MAURY USCG vessel records Sign in
← All vessels

ENDEAVOUR

ENDEAVOUR is a industrial vessel. The Coast Guard has recorded 15 inspections since 2004, most recently in December 2025, along with 6 deficiencies and 4 operational controls.

Records from 2004 to 2025. Most recent: operational control imposed, 16 December 2025.

Built
Not recorded
Last inspected
16 December 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9203306 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
—
Maury page id
psix-582

Inspections, by type

…with no type recorded4
Years with a record 6 calendar years (2004–2025)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it2652 - Convention (Subpart B), Net Ton
8376 - Dead Weight, Ton
8840 - Simplified, Gross Ton
8840 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

16 December 2025 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8284057
6 February 2025 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8075857
28 July 2024 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7986357
16 January 2024 PSC B
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 7847026
23 December 2020 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7115600
12 December 2020 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7110662
3 December 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7105611
19 January 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3666026
15 April 2005 NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2334478
10 November 2004 Random ISPS/MTSA/PSC
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2239014
11 October 2004 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2218382
2 July 2004 ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2119004
30 June 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2116792
10 February 2004 Annual Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2004191
4 February 2004 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2003162

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 December 2020 Resolved
11118 - Lifejackets shall be fitted with retro-reflective material distributed as to be useful for search from air and surface craft in all directions. PSCO observed numerous lifejackets with deteriorated retro-reflective tape. 74 SOLAS (14) III/7.2.1 LSA Code 1.2.2.7 Resolution A.658(16) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
Resolution: Received ABS class report confirming retroreflective tape renewed on all lifejackets where retroreflective tape was deteriorated.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 December 2020 Resolved
04108 - Muster lists and emergency instructions shall be exhibited in conspicuous places throughout the ship including crew accommodation spaces. The muster list and emergency instructions were not posted in crew accommodation spaces. 74 SOLAS (14)III/8.3 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
Resolution: Received ABS class report confirming each accomodation space was provided with station bill, as well as fire and emergency instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 12 December 2020 Resolved
11112 - Falls used in launching shall be inspected periodically. According to manufacturer's maintenance recommendations periodic field lubrication may be required to minimize friction and the lubricant should be applied at a point where the rope is being bent. The falls for both lifeboats and the davit launch for the life rafts lacked any visible lubrication. 74 SOLAS (14) III/20.4 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
Resolution: Received ABS class report confirming lubrication had been applied to lifeboat falls and davit launch.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 19 January 2010 Resolved
1720-The Vessel has a damage propeller shaft seal on the starboard side allowing for a potential discharge of oil. Vessel to make repairs to the satisfaction of the classification society and submit class report to the local COTP.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2010
Resolution: Received Classification Report regarding the repairs to the propeller shaft seal on the starboard side.
Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 19 January 2010 Resolved
Vessel is required to comply with LRIT requirements in SOLAS V/19-1, vessel does not have evidence of LRIT compliance via a conformance test report as required per MSC.1/Circ.1307.A. Provide evidence of LRIT compliance prior to next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 December 2020
Resolution: Recieved LRIT conformance test report.
Construction/Loadline › Hull › Hull Plating
Issued 21 July 2004 Resolved
Vessel sustained damage to bow during collision with another vessel in the Port of Fourchon.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 14 April 2005
Resolution: Cleared (MSU Houma/Activity #2218382/21Jul04/Deficiency #01). Was cleared by classification society (ABS) on 02AUG04.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.