Records from 2016 to 2026. Most recent: inspection, 26 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 14.0 ft × 6.7 ft
Registered tonnagegross 28 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKLEY'S MARINA INC · CAMBRIDGE, MD, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portCHESAPEAKE BEACH, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page
19 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
26 June 2026
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8416361
15 June 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8405196
14 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8350041
1 July 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8172430
3 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7889341
11 March 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7877379
25 April 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7675612
12 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7430640
6 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7425931
13 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7176824
10 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6973300
17 April 2020
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6940333
26 March 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6931903
11 February 2019
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6623710
10 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6394196
29 March 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6384049
11 April 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6132256
14 April 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5856285
10 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5830984
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 June 2026
Resolved
01305 - The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months. The vessel had not drill logs for the 2025 season.
46 CFR 185.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2026
Resolution: Vessel owner provided drill logs.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2026
Resolved
11117 - Each ring life buoy must be marked with Type II retroreflective material. There was no retroreflective material on the ring buoy.
46 CFR 185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 June 2026
Resolution: Photographic evidence was provided showing retro on the ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 June 2026
Resolved
11117 - A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. The floating waterlight needs new batteries. The vessel is restricted to daylight operations only.
46 CFR 180.70(d)
Action required: 705 - Other - as specified
Resolved 26 June 2026
Resolution: Vessel owner provided a video of the operable float light.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2021
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Life float life line tabs degraded. 46 CFR 180.175
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 2 June 2021
Resolution: O/Op purchased and installed a new life float.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 April 2021
Resolved
Each flare carried to meet this section must be stowed in a portable watertight container marked as required by §185.614 of this chapter, carried at the operating station. Flares were not in a watertight container. 46 CFR 180.68(e)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 7 June 2021
Resolution: New water tight container purchased and properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 April 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and publications.
Vessel's Coast Pilot and charts were out of date. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2021
Resolved 7 June 2021
Resolution: New pubs purchased.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 April 2021
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel had a SA (Ship Recreational) Station License vice SB (Ship Compulsory Equipped). 46 CFR 184.502
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 May 2021
Resolved 12 April 2022
Resolution: Confirmed correct FCC Station license on board.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 June 2020
Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. Stenciling of capacity was faded.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Lettering on life float was restenciled.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 10 June 2020
Resolved
If the buoyancy tubes are not vivid reddish orange, vivid yellow, or a fluorescent color of a similar hue, panels of such hue must be secured to the buoyancy chambers so that a minimum of 1 m2 (11 ft2) is visible from above the apparatus when it is floating either side up. Life float was a green color on top.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2020
Resolution: Life float was properly cleaned. Overspray was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2020
Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Fuel filter for main engine has a hole in it.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 July 2020
Resolution: A new flame sheild was put on.