MAURY USCG vessel records Sign in
← All vessels

MAERSK RHODE ISLAND

MAERSK RHODE ISLAND is a 2001 tank ship. The Coast Guard has recorded 45 inspections since 2002, most recently in April 2017, along with 39 deficiencies and 5 casualty investigations between 2004 and 2008.

Records from 2002 to 2017. Most recent: inspection, 20 April 2017.

Built
2001
Last inspected
20 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9236975 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
583859
Flag
MARSHALL ISLANDS
369182000 (licence lapsed)
Maury page id
psix-583859

Inspections, by type

…with no type recorded12
Years with a record 11 calendar years (2002–2017)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it22184 - Convention (Subpart B), Gross Ton
9438 - Convention (Subpart B), Net Ton
34999 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WADXMMSI 369182000 · expired · compulsorily equipped · granted 20 August 2002, cancelled 20 October 2012 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 45

20 April 2017 COI Inspection
Physical examination · Activities Europe · Activity 6128835
25 June 2012 MARPOL Annex II Examination · COI Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · DAPI Audit
Physical examination · Activities Europe · Activity 4344657
15 June 2012 Drydock Exam · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal
Physical examination · Activities Europe · Activity 4320367
9 September 2011 Annual Inspection
Physical examination · Activities Europe · Activity 4039092
18 January 2011 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 3927942
30 July 2009 Ballast Water Examination · Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3548106
15 January 2009 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3489515
6 January 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3389465
10 October 2008 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 3444603
5 August 2008 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3305429
31 July 2008 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3290282
29 July 2008 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3282621
21 July 2008 Ballast Water Examination · Annual Inspection
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3275078
16 April 2008 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3185060
24 March 2008 Damage Survey · Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3170050
12 March 2008 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 3162722
15 September 2007 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3059190
23 July 2007 Hull Examination · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 3004418
16 October 2006 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2801716
3 October 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2792666
18 September 2006 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2781427
12 September 2006 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2776488
11 September 2006 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2775985
21 July 2006 Damage Survey
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2721477
21 July 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2722388
6 March 2006 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2599677
7 December 2005 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2565047
3 June 2005 Type not recorded
No type recorded · Activities Europe · Activity 2383410
25 April 2005 Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 2332713
21 February 2005 Type not recorded
No type recorded · Activities Europe · Activity 2313342
30 November 2004 Damage Survey
Physical examination · Activities Europe · Activity 2250172
29 November 2004 Type not recorded
No type recorded · Activities Europe · Activity 2253889
2 November 2004 Deficiency Check · Periodic Inspection
Physical examination · Activities Europe · Activity 2163788
8 September 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2190431
4 June 2004 MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2049516
9 January 2004 Type not recorded
No type recorded · Activities Europe · Activity 1980172
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979873
3 October 2003 Deficiency Check
Physical examination · Activities Europe · Activity 1938734
4 September 2003 Annual Inspection
Physical examination · Activities Europe · Activity 1889441
23 August 2003 Type not recorded
No type recorded · Activities Europe · Activity 1902269
8 May 2003 Type not recorded
No type recorded · Activities Europe · Activity 1798742
13 April 2003 Administrative Inspection
Administrative · Activities Europe · Activity 1766836
15 March 2003 Administrative Inspection
Administrative · Activities Europe · Activity 1757623
2 December 2002 Deficiency Check
Physical examination · Activities Europe · Activity 1719090
6 September 2002 MARPOL Annex II Examination · MARPOL Annex V Examination · Initial Certification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 1680863

Deficiency record · 39

Lifesaving › Lifeboat › Propulsion Transmission
Issued 25 June 2012 Resolved
prove proper operation of the deluge system and ahead and astern propulsion.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2012
Resolution: received email from the master with photographic evidence, stating the lifeboat was operational.
Deck/Cargo › Holds/Tanks › Ullage
Issued 4 August 2009 Resolved
Make permanent repairs to the closure on starboard Slop Tank ullage opening.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 September 2009
Resolved 25 August 2009
Resolution: Ullage opening securing mechanism has been repaired.
Deck/Cargo › Ballast › Pumps
Issued 4 August 2009 Resolved
Make permanent repairs to ballast pump priming vent lines located in the ballast pump room.
Action required: 705 - Other - as specified
Due 30 September 2009
Resolved 20 October 2009
Resolution: Ballast pump vent lines have been renewed.
Lifesaving › Launching Appliances › Release Mechanism
Issued 30 July 2009 Resolved
Conduct 1.1 release test of the freefall lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 July 2009
Resolved 4 August 2009
Resolution: Witnessed test of release mechanism at 1.1 times "B" weight.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 3 December 2008 Resolved
VRP #02474 must be amended per Reg 33 CFR 155.1065(f) to submit an equipment list for GRSL oil spill removal organization, or pursue alternate planning criteria for the Guam Captain of the Port zone.
Due 3 January 2009
Resolved 15 May 2009
Resolution: Deficiency cleared, plan expires 05/16/2012.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 21 July 2008 Resolved
Vessel did not submit Ballast report.
Action required: 15 - Rectify deficiencies by next port
Resolved 29 July 2008
Resolution: Vessels master sent e-mail with attached copy of ballast report.
Construction/Loadline › Hull › Bottom Plating
Issued 24 March 2008 Resolved
Echo depth sounder space has hull damage between frames 212-220, two minor weld fractures were discovered and approx 1" hull protrusion into the space from an earlier grounding. Lat's and longs are not tripped or fractured, minor bend in the long with no strength loss in the frame.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 April 2008
Resolution: Received copy of Class report from Surveyor Hong, Dae Woong signing off on the slight bottom damage to the forward transducer space. Case closed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 March 2008 Resolved
Make proper repairs to onboard Oil Discharge Monitoring Equipment no later than 12 April 2008 to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 April 2008
Resolved 24 March 2008
Resolution: Inspected the vessels ODME, tested unit in two manual modes with sat results, tested unit at the photo eye station with sat results.
Lifesaving › Launching Appliances › Winch
Issued 23 July 2007 Resolved
Make effective repairs to replace temporary replacement on lifeboat recovery winch system to the satisfaction of the attending CG Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 August 2007
Resolved 24 March 2008
Resolution: Inspected documents from Class stating winch motor was tested and repaired as of 26AUG07.
Communications › Radio Communications › Satellite Communications Capability
Issued 12 September 2006 Resolved
Make proper repair to the inoperative INMARSAT (#2 of 2), radio. SOLAS 74 Amend Chapter IV 10-1.1 and 15-7.
Action required: 705 - Other - as specified
Due 12 October 2006
Resolved 14 October 2006
Construction/Loadline › Hull › Hull Plating
Issued 21 July 2006 Resolved
Make permanent repairs to hull plating IWO #5 port WBT, frames 84 to 92. Complete repairs to satisfaction of attending USCG Marine Inspector and vessel's classification society.
Action required: 705 - Other - as specified
Due 7 September 2007
Resolved 25 July 2007
Resolution: Completed sat repairs on hull plating in #5 port WBTfr 84-92.
Construction/Loadline › Hull › Keel
Issued 21 July 2006 Resolved
Make permanent repairs to bilge keel IWO #5 port WBT frames 84 to 92. repairs to be made to the satisfaction of attending USCG Marine Inspector and vessel’s classification society.
Action required: 705 - Other - as specified
Due 7 September 2007
Resolved 25 July 2007
Resolution: Completed sat repairs to bilge keel #5 port fr 84-92.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 24 February 2006 Resolved
Tank Radar System has bad PCB Card
Action required: 705 - Other - as specified
Due 27 February 2006
Resolved 27 February 2006
Resolution: The Auxitrol CPU card was reset and the software was downloaded. The tank controller was reset. The communication and system was tested. All sat.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 24 February 2006 Resolved
The 98% H/H level alarm sensors on the COT 3 PS and Slop PS were found to be defective.
Action required: 705 - Other - as specified
Due 27 February 2006
Resolved 27 February 2006
Resolution: The PCB and the probe was exchange and the system was tested. All sat.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 24 February 2006 Resolved
The 95% High level alarm in the COT 3 PS was found to be defective.
Action required: 705 - Other - as specified
Due 27 February 2006
Resolved 27 February 2006
Resolution: The 95% High level alarm in the COT 3 PS had an error in the software. Error was corrected in the software program. All sat.
Personnel › Manning/Qualifications › Person in Charge (PIC) of Transfer
Issued 25 April 2005 Resolved
Vessel manning during Cargo operations needs to be increased by another Mate. To assist with the safe movement of Cargo.
Due 26 April 2005
Resolved 26 April 2005
Resolution: Captain and Port WEngineer advised of concern.
Fire Fighting › Structural Fire Protection - General
Issued 4 September 2003 Resolved
Restore insulation in the IGS room, blower room, and CO2 room to A60 as original. Insulation disturbed during CO2 installation. LEGACY COMPONENT DESC: Deckhouse Construction
Action required: 705 - Other - as specified
Due 24 October 2003
Resolved 3 October 2003
Electrical › Lighting (emergency)
Issued 4 September 2003 Resolved
Lifeboat/life raft embarkation lights frozen. Free up lifeboat/liferaft embarkation lights LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 25 October 2003
Operations/Management › Drills/Instruction
Issued 4 September 2003 Resolved
Provide instructions/directions to the local release for the IGS room/blower room CO2 system at the remote station in accordance with 46CFR34.15-10.
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 10 October 2003
Resolution: Received e mail picture of required instructions. Cleared requirement.
Operations/Management › FireFighting
Issued 4 September 2003 Resolved
Conspicuously mark all CO2 discharge alarms adjacent alarm "WHEN ALARM SOUNDS VACTE AT ONCE CARBON DIOXIDE BEING RELEASED". IAW 46CFR35.40-7 LEGACY COMPONENT DESC: CO2 evacuation sign
Action required: 705 - Other - as specified
Due 24 September 2003
Resolved 3 October 2003
Fire Fighting › Firemans Outfit
Issued 4 September 2003 Resolved
Provide proper bootsfor fireman's outfit vice fisherman's boot. LEGACY COMPONENT DESC: Boots
Action required: 705 - Other - as specified
Due 14 September 2003
Resolved 3 October 2003
Fire Fighting › Firemans Outfit
Issued 4 September 2003 Resolved
Provide helmets for all fireman's outfits. LEGACY COMPONENT DESC: Helmet
Action required: 705 - Other - as specified
Due 14 October 2003
Resolved 3 October 2003
Lifesaving › Inflatable Liferafts
Issued 6 September 2002 Resolved
Post liferaft launching instructions, stbd side. LEGACY COMPONENT DESC: Markings
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL SENT ON 02DEC02 (SCANNED INTO MISLE DOCUMENTS)
Lifesaving › Embarkation Appliances/Stations
Issued 6 September 2002 Resolved
Label all muster stations. LEGACY COMPONENT DESC: Designated Location
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Lifesaving › Buoyant Smoke Signals
Issued 6 September 2002 Resolved
Splice lanyard to Bridge smokes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Documentation › Safety/Response Plans/Programs
Issued 6 September 2002 Resolved
Emergency ventilation shutdown marked on fire control plan not found in IGG space. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Electrical › Electrical Distribution System (service)
Issued 6 September 2002 Resolved
Remove dead ended wiring in IGG space. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Documentation › Safety/Response Plans/Programs
Issued 6 September 2002 Resolved
General alarm located in the upper deck A/C space not listed on fire control plan. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Fire Fighting › Fire Hydrants
Issued 6 September 2002 Resolved
Label all fire stations. LEGACY COMPONENT DESC: Number
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Fire Fighting › Fire Hoses
Issued 6 September 2002 Resolved
Provide fire hose station to forward rope store hydrant. LEGACY COMPONENT DESC: Condition
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Fire Fighting › Means of Escape
Issued 6 September 2002 Resolved
Clear engineroom emergency escape trunk of debris and prove operation of all lights. LEGACY COMPONENT DESC: Enclosed Stairway
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Engineering › Sea-water System (primary cooling)
Issued 6 September 2002 Resolved
Label overboard penetration, stbd A/C space. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Fire Fighting › Means of Escape
Issued 6 September 2002 Resolved
Install IMO escape signage, lower level engineroom. LEGACY COMPONENT DESC: Escape Route Signs
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 6 September 2002 Resolved
Properly label all deck piping valves. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 6 September 2002 Resolved
Pemanently label all cargo piping spool pieces as to location. LEGACY COMPONENT DESC: Adapters
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 September 2002 Resolved
Provide medical first aid kit, required medical supplies and equipment for hospital space. LEGACY COMPONENT DESC: Hospital Space
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Lifesaving › Buoyant Apparatus
Issued 6 September 2002 Resolved
Attachments to ring buoys to be spliced around girth of device.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Documentation › Certificates/Documents
Issued 6 September 2002 Resolved
Provide valid FCC radiotelephone certificate by first U.S. port. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 2 December 2002
Resolution: CLEARED VIA E-MAIL & FAX SENT ON 01DEC02 (SCANNED INTO MISLE DOCUMENTS)
Fire Fighting › Fire Hoses
Issued 6 September 2002 Resolved
Provide fire hose station to forward rope store hydrant. LEGACY COMPONENT DESC: Condition
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 December 2002
Resolved 20 June 2003

Casualty record · 5

9 January 2004Routine · role: Involved in a Marine Casualty · activity 1980172
21 February 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2313342
3 June 2005Routine · role: Involved in a Marine Casualty · activity 2383410
21 July 2006Routine · role: Involved in a Marine Casualty · activity 2722388
10 October 2008Routine · role: Involved in a Marine Casualty · activity 3444603
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.