MAURY USCG vessel records
← All vessels

SEAWAYS GOLDMAR

SEAWAYS GOLDMAR is a 2002 tank ship. The Coast Guard has recorded 10 inspections since 2016, most recently in May 2021, along with 2 deficiencies and 2 operational controls.

Records from 2016 to 2021. Most recent: operational control imposed, 31 May 2021.

Built
2002
Last inspected
31 May 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 May 2021
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9239628
582286
Flag
MARSHALL ISLANDS
Maury page id
psix-582286

Documentation record

Tonnage as PSIX records it40343 - Convention (Subpart B), Gross Ton
20334 - Convention (Subpart B), Net Ton
69684 - Dead Weight, Metric Ton
82850 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

31 May 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7211233
31 May 2021 Type not recorded
No type recorded · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 7213420
6 December 2020 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7107018
19 January 2020 Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6892372
19 January 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7065092
18 March 2019 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6637358
27 February 2018 Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6358829
23 February 2017 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6088450
25 August 2016 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5983400
25 April 2016 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5862354

Deficiency record · 2

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 January 2020 Resolved
Main and auxilliary machinery essentail for the propulsio, control and safety of the ship shall be provided with effective means for its operation and control. Vessel expericenced a black out along with M/E governor alarm. M/E RPM's can not be adjusted from bridge or ECR. Local ENG control only.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 January 2020
Resolved 21 January 2020
Resolution: Received satisfactory class report.
Engineering › Gas Turbine (auxiliary) › Enclosure
Issued 3 May 2016 Resolved
The inert gas systems refered to in SOLAS Ch. II-2 shall be designed, contructed and tested tothe satisfaction of the Administration. The Inert Gas Generator housing is stainless steel with multiple unauthoriaed weld repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 June 2016
Resolved 25 August 2016
Resolution: See attached Class Report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.