MAURY USCG vessel records Sign in
← All vessels

MAC-WAY I

MAC-WAY I is a 1967 freight ship. The Coast Guard has recorded 49 inspections since 2002, most recently in February 2024, along with 69 deficiencies and 29 operational controls.

Records from 2002 to 2024. Most recent: inspection, 28 February 2024.

Built
1967
Last inspected
28 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6719952 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
581910
Flag
HONDURAS
—
Maury page id
psix-581910

Inspections, by type

…with no type recorded33
Years with a record 7 calendar years (2002–2024)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it299 - Regulatory (Subpart C or D), Gross Ton
824 - Convention (Subpart B), Gross Ton
325 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 49

28 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7871758
6 December 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3097469
10 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3096243
8 November 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3095465
22 May 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2937241
4 May 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2922094
1 May 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2919910
30 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2919269
4 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2901785
2 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2899839
24 October 2006 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2806955
20 October 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2804654
19 October 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2803563
23 July 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2721691
17 June 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2682395
11 May 2006 ISPS II Exam · PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2646331
9 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2644651
4 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2616065
9 January 2006 Random ISPS/MTSA/PSC · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563252
4 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2560883
9 December 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2548592
5 December 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2548578
28 November 2005 ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2541799
26 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2540961
26 September 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2501751
23 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2499681
21 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2497642
23 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2436334
29 June 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2407669
13 June 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2388757
6 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2381911
19 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2338533
17 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2335933
14 March 2005 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2309588
9 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2307066
6 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2304520
21 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2297479
18 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2294973
1 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2210644
2 August 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2153244
30 July 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2150408
16 July 2004 Type not recorded
No type recorded · GROUP MIAMI · USCG Southeast District (CGD-SE) · Activity 2134954
16 July 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2135525
3 June 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2087338
31 October 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1939737
28 October 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1937689
18 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1776006
25 March 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1762616
17 July 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1647558

Deficiency record · 69

Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 November 2007 Resolved
Vsl does not meet Minimum Safe Manning Document requirements as do not have a Chief Mate and Able Seamen.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Lifesaving › Inflatable Liferafts › Approval
Issued 13 November 2007 Resolved
Life raft servicing overdue. Vsl is to provide Sector Miami with a receipt verifying servicing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Construction/Loadline › Markings › Load Line Mark
Issued 13 November 2007 Resolved
Vsl's load line is not permanently affixed and marked in accordance with Int'l load line certificate.
Action required: 705 - Other - as specified
Due 27 November 2007
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 13 November 2007 Resolved
Minimum Safe Manning Document and Certificate of Registry to expire on 14NOV07. Provide Sector Miami with updated documents.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 13 November 2007 Resolved
Vsl's main steering gear loss of power alarm is inoperable on the bridge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 13 November 2007 Resolved
Vsl infested with dirty parasites. Fumigate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 13 November 2007 Resolved
CCSSC does not have annual endorsements or a dry dock endorsement. Vsl is not permitted to load cargo until a valid certificate is provided.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 13 November 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 13 November 2007 Resolved
Provide class report attesting to the structural integrity of the rescue boat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 13 November 2007 Resolved
CCSSC did not meet two inspections of the outside of the ship's bottom within the five year period as required per regulations.
Action required: 705 - Other - as specified
Due 6 January 2008
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 2007. From activity: 3097469. Inactivated vessel due to no activity for 17 years.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 4 May 2007 Resolved
Emergency fire pump suction hose not operational, therefore e fire pump is not operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2007
Resolved 22 May 2007
Lifesaving › Rescue Boat › Propulsion Engine
Issued 4 May 2007 Resolved
Rescue boat motor is leaking fuel and is under repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2007
Resolved 22 May 2007
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 4 May 2007 Resolved
M/E F/W cooling pipe was missing and under repair.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2007
Resolved 22 May 2007
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 4 May 2007 Resolved
E generator voltage meter is broken
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2007
Resolved 22 May 2007
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 4 May 2007 Resolved
Firefighting suits are not approved for direct entry and does not protect against steam scalding.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2007
Resolved 22 May 2007
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 4 May 2007 Resolved
Provide servicing reports for fire extinguishers and breathing apparratus
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2007
Resolved 22 May 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 October 2006 Resolved
REPLACE BATTERIES IN ALL SMOKE DETECTORS
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2006
Resolved 15 November 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 24 October 2006 Resolved
Overhead light in forward compartment has exposed wiring, potential fire hazard.
Action required: 705 - Other - as specified
Due 24 November 2006
Resolved 15 November 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2006 Resolved
Electrical wiring in forward compartment exposed and is a potential fire hazard.
Action required: 705 - Other - as specified
Due 24 November 2006
Resolved 15 November 2006
Engineering › Lubricating Oil Service System › Manifold
Issued 24 October 2006 Resolved
There is an oil leak in generator in forward compartment. Make repairs to the satisfaction of flag.
Action required: 705 - Other - as specified
Due 24 November 2006
Resolved 15 November 2006
Personnel › Certificates/Documents/Licenses › STCW Certificate, Chief Mate
Issued 11 May 2006 Resolved
Provide STCW endorsement for Chief Mate
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 6 July 2006
Electrical › Electric Generation Source (service) › Generator
Issued 11 May 2006 Resolved
Install cover for battery on generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2006
Resolved 6 July 2006
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 11 May 2006 Resolved
Reservice hydrostatic release unit on liferaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 6 July 2006
Documentation › Certificates/Documents › International Load Line Certificate
Issued 11 May 2006 Resolved
Provide annual survey of load line.
Action required: 705 - Other - as specified
Due 11 May 2006
Resolved 6 July 2006
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 11 May 2006 Resolved
Fumigate galley, kitchen, cook's quarters, other areas where roach infestation present. Provide proof in form of receipts for pesticide or exterminator.
Action required: 705 - Other - as specified
Due 25 May 2006
Resolved 6 July 2006
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 9 January 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2006
Resolution: Received via fax proof of application for flag state endorsement for the Chief engineer.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 5 December 2005 Resolved
Vessel failed to provide an update to its ANOA. Vessel arrived in port one day early.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2006
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 28 November 2005 Resolved
Vessel's master is not familiar with vessel's safety management system, particularly, emergency procedures.
Action required: 705 - Other - as specified
Due 9 January 2006
Resolved 9 January 2006
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 26 September 2005 Resolved
Vessel's Interim DOC has expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2005
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 26 September 2005 Resolved
Vessel's SMC has expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2005
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 26 September 2005 Resolved
Caribbean Cargo Ship Safety Certificate has not been endorsed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2005
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 26 September 2005 Resolved
Caribbean Cargo Ship Safety Certificate does not have the proper dry dock dates listed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 October 2005
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 26 September 2005 Resolved
Operating company listed on the DOC and the SMC does not match the operating company listed on the ISSC and the CSR.
Action required: 15 - Rectify deficiencies by next port
Resolved 14 October 2005
Engineering › Steering Gear System › Power Unit
Issued 26 September 2005 Resolved
No steering gear alarm is available on bridge to indicate loss of power.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2005
Resolved 7 November 2005
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 26 September 2005 Resolved
Paint stores are located in bosun stores/machine shop with equipment that creates a fire hazard. Have flag State rep address storage of flammable liquids (paint) and provide recommendation/attestation for proer arrangement.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 October 2005
Resolved 7 November 2005
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 13 June 2005 Resolved
Chief Mate missing Flag state endoursement. Provide proof of endoursement.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 28 June 2005
Resolution: Received copy of endorcement.
Engineering › Fuel Oil Service System › Piping
Issued 14 March 2005 Resolved
Fuel line in the rear of the emergency genarator is loose and leaking.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2005
Navigation › Collision/Grounding Avoidance › Transponder
Issued 14 March 2005 Resolved
EPIRB is missing from the bridge.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2005
Construction/Loadline › Penetrations › Weld
Issued 14 March 2005 Resolved
Insert located portside of the forepeak. Watertight integrity is not sound.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2005
Construction/Loadline › Structures › Deck Plating
Issued 14 March 2005 Resolved
Deck in emergency gen room is wasted
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2005
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 14 March 2005 Resolved
Provide current tide tables.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 31 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 August 2004 Resolved
Reefer on port side bridge wing is unsecured and improperly wired. Make permanent/proper configuration for securing reefer and properly wire.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 2 August 2004 Resolved
Liferaft on starboard side has expired hydrostatic release. Replace expired hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Communications › Radio Communications › EPIRB
Issued 2 August 2004 Resolved
EPIRB has expired battery. Replace battery for EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 2 August 2004 Resolved
Sea chest is wasted and holed. Make permanent/proper repair (crop and renew).
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Fire Fighting › Fire Main › Condition
Issued 2 August 2004 Resolved
Fire main in upper level engine room has temporary repair (soft patches). Make permanent/proper reapairs (crop and renew).
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Electrical › Electric Generation Source (emergency) › Generator
Issued 2 August 2004 Resolved
Emergency and No. 2 Generators are inoperable due to depleted starting batteries. Make permanent/proper reapirs to both generators.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 2 August 2004 Resolved
Rudder angle indicator does not accurately reflect position of rudder. Repair
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 August 2004 Resolved
Seawater line from sea chest to main engine is wasted and holed. Make permanent/proper repairs to piping (crop and renew).
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 August 2004 Resolved
Seawater discharged piping from main engine is holed and wasted. Make permanent/proper repair to discharge piping (crop and renew).
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 2 August 2004 Resolved
No. 1 generator has imporper fuel lines (not fuel rated). Replace fuel lines with proper rated lines.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 2 August 2004 Resolved
Main engine has exhaust leak. Permanently repair main engine to eliminate exhaust leak.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Operations/Management › Pollution › Retention of Oily Mixture
Issued 2 August 2004 Resolved
Vessel has a high level of oily water mixture in bilge. Properly remove oily water from bilge. Provide Sector Miami with prrof of disposal via fax.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2004
Resolved 11 August 2004
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 2 August 2004 Resolved
Prior to loading cargo and prior to departure, provide a written repair proposal to make permanent and proper repairs to main sea chest in engin room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2005
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 2 August 2004 Resolved
Prior to next US port of call after sailing foreign, make proper repairs to sea chest to the satifaction of flag administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 August 2004
Personnel › Certificates/Documents/Licenses › STCW Certificate, Advance Fire Fighting
Issued 3 June 2004 Resolved
Oiler's Basic Training (STCW-Safety) have expired. Oiler must renew Basic Safety training, apply for "Letter of Dispensation", or be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2004
Resolved 18 June 2004
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 3 June 2004 Resolved
Chief Engineer does not have flag State endorsement. Provide endorsement or proof of application.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 June 2004
Resolved 18 June 2004
Engineering
Issued 31 October 2003 Resolved
Repair all items on [name withheld] worklist dated 22 Oct 2003.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Personnel › Manning/Qualifications
Issued 31 October 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Engineering › Generator (propulsion-electric)
Issued 31 October 2003 Resolved
Provide proper fuel line connections on main generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 31 October 2003 Resolved
Repair all remote fuel shut-off valves on engine room. LEGACY COMPONENT DESC: Valve
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Deck/Cargo
Issued 31 October 2003 Resolved
Provide proper embarkation ladders on port & Stbd. embarkation decks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2004
Personnel › Manning/Qualifications
Issued 25 March 2003 Resolved
Chief Mate was not on board for inspection of license and endorsement. LEGACY COMPONENT DESC: Minimum Safe Manning
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2003
Fire Fighting › Fire Main
Issued 25 March 2003 Resolved
Two leaks were observed in the firemain. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2003
Construction/Loadline › Structures
Issued 25 March 2003 Resolved
A Watertight door is missing in the forepeak storeroom. This open space is directly exposed to the weatherdeck. The door was apparently removed due to tonnage calculations. Flag state is to provide reasoning attesting to entrance of space not needing a door. LEGACY COMPONENT DESC: Machinery Space Opening
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2003
Stability › Watertight Integrity
Issued 25 March 2003 Resolved
Watertight hatches in focsle (amidships and starboard side near entrance to forepeak stores) are not watertight. Make adjustments to dogs/replace gaskets as needed.
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 6 May 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 25 March 2003 Resolved
Shut off valves for emergency generator are inoperable. Make repairs to satisfaction of the flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2003
Electrical › Electric Generation Source (emergency)
Issued 25 March 2003 Resolved
Properly remove/end dead end wires in fwd generator room between emergency and secondary generator room. LEGACY COMPONENT DESC: Wires
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 6 May 2003
Operations/Management › Drills/Instruction
Issued 25 March 2003 Resolved
Conduct Fire and Abandon Ship drills in the presense of a CG Marine Inspector. LEGACY COMPONENT DESC: Fire/Abandon Ship
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 May 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.