Records from 2004 to 2025. Most recent: inspection, 15 October 2025.
Inspection history · 30
15 October 2025
Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8271158
19 February 2025
Examination of Repairs · Deficiency Check · Annual Inspection · Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8084722
24 July 2024
Drydock Exam · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7965631
8 September 2023
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7734778
31 August 2023
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7773501
22 May 2023
Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7694115
3 May 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7686917
24 February 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7641543
8 February 2023
Administrative Inspection · Damage Survey · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7634591
8 February 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7636229
18 July 2022
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7506044
27 January 2022
Drydock Exam · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7386196
1 November 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7342953
31 October 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7343939
10 March 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7154068
23 September 2020
Hull Examination · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7062724
1 June 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6965090
17 April 2020
Administrative Inspection
Administrative · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6940383
18 February 2020
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6910447
10 December 2019
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6875914
26 February 2019
Annual Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6632669
1 September 2018
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6557789
26 May 2018
Damage Survey
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6435542
14 December 2017
COI Inspection · DAPI Audit
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6323132
13 October 2017
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288526
19 September 2017
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6288475
19 April 2017
Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6128234
7 March 2017
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6097165
7 October 2016
Hull Examination · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6018145
9 March 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5829787
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 February 2025
Resolved
The FCC Bridge-to-Bridge Safety Radio Act applies to every power-driven vessel of 20 meters or over in length while navigating. The vessel did not have an FCC Bridge-to-Bridge Safety Certificate. 47 CFR 80.1001(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: Certificate was issued by a local technician.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2025
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. Dead end wires were found under the
operating station. 46 CFR 183.200(b). 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: Dead end wires have been secured.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 February 2025
Resolved
A vessel not required to have a power driven fire pump
must have at least three 2.5 gallon buckets. The vessel
had three 5 gallon buckets.46 CFR 181.610. 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: Buckets were fixed at 2.5 gallons.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 February 2025
Resolved
Control of the main steering gear, including control of
any necessary associated devices (motor, pump, valve,
etc.), must be provided from the operating station. A
hydraulic leak from the steering apparatus was found under the helm at the operating station. 46 CFR 182.610(b) 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: Leak was corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2025
Resolved
At least one ring life buoy must be fitted with a lifeline. The ring buoy lifeline needs to be replaced. 46 CFR 180.70(c), 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: Lifeline has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 February 2025
Resolved
Each buoyant apparatus must be fitted with a lifeline, pendants, two paddles, a painter and a light. Life float life line was found wasted due to UV light deterioration. 46 CFR 180.150, code 16.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: Line was replaced and paddles were also replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 February 2025
Resolved
The lights prescribed in these Rules shall be visible at the following minimum ranges: in a vessel of 12 meters or more in length but less than 50 meters in length: a stern light, 2 miles. The stern light was not working and the diffuser has sun damage losing transparency. 33 CFR 83.22(b)(iii), 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: A new stern light was mounted.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 19 February 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines. The
fuel shut off valve on the starboard side was installed incorrectly preventing from being closed from outside of the space with the actuator cable, but closes manually from inside of the compartment. 46 CFR 182.455(b)(4), code 16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 March 2025
Resolved 10 March 2025
Resolution: Valved was reinstalled correctly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2025
Resolved
Nonmetallic flexible hoses conforming to SAE J1942 may be used without length limitations provided they do not penetrate watertight bulkheads and decks. Flexible fuel hoses were found penetrating watertight bulkheads both port and starboard side hulls. 46 CFR 46.60-25, 50C.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2025
Resolved 16 April 2025
Resolution: New approved fittings have been installed in the watertight bulkhead.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 31 August 2023
Resolved
Each survival craft required on a vessel by this part must be approved under approval series 160.027 or other standard specified by the Commandant. Inspector observed both life float's grab line were wasted, reflective tape was wasted, and cracks were observed on the foam part of the life float. Replace grab line, replace reflective tape, repair life float with approved repair kit.
46 CFR 180.200
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 November 2023
Resolution: Life float reflective tape and lanyard replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 February 2023
Resolved
On a ferry vessel of not more than 65 feet must have a self priming, power driving fire pump installed with a minimum capacity must be 38 liters (10 gallons) per minute. The vessel was operating as ferry vessel without a power driver fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2023
Resolved 14 February 2023
Resolution: Vessel representative indicated in writing the vessel would not be used for ferry service without a fire pump. Only vessels in their fleet with a fire pump would be utilized.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 February 2023
Resolved
Vessel reported operating above the passanger limit listed on the COI.
Action required: 10 - Deficiency Rectified
Resolved 9 February 2023
Resolution: SSJ I/O's issued LOW to the vessel captain.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 27 July 2022
Resolved
The owner of a vessel must conduct a stability test of the vessel and calculate its vertical and longitudinal centers of gravity and its lightweight displacement. The vessel had been re-powered with new engines and transmissions. No weight movements and vertical center of gravity calculations of the changes were submitted for review to the Marine Safety Center.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 August 2022
Resolved 3 October 2022
Resolution: H1-2203201 correspondence from MSC. Lightship displacement was not exceeded. Vessel's current stability will remain valid.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 July 2022
Resolved
No vessel subject to inspection under 46 U.S.C. 3301 will be navigated unless it is under the direction and control of an individual who holds an appropriate license or officer endorsement on his or her MMC. The master did not have their medical certificate onboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2022
Resolved 25 August 2022
Resolution: Master provided evidence of new updated medical certificate. Pic attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 July 2022
Resolved
A hatch exposed to the weather must be watertight, have securing devices and be attached by hinges, captive chains or other devices or substantial strength to prevent its loss. (a) The port aft engine room deck hatch leaked during a hose test. (b) The port and starboard deck hatches did not have have securing devices and the hatches did not have a captive device to prevent their loss. (c) The starboard bunker void hatch leaked during a hose test.. 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2022
Resolved 22 July 2022
Resolution: Conducted hose test all hatched tested satisfactory accept the port forward void deck hatch - cleared this requirements and issued deficiency number 02a for the Port FWD void hatch. Vessel rep to pull up deck hatch frame and reseal.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 18 July 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Both the port and starboard hull fuel tank vents flame screens were fabricated in such a way that gaps existed in the 30 x 30 mesh which would allow a flame to enter the fuel tanks.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2022
Resolved 22 July 2022
Resolution: Clean 30 x 30 mesh flame screens were installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2022
Resolved
Portable fire extinguisher must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge Marine Inspection. The portable fire extinguisher located next to the helm had recently been renewed, the bracket is too small for the fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2022
Resolved 22 July 2022
Resolution: The protable fire extinguisher was installed on the starboard side of the fixed seat at the operating station
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 July 2022
Resolved
Provisions must be made to prevent or mitigate the effect of galvanic corrosion due to the relative solution potentials of copper, aluminum, and alloys of copper and aluminum, which are used in conjunction with each other, steel, or other metals and their alloys. Found that the vessel's electrical bonding systems in both the port and starboard hulls had not been maintained in accordance with the vessel's electrical plans, including the electrical bonding of all sea valves.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2022
Resolved 2 November 2022
Resolution: Electrical bonding added for every each sea valve.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 18 July 2022
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. The markings required may be made by the use of any means and materials which result in durable markings, must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. Found that the vessel's name was not permanently affixed on the stern.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 22 July 2022
Resolution: Vessel name placed on the stern of the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 July 2022
Resolved
The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84.13(c). The vessel only had one ball day shape onboard; missing an additional ball and diamond day shapes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 2 November 2022
Resolution: Additional ball and 2 diamond shapes added to vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Both main propulsion engines were missing guards to cover the alternators and associated drive belts.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 1 May 2023
Resolution: A special consideration request was approved. See special notes for requirements.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 18 July 2022
Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. The posted emergency instruction did not address crew-members being directed by the master prior to activating the fixed fire fighting systems for port and starboard engine rooms.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 22 July 2022
Resolution: Updated emergency instruction delineating induvial deck hands responsibilities for engine room fires and when to activate fixed firefighting at the direction of the master.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2022
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part. Found that the drills/training were not conducted and logged prior to prior to the commencement of the renewal of the Certificate of Inspection.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 18 July 2022
Resolved 18 July 2022
Resolution: Master log drill after fire/manoverboard drills were witness by the attending marine inspector. Crew appears to be trained in their duties.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 18 July 2022
Resolved
A hatch exposed to the weather must be watertight, have securing devices and be attached by hinges, captive chains or other devices or substantial strength to prevent its loss. The port deck hatches frame, on the inboard side, was found to be leaking during the hose test. 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2022
Resolved 22 July 2022
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 18 July 2022
Resolved
Machinery space boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009. The current condition of the existing insulation does not sufficiently provide protection to several specified areas on both the Port and Starboard engine compartments. Any areas not covered with insulation are required to be covered. 46 CFR 177.410(c)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 July 2022
Resolved 4 August 2022
Resolution: Cleared SFP repairs for the Port FWD, STBD FWD and STBD Aft overheads by the attached videos provided by vessel rep [name withheld] repairs to the port aft engine room was cleared by visual inspection the the attending Master Marine Inspector on 7/22/22.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. When vessel was returned to the water following dry dock, a cut in the port side shaft tube was discovered allowing a steady rate of water into the vessel. Submit repair proposal to attending marine inspector prior to commencing work.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: repaired and tested underway with no signs of leaks.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 27 January 2022
Resolved
Overhead Insulation/structural fire protection in machinery boundry void#4 Port and STBD, saturated and wasted from water exposure. Requires replacement.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2022
Resolved 22 July 2022
Resolution: Reissued under Activity 7506044
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 January 2022
Resolved
Remove and seal through-hull penetrations not in use (hatch coaming drains, PVC plugs at side shell, etc.)
Action required: 705 - Other - as specified
Due 27 January 2022
Resolved 1 March 2022
Resolution: Holes were properly plugged.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 January 2022
Resolved
Replace electrical bus bar that is showing signs of corrosion and discoloration.
Action required: 705 - Other - as specified
Due 27 January 2022
Resolved 4 May 2022
Resolution: Electrical bus bars replaced throughout
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 January 2022
Resolved
Starboard Side Fuel Tanks Space:
Repair fractured frames (inboard side) supporting diesel fuel tanks.
Action required: 705 - Other - as specified
Due 27 January 2022
Resolved 4 May 2022
Resolution: Fractured diesel tank support frames repaired
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 March 2021
Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. The insulation located in the port aft engine room compartment above the engine exhaust stack is wet and water logged.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect the vessel from electrical hazards. A receptacle in the port side engine compartment by the access ladder was loose and unsecured.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 March 2021
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with VHF-DSC to include GPS. The vessels VHF radio did not have GPS.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 March 2021
Resolved
Electrical equipment on a vessel must be installed and maintained to protect the vessel from electrical hazards. A dead end cable was found at the operating station above the helm.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 23 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 June 2020
Resolved
A vessel must have a float-free link of proper strength
for the size of the life float. The float-free link was
not labeled. Vessel is restricted to 3 nautical miles
until specification of link is demonstrated.
Action required: 705 - Other - as specified
Due 1 July 2020
Resolved 11 June 2020
Resolution: vessel rep submitted proof of repairs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2020
Resolved
A vessel must have a valid FCC safety radiotelephony
certificate. Certificate is invalid.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 11 June 2020
Resolution: vessel rep submitted proof of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2020
Resolved
Machinery spaces must be lined with insulation. Overhead
insulation was wasted in certain areas.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 11 June 2020
Resolution: vessel rep submitted proof of repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 1 June 2020
Resolved
Each paddle must be lashed to the life float. Life float
paddles were found unsecured.
Action required: 10 - Deficiency Rectified
Resolved 22 June 2020
Resolution: Paddles were lashed prior.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2020
Resolved
First aid kits must carry contents in 46 CFR 160.041.
First aid kit was found to be missing a tourniquet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2020
Resolved 11 June 2020
Resolution: vessel rep submitted proof of repairs.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 26 February 2019
Resolved
Overhead insulation above both main propulsion engines are wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2019
Resolved 19 January 2021
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 14 December 2017
Resolved
Radio is not programmed with the vessel's MMSI number.
Condition: Invalid
Due 28 December 2017
Resolved 17 December 2017
Resolution: vessel operator entered the MMSI number.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 7 March 2017
Resolved
Prove proper operation of (RPM) gauge of port engine at the operating station.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 15 March 2017
Lifesaving › Lifefloat › Painter
Issued 7 March 2017
Resolved
Life floats must be individually attached to painter which is attatched to the float free link which is attatched to the vessel
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Lifesaving › Lifefloat › Painter
Issued 7 March 2017
Resolved
Life Float must have painter attatched by encircling the body of the life float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Electrical › Electric Supply System (service) › Cable
Issued 7 March 2017
Resolved
Remove dead ended wires in Port engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 15 March 2017
Electrical › Electric Supply System (service) › Cable
Issued 7 March 2017
Resolved
Connect grounding cable in the STBD aft compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 7 March 2017
Resolved
Remote fuel shutoff stations must be clearly marked in letters at least one inch high. None labeled. Ventilation closures must be labeled as well.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Engineering › Fuel Oil Service System › Valve
Issued 7 March 2017
Resolved
Replace the fuel shutoff cable on the port side and prove proper operation from outside the space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2017
Resolved 8 March 2017
Electrical › Electric Supply System (service) › Cable
Issued 7 March 2017
Resolved
Properly support cable in Port Engine Room with metal supports not more than 24 inches apart. Limit plastic wire ties to bundling.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Electrical › Electric Supply System (service) › Cable
Issued 7 March 2017
Resolved
Replace wire on the port engine that has multiple splices.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 7 March 2017
Resolved
Secure water pump in Port Aft Engine room properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 8 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 7 March 2017
Resolved
Prove proper operation of lights in port engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 15 March 2017
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 7 March 2017
Resolved
An adult life jacket must be provided for each person onboard.
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 7 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 7 March 2017
Resolved
The stern light must be located centerline of the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2017
Resolved 3 April 2017
Resolution: The sternlight has been moved to aprox 6 STBD of centerline