W. O. DECKER

W. O. DECKER is a 1930 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2001, most recently in June 2026, along with 21 deficiencies.

Records from 2001 to 2026. Most recent: inspection, 22 June 2026.

Built
1930
Last inspected
22 June 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ2900
Flag
UNITED STATES
367117550
Maury page id
psix-58452

Inspections, by type

…with no type recorded1
Years with a record 15 calendar years (2001–2026)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)47.8 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · LONG ISLAND CITY, NY, UNITED STATES · built 1930
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ2900MMSI 367117550 · active · voluntarily equipped · granted 21 November 2016, expires 21 November 2026
WDD2612MMSI 367117550 · expired · compulsorily equipped · granted 26 May 2006, cancelled 30 July 2016
WAB4313MMSI not assigned · expired · compulsorily equipped · granted 6 April 1994, cancelled 22 August 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 22

22 June 2026 COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8410093
27 September 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8242350
27 August 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8218502
5 May 2025 Construction Oversight
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8128869
11 September 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8000345
30 October 2023 Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7806853
23 May 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7694787
14 September 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7562669
26 August 2022 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7543921
28 June 2021 Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7237856
26 October 2020 Hull Examination · COI Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7082823
19 October 2017 Simplified Stability Test · Drydock Exam · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339974
3 July 2012 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4366156
10 August 2011 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4110670
9 July 2009 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3535277
10 September 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3321747
5 August 2008 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3289486
22 May 2008 Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3211112
28 March 2007 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2896563
24 October 2006 Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2807193
11 May 2006 Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 2646526
24 October 2001 Type not recorded
No type recorded · USCGC BAINBRIDGE ISLAND (WPB 1343) · USCG Northeast District (CGD-NE) · Activity 1496716

Deficiency record · 21

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 September 2024 Resolved
(h) provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. When actuated, the automatic CO2 system will vent to atmosphere as both stbd and port engine room doors remain open underway to supply the prime movers with air. Vessel is given 30 days to submit plans for a ventilation plan that takes into account damper closures when automatic CO2 system is actuated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 5 May 2025
Resolution: Vessel completed construction of a small ventillation shaft and damper.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2022 Resolved
Conduct U/W trial prior to credit DDX.
Action required: 705 - Other - as specified
Due 20 September 2022
Resolved 30 December 2022
Resolution: Conduct U/W trial prior to credit DDX.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 June 2021 Resolved
First aid kit must meet approval type. Medication is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2021
Resolution: Replaced expired items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 June 2021 Resolved
Child and adult life jackets required to be seperated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2021
Resolution: Jackets seperated and locker relabled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2021 Resolved
Operation and instructions along with schematic must be posted at each pull station and CO2 bottle location.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2021
Resolution: Instructions and diagram posted
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 June 2021 Resolved
Light List, Coast Pilot and charts required to be current and appropriate for intended route.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 July 2021
Resolution: Provided photo documentation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2021 Resolved
CO2 system must include warning signage as outlined in 185.612(g)(1-3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 July 2021
Resolution: Warning signage posted
Construction/Loadline › Structures › Superstructure
Issued 31 October 2011 Resolved
Vessel is taken out of service until final inspection of coaming in way of pilothouse. Vessel representative has stated that rotten wood is to be removed and replaced in kind. Final inspection is to be to the satisfaction of the attending CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 August 2011 Resolved
Vessel must submit diagram documenting rot/damaged frames in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2011
Resolution: Operator submitted deck plan with updated condition of rotten/damaged frames. Plan added to MISLE documents.
Construction/Loadline › Hull › Transverse Frame
Issued 10 August 2011 Resolved
Vessel has 16 transverse frames in the engine room, 6 of which are dry rotted or cracked from the port bulkhead to starboard bulkhead. Vessel must submit 5 Year Repair Plan addressing all damaged frames. Vessel must replace 6 most damaged frames this year.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2012
Resolution: Failed inspection. Cleared deficiency for recordkeeping. Vesse will need new COI.
Construction/Loadline › Structures › Deck Plating
Issued 9 July 2009 Resolved
Properly seal flooring separating engine room and passenger accom. space.
Due 9 August 2009
Resolved 10 August 2009
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 9 July 2009 Resolved
Provide protective guard around shaft in engine room.
Due 9 August 2009
Resolved 10 August 2009
Documentation › Certificates/Documents › FCC SSL
Issued 5 August 2008 Resolved
Vsl is restricted to 1,000 fr from shore until vsl can provide proof of FCC Marine Operator permit and FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 8 August 2008
Resolution: Vsl provided proof of FCC Marine Operator permit and FCC Safety Certificate.
Documentation › Logs/Records › Drug Test Records
Issued 5 August 2008 Resolved
Vsl must provide proof of crew’s enrollment in DAPI program prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2008
Resolution: Vsl provided proof of DAPI enrollment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 August 2008 Resolved
Replace expired medication in 1st aid kit.
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 10 September 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 August 2008 Resolved
Make permanent repairs to hole found on the deck of the pilot house.
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 10 September 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 August 2008 Resolved
Replace floatlight batteries and label replacement day. Vsl is restricted to daylight operations.
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 6 August 2008
Resolution: Floatlight batteries were replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 August 2008 Resolved
Install missing light fixture guard IWO Engine Room.
Action required: 705 - Other - as specified
Due 5 September 2008
Resolved 10 September 2008
Stability › Watertight Integrity › General
Issued 22 May 2008 Resolved
Secure forward deck hatch IAW 46 CFR 179.360.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2008
Resolution: Forward deck hatch fixed with closure device, retaining chain and new gasket.
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 March 2007 Resolved
Provide donning placards for child size (vest type) life jackets.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 25 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 March 2007 Resolved
Put the two amp meter breakers IWO the alternator inside an enclosure.
Action required: 705 - Other - as specified
Due 1 June 2007
Resolved 1 June 2007