13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 26 August 2020
Resolved
Properly mount hydraulic ram to starboard rudder pedestal. Due prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 September 2020
Resolution: Hardware replaced, operationally tested SAT.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 26 August 2020
Resolved
Prove proper operation of machinery space escape and aft cabin water-tight door alarms. Due 09Sep2020.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2020
Resolved 7 October 2020
Resolution: Visually inspected onboard vessel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 August 2020
Resolved
Cap abandoned fuel pipe in way of starboard side main engine shaft coupling. Due 25Sep2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 2 September 2020
Resolution: Capped.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 August 2020
Resolved
Repair exhaust leak on port main engine. Due 09Sep2020.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2020
Resolved 7 October 2020
Resolution: Visually inspected onboard vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020
Resolved
Properly mount pump on starboard side engine room located in cabinet. Due 25Sep2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 2 September 2020
Resolution: Mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020
Resolved
Properly install junction box covers located behind port main engine. Due 25Sep2020.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2020
Resolved 7 October 2020
Resolution: Visually inspected onboard vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 26 August 2020
Resolved
Remove dead rat from below deck toilet space. Due prior to carriage of passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2020
Resolution: Removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 August 2020
Resolved
Label machinery space escape "EMERGENCY EXIT, KEEP CLEAR". Due 09Sep2020.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2020
Resolved 7 October 2020
Resolution: Visually inspected onboard vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 August 2020
No resolution recorded
Make aft bulkhead in engine room water/vapor tight. Due 25Sep2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2020 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 27 August 2019
Resolved
Provide valid FCC Safety Certificate.
47 CFR 13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 24 September 2019
Resolution: FCC Radio cert provided.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 27 August 2019
Resolved
Conduct MOB and fire drill quarterly. Drills not being completed/logged quarterly.
46 CFR 185.520(f)
Action required: 10 - Deficiency Rectified
Due 27 August 2019
Resolved 27 August 2019
Resolution: Drills logged.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 August 2019
Resolved
Remove dead end wire. Dead end wire in pilothouse overhead.
46 CFR 183.340
Action required: 10 - Deficiency Rectified
Due 27 August 2019
Resolved 27 August 2019
Resolution: Dead end wires removed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 27 August 2019
Resolved
Make STBD water temp gauge operational. STBD water temp gauge not functioning properly.
46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 24 September 2019
Resolution: Water temp gauge operational.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 August 2019
Resolved
Replace lagging on stack in upper compartment.
46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 24 September 2019
Resolution: Lagging replaced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 August 2019
Resolved
Secure upper deck fire main piping.
46 CFR 181.20-20(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 29 August 2019
Resolution: Added U bracket to secure fire piping.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 August 2019
Resolved
Remove non-combustible fuel tank sight glass.
46 CFR 182.20-25(c)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 24 September 2019
Resolution: Sight glass removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2019
Resolved
Provide cover for electrical outlet in liquor locker.
46 CFR 183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 29 August 2019
Resolution: Provided outlet cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 August 2019
Resolved
Make Generator interlock panel tight.
46 CFR 183.322(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 24 September 2019
Resolution: Interlock made tight.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 August 2019
Resolved
Remove and replace sealant for engine room WTD cable raceway with marine grade sealant with fire rating.
46 CFR 179.320(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 24 September 2019
Resolution: Marine grade sealant installed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 August 2019
Resolved
Add WTD indicator light/alarm for WTD on aft bulkhead of engine room that enters into stateroom head.
46 CFR 179.330(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 24 September 2019
Resolution: Indicator added for WTD.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
ZERO DRAFT: no static draft information, SHIP TYPE MISSING: Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 December 2018
Resolution: Verified in VIVS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018
Resolved
Repair damaged structure (cracks) to steering gear.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2018
Resolved 10 August 2018
Resolution: Structure stiffened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018
Resolved
Install rudder stops to steering gear.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2018
Resolved 10 August 2018
Resolution: Internal stops on new hydraulic rams.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 8 August 2018
Resolved
Repair water tight door indicators and adjust aft door dogs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 22 August 2018
Resolution: Items corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018
Resolved
Replace poret side battery box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 10 August 2018
Resolution: New box installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2018
Resolved
Correct the following wire issues: Nav stern light loose, wiring bundles not supported aft of stbd engine, wiring in bilge aft E/R, broken switch cover in galley, aft battery charger cover.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 22 August 2018
Resolution: Items corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 8 August 2018
Resolved
Prevent dishwasher from movement.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 22 August 2018
Resolution: Item corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 8 August 2018
Resolved
Repair loose stanchion at crew ladder stbd side near pilot house.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 22 August 2018
Resolution: Item corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 August 2018
Resolved
Replace rubber hose on bilge pipe at lazarette pickup.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2018
Resolved 22 August 2018
Resolution: Item corrected.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 September 2016
Resolved
Install indicators for all watertight doors and prove operation. Indicators must be located in the pilothouse and must show wether the door is open or closed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2016
Resolved 3 October 2016
Resolution: The alarms were installed and tested; all sat
Electrical › Electric Generation Source (service) › Panelboard
Issued 1 September 2016
Resolved
Install non-conducting mat or grating on deck in front of the main switchboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 3 October 2016
Resolution: Non conductive mats was in front of panelboard.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 September 2016
Resolved
Make forward engine room bulkhead watertight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 3 October 2016
Resolution: Forward engine room watertight
Engineering › Steering Gear System › Interlock
Issued 1 September 2016
Resolved
Make effective repairs to the steering system and prove proper operation
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 October 2016
Resolution: Steering system was properly repaired and tested.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 23 July 2016
Resolved
Renew starter on starboard main propulsion engine and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2016
Resolution: Starter renewed and tested
Electrical › Electric Supply System (service) › Battery Conductor
Issued 23 July 2016
Resolved
Renew battery selector switch for starboard main propulsion engine and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2016
Resolution: Battery selector switch renewed and tested.