VIDA MIA is a 1929 passenger vessel (inspected). The Coast Guard has recorded 41 inspections since 1998, most recently in June 2026, along with 73 deficiencies, 3 operational controls and 2 casualty investigations between 2021 and 2022.

Records from 1998 to 2026. Most recent: inspection, 2 June 2026.

Built
1929
Last inspected
2 June 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI5367
Flag
UNITED STATES
367129360, 367148570, 367707850 (licence lapsed)
Maury page id
psix-58200

Inspections, by type

…with no type recorded5
Years with a record 20 calendar years (1998–2026)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)58.4 ft × 14.6 ft × 7.2 ft
Registered tonnagegross 48 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEPHEN BROTHERS · STOCKTON, CA, UNITED STATES · built 1929
Hull materialWood
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
37 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI5367MMSI 367707850 · expired · compulsorily equipped · granted 24 December 2015, cancelled 7 March 2026
WDD4729MMSI 367148570 · expired · compulsorily equipped · granted 2 November 2006, cancelled 7 January 2017
WDD3357MMSI 367129360 · expired · compulsorily equipped · granted 14 July 2006, cancelled 17 September 2016
WAQ6393MMSI not assigned · expired · compulsorily equipped · granted 7 May 1999, cancelled 18 March 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 41

2 June 2026 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8463700
6 February 2025 COI Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8075929
7 December 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7802236
14 June 2023 Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7681927
20 September 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7549295
6 September 2022 Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 7553183
23 May 2022 Examination of Repairs · Damage Survey · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7457809
22 May 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7466994
22 September 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7317703
7 September 2021 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7306827
7 September 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7308756
23 June 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7233245
5 January 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7119625
14 June 2019 Internal Structural Exam · Drydock Exam · DAPI Audit · Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6734085
11 December 2018 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6581545
5 December 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6318653
25 August 2017 Administrative Inspection · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6254242
27 June 2017 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6190089
4 March 2016 Plan Review "T" Boat · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5827309
22 July 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3542784
28 November 2008 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3363296
26 June 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3248969
25 June 2008 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3211399
28 June 2007 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2976597
12 July 2006 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2695719
11 May 2005 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2355093
14 April 2005 Excursion Permit
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2356415
5 November 2004 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2235491
24 October 2004 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2253097
8 January 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1964629
7 August 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1869337
6 February 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1736184
30 January 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1737611
10 January 2003 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1731424
22 November 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1699675
13 July 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1067462
19 June 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362302
20 April 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1443177
16 November 1999 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365451
18 May 1999 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391047
28 January 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1395222

Deficiency record · 73

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2025 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the lazerette and galley space electric bilge pump. Prove proper operation of both bilge pumps prior to operating. 46 CFR 182.25-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 February 2025 Resolved
A portable hand bilge pump must be capable of pumping water. Portable hand bilge pump was not on-board the vessel. 46 CFR 182.25-10(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 February 2025
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 February 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer’s instructions. Fireboy and portable extinguishers are due for annual servicing. Provide servicing report from Fire Safety Systems. 46CFR181.420(a)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 February 2025
Resolution: Servicing report completed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 February 2025 Resolved
All connections shall be made to the battery terminals with permanent type connectors. Connections on batteries made with non permanent connectors. 46 CFR 183.05-20 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 February 2025
Resolution: Wingnuts removed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 February 2025 Resolved
Vessel shall be equipt with a suitable number of portable battery lights. Replace battery on one portable light. 46 CFR 184.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 February 2025
Resolution: Batteries replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 February 2025 Resolved
Except as noted in 176.114 of this part, each vessel inspected and certificated under the provisions of this subchapter must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. VIDA MIA has lapsed on completing an annual inspection. Vessel is not to operate until a COI is conducted. Please email [email withheld] when ready to schedule the COI. 46 CFR 176.100 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2025
Resolution: COI was conducted and completed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 20 September 2022 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessels mooring cleat hitch on aft port corner is loose. Tighten bolts on deck for cleat hitch. 46 CFR 184.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 4 October 2022
Resolution: Vessel rep tightened cleat on deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2022 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Engine driven raw water pump leaking from the seal on the cooling water line. Repair leaking seal. 46 CFR 182.05-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 4 October 2022
Resolution: Vessel rep repaired leaking seal in pump.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 May 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel has bow and cleat damage. Provide repair proposal for review and approval to the satisfaction of the Marine Inspector. 46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2022
Resolution: Post-repair underway trial completed satisfactory.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 September 2021 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Replace battery to satisfaction of attending Coast Guard Marine Inspector. 46 CFR 180.64
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 24 November 2021
Resolution: Vessel's ordered EPIRB replacement arrived and installed sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 22 September 2021 Resolved
Each officer employed on any vessel subject this subchapter must have his or her license onboard and available for examination at all times when the vessel is operating. Provide properly credentialed mariner medical certificate. 46 CFR 185.402
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 October 2021
Resolved 22 September 2021
Resolution: Operator provided evidence of mariner medical certificate.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 September 2021 Resolved
Vessel is required to ensure the EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Vessel's EPIRB battery was past its expiration date. Vessel is restricted to 3NM from shore until battery is replaced to satisfaction of attending Coast Guard Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2021
Resolved 24 November 2021
Resolution: Vessel provided evidence of newly installed EPIRB onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2021 Resolved
When required by the marine inspector, a portion of the inspection must be conducted while the vessel is underway. Conduct sea trial prior to credit drydock.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 June 2021
Resolution: Vessel completed sucessful sea trial.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 January 2021 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Power strip installed in engine space must be removed. 46CFR183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 22 January 2021
Resolution: Attended vessel to witness corrective repairs. All sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 5 January 2021 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. Crew was unable to demonstrate operation of emergency steering when asked to do so by [name withheld] emergency steering procedures to [email withheld]. 46CFR176.814
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 17 February 2021
Resolution: Vessel provided written instructions and crew training for operation of the emergency steering gear.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 5 January 2021 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's port fuel shutoff valve was not operable. 46CFR182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 17 February 2021
Resolution: Recieved video showing proper operation of the port fuel oil shutoff valve.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 January 2021 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires were found in engine compartment by the battery charger and the port aft engine mount. 46CFR183.200(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 22 January 2021
Resolution: Attended vessel to witness corrective repairs. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 January 2021 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. The batteries located in the port aft side of the engine room do not have a cover. 46CFR183.350(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 22 January 2021
Resolution: Attended vessel to witness corrective repairs. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 January 2021 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Gauge on racor fuel filter is corroded. Replace fuel filter gauge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 22 January 2021
Resolution: Attended vessel to witness corrective repairs. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 January 2021 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Witnessed operation and support of main engine shifter using a rope. Submit repair proposal for installation of permanent fixture of main engine shifter. 46CFR176.800(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 22 January 2021
Resolution: Attended vessel to witness corrective repairs. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2019 Resolved
All vessels should be made available for dry-dock examinations at specified intervals, and provide notification to the Coast Guard as far in advance as possible. Vessel has not completed a credit dry dock exam by required due date as per the Certificate of Inspection. Vessel must schedule and complete a dry-dock exam to the satisfaction of the attending Marine Inspector. Vessel is restricted from carrying passengers until credit dry-dock exam is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2019
Resolved 31 July 2019
Resolution: Vessel completed credit drydock exam this date. Cleared CG-835 requirement and removed operational control. //s// [name withheld], LT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 December 2018 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant; Retroreflective material on ring life buoy on vessel is missing. Install retroreflective material onto ring life buoy.
Action required: 10 - Deficiency Rectified
Resolved 11 December 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 December 2018 Resolved
A port light must have an inside hinged dead cover regardless of whether the port light is or is not capable of being opened; Vessel's port light dead covers are missing dogs. Renew dogs for port lights
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 December 2018
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 December 2017 Resolved
Replace areas of missing insulation between machinery space and accommodation space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 January 2018
Resolved 6 September 2018
Resolution: Verified material met the standard specifications outlined in 46CFR177.410. Inspected machinery room to verify installation of material. All sat.
Documentation › Certificates/Documents › Stability Letter
Issued 25 August 2017 Resolved
Provide and post valid stability letter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 December 2017
Resolved 6 December 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 August 2017 Resolved
Provide and post valid COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2017
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 August 2017 Resolved
Provide stowage markings for all PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 August 2017 Resolved
Provide a first aid kit in compliance with 160.041.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 6 December 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 25 August 2017 Resolved
Replace steering cylinder bypass hose with proper hose for the service iaw 46 CFR 182.620.
Due 15 September 2017
Resolved 6 December 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 25 August 2017 Resolved
prove proper operation of the main engine and generator RPM gauges.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 6 December 2017
Documentation › Markings/Placards › Capacity Marking
Issued 25 August 2017 Resolved
Properly label party deck with passenger limit iaw 46 cfr 185.602.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2017
Documentation › Markings/Placards › Capacity Marking
Issued 25 August 2017 Resolved
Post sign restricting passengers from going forward on bow deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2017
Construction/Loadline › Penetrations › Gasket
Issued 25 August 2017 Resolved
Make lazerette hatch watertight.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 6 December 2017
Stability › Freeing Ports › General
Issued 25 August 2017 Resolved
Provide grates for scuppers iaw 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 6 December 2017
Construction/Loadline › Structures › Deck Plating
Issued 25 August 2017 Resolved
Securely mount forward rails and all deck cleats iaw 46 cfr 184.300.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 6 December 2017
Documentation › Markings/Placards › Warning Signs
Issued 25 August 2017 Resolved
Label forward emergency exit hatch inside and on deck iaw 46 cfr 185.606.
Action required: 705 - Other - as specified
Due 15 September 2017
Resolved 6 December 2017
Navigation › Piloting/Steering › Marine Charts
Issued 23 July 2009 Resolved
Provide up-to-date Marine Charts and Publications applicable to route on COI.
Due 29 July 2009
Resolved 30 July 2009
Resolution: Purchased current Marine Charts and Publications.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 23 July 2009 Resolved
Mark "Adult Life Jackets" and number on aft storage bench.
Due 29 July 2009
Resolved 30 July 2009
Resolution: Properly marked all life jacket storage areas.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 23 July 2009 Resolved
Provide two additional Type I Child Life Jackets.
Due 29 July 2009
Resolved 30 July 2009
Resolution: Purchased two additional child life jackets.
Communications › Radio Communications › EPIRB
Issued 23 July 2009 Resolved
Update hydrostatic release for EPIRB.
Due 29 July 2009
Resolved 30 July 2009
Resolution: Installed new and current hydrostatic release for EPIRB.
Documentation › Markings/Placards › Lifejacket Placard
Issued 23 July 2009 Resolved
Provide Life Jacket Donning Placard
Due 29 July 2009
Resolved 30 July 2009
Resolution: Mounted Life Jacket Donning Placard at all storage areas.
Engineering › Bilge Water Management System › Not Operational
Issued 23 July 2009 Resolved
Repair Foc'sle High Bilge Level Alarm.
Due 29 July 2009
Resolved 30 July 2009
Resolution: Installed new bilge pump and high level alarm.
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2008 Resolved
Grind down and determine extent of damage on all marked areas on external hull. Provide repair proposal for damaged areas.
Action required: 705 - Other - as specified
Resolved 4 December 2008
Resolution: All exterior areas grinded down to good wood and epoxyed. Planks are 1.5 inches thick. Two small areas with worm damage ,approx 3/8" thick damage, were repaired with small dutchman like repairs (Port aft garboard & stbd side 2nd plank up mid-aft).
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2008 Resolved
Make proper repairs to windlass area.
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: Cut down surrounding areas to good wood and sealed with epoxy.
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 November 2008 Resolved
Provide repair proposal and make repairs to shear clamp on port side in forward space.
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: Replaced existing shear clamp and replaced with new.
Construction/Loadline › Hull › Hull Plating
Issued 28 November 2008 Resolved
Determine extent of wood rot/angel hair throughout vessel. make repairs as necessary. See narrative for specific locations.
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Wood rot sanded down and expoyed or wood replaced where necessary and expoyed.
Construction/Loadline › Hull › Transverse Frame
Issued 28 November 2008 Resolved
Make repairs/replace rotten floor frame in master state room.
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: Replaced existing floor frame with new.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 June 2008 Resolved
Company failed to renew annual endorsement for current Certificate of Documentation as required by 46CFR67.163. Provide proof of current certificate of documentation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2008
Resolution: COD renewed, certified fax copy available
Construction/Loadline › Structures › End Bulkhead
Issued 25 June 2008 Resolved
Determine extent of wood rot for entire bulkhead forward of water heater in void space under the galley and submit a repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 10 July 2008
Resolution: Removed all wood with wet rot. Replaced with two 3/4" layers of marine grade plywood mechanically fastened with stainless steel screws. Coated all exposed wood with epoxy.
Construction/Loadline › Structures › End Bulkhead
Issued 25 June 2008 Resolved
Determine extent of wood rot in focsle and submit repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 25 August 2008
Resolution: Received initial repair plan from vessel''s rep. Work will completed during next dry-dock exam. Actual scope of work may change once repairs commence.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 25 June 2008 Resolved
Provide audible alarms for all high level bilge alarms. IAW 46CFR182.530(b)
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 July 2008
Resolved 16 July 2008
Resolution: Tested audible and visual alarms for steering compartment and focsle.
Construction/Loadline › Structures › Scuttle
Issued 25 June 2008 Resolved
Properly label forward emergency escape hatch on both sides with "EMERGENCY EXIT, KEEP CLEAR." IAW 46CFR185.606
Action required: 705 - Other - as specified
Due 9 July 2008
Resolved 10 July 2008
Personnel › Training › First Aid/CPR
Issued 12 July 2006 Resolved
Provide red cross/first aid cards for 50% of crew.
Due 12 August 2006
Resolved 11 August 2006
Documentation › Logs/Records › Drug Test Records
Issued 12 July 2006 Resolved
Provide proof of MIS submission to Commandant IAW 46 CFR 15.
Due 12 August 2006
Resolved 11 August 2006
Documentation › Logs/Records › Drug Test Records
Issued 12 July 2006 Resolved
Provide list of DAPI covered employees IAW 46 CFR 15.
Due 12 August 2006
Resolved 11 August 2006
Documentation › Logs/Records › Drug Test Records
Issued 12 July 2006 Resolved
Provide all DAPI test results for CY06 IAW 46 CFR 15.
Due 12 August 2006
Resolved 11 August 2006
Documentation › Certificates/Documents › FCC SSL
Issued 12 July 2006 Resolved
Provide valid FCC Station License.
Due 12 August 2006
Resolved 11 August 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 12 July 2006 Resolved
Provide current copies of the following: US Coast Pilot, USCG Light List, Tide/Current tables IAW 46 CFR 184.420.
Due 12 August 2006
Resolved 11 August 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 July 2006 Resolved
Post original COI at operating station IAW 46 CFR 176.107.
Due 12 August 2006
Resolved 11 August 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 January 2004 Resolved
Repair grablines and straps on both required lifebouys. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 16 January 2004
Resolved 5 November 2004
Communications › Radio Communications
Issued 7 August 2003 Resolved
Replace expired hydrostatic release on EPIRB IAW 46 CFR 180.64 LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 18 August 2003
Resolved 12 August 2003
Lifesaving › Inflatable Liferafts
Issued 6 February 2003 Resolved
Service inflatable liferaft.
Due 7 March 2003
Resolved 7 August 2003
Communications › Radio Communications
Issued 6 February 2003 Resolved
Replace antenna on EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2003
Accommodation/Occupational Safety
Issued 6 February 2003 Resolved
Remove portable gasoline tank from the enclosed forward deck locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2003
Lifesaving › Lifebuoys
Issued 6 February 2003 Resolved
Provide quick release clip for float light.
Due 7 March 2003
Resolved 7 August 2003
Fire Fighting
Issued 6 February 2003 Resolved
Provide three fire buckets.
Due 7 March 2003
Resolved 7 August 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 6 February 2003 Resolved
Provide one additional B-II fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2003
Engineering
Issued 6 February 2003 Resolved
Prove vent for sewage tank.
Due 7 March 2003
Resolved 7 August 2003
Electrical › Electrical Distribution System (service)
Issued 10 January 2003 Resolved
Provide repair proposal and repair all electrical damage, caused by fire. Informed the captain that that all single strand A/C wire must be replaced with cable and all terminal blocks, splices, and connections must be placed in enclosures. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 30 January 2003
Construction/Loadline › Hull › Stringer
Issued 22 November 2002 Resolved
Repair rotted chine clamp on port side in the galley bilge.
Action required: 705 - Other - as specified
Resolved 4 December 2002
Construction/Loadline › Hull
Issued 22 November 2002 Resolved
Crop and renew rotted shaft log, keelson, and transverse frames aft of shaft stuffing box.
Action required: 705 - Other - as specified
Resolved 4 December 2002
Lifesaving
Issued 19 June 2001 Resolved
Provide an additional 3 adult life jackets prior to carrying more than 49 persons on board vessel.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 19 June 2001 Resolved
Repair wood rot at transom beam and center stern frame.
Condition: Unknown
Due 20 July 2001
Resolved 11 December 2002

Casualty record · 2

7 September 2021Routine · role: Involved in a Marine Casualty · activity 7308756
22 May 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7466994
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.