Records in 2002. Most recent: operational control imposed, 23 July 2002.
Documentation record
Tonnage as PSIX records it1613 - Convention (Subpart B), Net Ton
6063 - Displacement, Ton
4495 - Dead Weight, Ton
1613 - Regulatory (Subpart C or D), Net Ton
2916 - Convention (Subpart B), Gross Ton
2916 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
23 July 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1651019
22 July 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1652436
16 July 2002
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1647004
16 July 2002
Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1677172
Navigation › Electronic Positioning
Issued 23 July 2002
Resolved
Repair Echo Depth Sounder at the next drydock. LEGACY COMPONENT DESC: Echo Depth Sounder
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 October 2002
Resolved 30 October 2002
Resolution: Requirement enter in duplicate under acty 1647004.
Fire Fighting › International Shore Connection
Issued 16 July 2002
Resolved
Provide an international shore connection.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 23 July 2002
Resolution: Connection located in the electrical room spaces and transfer to its normal location at the bridge.
Construction/Loadline › Markings › Load Line Mark
Issued 16 July 2002
Resolved
Paint load line port and starboard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2002
Resolution: Loadline painted.
Personnel › Training › Fire Fighting Basic
Issued 16 July 2002
Resolved
Conduct fire drill to satisfaction of class and US Coast Guard Marine Inspector.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2002
Resolution: Fire drill satisfactory done and witnessed by class surveyor and marine inspector.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 16 July 2002
Resolved
Provide proof of comapany ISM internal audit records.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2002
Resolution: Documents faxed to MSO San Juan and accepted as evidence.
Navigation › Piloting/Steering
Issued 16 July 2002
No resolution recorded
Properly calibrate rudder angle indicator to give accurate readouts between bridge and steering room by next drydock and prior next US Port.
Condition: Unknown
Due 30 October 2002 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 16 July 2002
No resolution recorded
Repair depth sounding device at next drydock.
Condition: Damaged By Earlier Event
Due 30 October 2002 — due date passed with no resolution recorded
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 16 July 2002
Resolved
Warning statement was missing.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2002
Resolution: Corrected on the spot.
Operations/Management › Drills/Instruction › Fire
Issued 16 July 2002
Resolved
Crew unable to perform a satisfactory fire drill in accordance with SOLAS or vessel's ISM proceedures.
Condition: Improper/Lack of Maintenance
Due 16 July 2002
Resolved 23 July 2002
Resolution: Witnessee satisfactory drills class in attendance.