.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 6 June 2019
Resolved
Embarkation area at vessel's port and stbd side amidships did not have the required 4" courses at the rails.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2019
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 June 2019
Resolved
Original COD was not onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2019
Resolved 10 June 2019
Resolution: Original COD is on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 June 2018
Resolved
updated nav charts, 13218 / 13237
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2018
Resolved 10 June 2018
Resolution: Confirmation of new charts supplied.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 June 2018
Resolved
Publication to cover tides, tide tables, currents for 2018.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2018
Resolved 10 June 2018
Resolution: Nautical publications provided for current year 2018.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 June 2018
Resolved
Fire pump seal leaking excessive.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2018
Resolved 10 June 2018
Resolution: New seal installed and tested sat 60 psi.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 March 2017
Resolved
Complete full inspection for certification prior to carrying passengers. Vessel is currently in laid up status.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 7 June 2018
Resolution: Completed inspection, issued Temp COI
Construction/Loadline › Structures › Scuttle
Issued 13 June 2016
Resolved
Install retaining lanyards/leashes on Laz and forepeak hatch accesses.
Condition: Improper/Lack of Maintenance
Due 16 June 2016
Resolved 16 June 2016
Resolution: Installed retaining lanyards/leashes on Laz and forepeak hatch accesses
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 13 June 2016
Resolved
Provide current Certificate of Documentation.
Condition: Placed in Improper Service
Due 16 June 2016
Resolved 16 June 2016
Resolution: Provided current Certificate of Documentation.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 June 2016
Resolved
Provide proof of all members enrolled in companies drug and alcohol program with the proper status.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 June 2016
Resolved
Provide new alcohol test kits.
Condition: Improper/Lack of Maintenance
Due 16 June 2016
Resolved 16 June 2016
Resolution: Provided new alcohol test kits.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 June 2016
Resolved
Enter MMSI on radio.
Condition: Placed in Improper Service
Due 16 June 2016
Resolved 16 June 2016
Resolution: Entered MMSI on radio.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 13 June 2016
Resolved
Provide current fire servicing report.
Condition: Invalid
Due 16 June 2016
Resolved 16 June 2016
Resolution: Provided current fire servicing report.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 June 2016
Resolved
Repair/ replace starboard running light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Repaired starboard running light.
Communications › Radio Communications › EPIRB
Issued 13 June 2016
Resolved
Provide current NOAA registration.
Condition: Improper/Lack of Maintenance
Due 16 June 2016
Resolved 16 June 2016
Resolution: Provide current NOAA registration.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 June 2016
Resolved
Correct lifejacket stowage and markings to identify quantity and size
Condition: Placed in Improper Service
Due 16 June 2016
Resolved 16 June 2016
Resolution: Corrected lifejacket stowage and markings to identify quantity and size
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 13 June 2016
Resolved
Provide proper lifejacket donning placards in the vicinity of lifejacket stowage.
Condition: Placed in Improper Service
Due 16 June 2016
Resolved 16 June 2016
Resolution: Provided proper lifejacket donning placards in the vicinity of lifejacket stowage.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 June 2016
Resolved
Prove proper operation of bilge alarms in laz and engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2016
Resolution: Proved proper operation of bilge alarms in laz and engine room.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 June 2016
Resolved
Prove proper operation of ring buoy water light.
Condition: Improper/Lack of Maintenance
Due 16 June 2016
Resolved 16 June 2016
Resolution: Proved proper operation of ring buoy water light.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 13 June 2016
Resolved
Properly store fire extinguisher in galley.
Condition: Improper Installation
Due 16 June 2016
Resolved 16 June 2016
Resolution: Properly stored fire extinguisher in galley.
Stability › Watertight Integrity › General
Issued 13 June 2016
Resolved
Properly mark watertight door and prove operation of installed alarm.
Condition: Improper/Lack of Maintenance
Due 16 June 2016
Resolved 16 June 2016
Resolution: Properly marked watertight door and proved operation of installed alarm.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 June 2016
Resolved
Properly mount fire extinguisher in aft head.
Condition: Improper Installation
Due 16 June 2016
Resolved 16 June 2016
Resolution: Properly mounted fire extinguisher in aft head.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2016
Resolved
Conduct operational bilge pump test.
Condition: Invalid
Due 16 June 2016
Resolved 16 June 2016
Resolution: Conducted operational bilge pump test.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 13 June 2016
Resolved
Conduct operational engine test.
Condition: Invalid
Due 16 June 2016
Resolved 16 June 2016
Resolution: Conducted operational engine test.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 June 2016
Resolved
Conduct underway drills.
Condition: Invalid
Due 16 June 2016
Resolved 16 June 2016
Resolution: Conducted underway drills.
Fire Fighting › Fire Main › Material
Issued 13 June 2016
Resolved
Properly replace the broken elbow for the gauge.
Action required: 705 - Other - as specified
Due 16 June 2016
Resolved 16 June 2016
Resolution: Corrected prior to departure.