Documentation record
Registered dimensions (L × B × D)58.0 ft × 31.0 ft × 9.0 ft
Registered tonnagegross 60 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCATAMARANS NORTHWEST INC · ABERDEEN, WA, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeSail (Faired Keel)
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 4 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
54 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 19 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
21 January 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8299685
12 January 2026
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8297632
15 January 2025
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8063922
17 January 2024
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7850399
11 January 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7848425
9 January 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7619626
10 January 2022
COI Inspection · Hull Examination · In-Service Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7377132
22 April 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7180513
8 April 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6937051
6 January 2020
Hull Examination · Drydock Exam · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6883160
29 December 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6603790
14 July 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6479542
20 March 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6383368
11 January 2018
Drydock Exam · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6339220
23 January 2017
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6075229
14 September 2016
Type not recorded
No type recorded · USCGC PETREL (WPB 87350) · USCG Southwest District (CGD-SW) · Activity 6001143
21 July 2016
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5948099
25 May 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5886459
14 January 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5797359
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 21 January 2026
Resolved
Vessel's VFH radio did not show lat/long location and did not have the vessel's MMSI number programmed. Provide radio with lat/long and MMSI to enable SOS emergency functions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2026
Resolved 10 February 2026
Resolution: Received photo of new radio installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 January 2026
Resolved
The starboard-midships electrical submersible bilge pump failed to operate in manual operation. Make repairs and prove proper operation of manual function.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2026
Resolved 23 January 2026
Resolution: Bilge switch repaired and video of operation received.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 January 2023
Resolved
Float free link must be certified to meet 46CFR160.073
and be of proper strength for the size of the life float
or buoyant apparatus as indicated on its identification
tag. Until such time as you provide evidence weak link
is in accordance of 46CFR160.073 and the line on the
life float is replaced the aft life float is out of
service and passenger count is reduced to 44 while on a
limited coast wise voyage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 January 2023
Resolved 13 January 2023
Resolution: Recieved pictures of defs rectified
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 January 2023
Resolved
Painter and line on aft life float is deteriorated and
must be replaced. Life Float is out of service until
repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 January 2023
Resolution: Recieved pictures of defs rectified
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 January 2023
Resolved
FCC Station authorization expired as of April 2022.
Please provide current FCC Station authorization.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2023
Resolved 13 January 2023
Resolution: Recieved pictures of defs rectified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 January 2022
Resolved
Have 3rd party surveyor inspect mast step and provide report.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 22 January 2022
Resolution: Owner operator provided rigging report done by SD Boatworks.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 January 2022
Resolved
Replace batteries in float water light ensuring proper operation. Vessel is restricted to daylight operations.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2022
Resolution: Batteries were replaced by owner operator.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 January 2022
Resolved
Renew radio safety certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 20 January 2022
Resolution: owner operator provided new certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2021
Resolved
Provide 04 additional red hand or orange smoke distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 10 May 2021
Resolution: Owner emailed picture.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 April 2021
Resolved
Return 3rd life float to vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 10 May 2021
Resolution: Owner emailed picture.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 22 April 2021
Resolved
Provide emergency bullhorn at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 10 May 2021
Resolution: Owner emailed picture.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 April 2021
Resolved
Provide 03 (2.5 gallon) marked fire buckets w/ lanyard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2021
Resolved 10 May 2021
Resolution: Owner emailed picture.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 22 April 2021
Resolved
Provide guards around serpentine belts on both engines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 17 May 2021
Resolution: Guards made by owner were found satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2021
Resolved
Provide rigging preventative maintenance plan as per NVIC 02-16 Enclosure (1).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2021
Resolved 19 May 2021
Resolution: POC e-mailed Inventory and Maintencance Routine
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2020
Resolved
During annual inspection port side bilge high level alarm failed to give an audible indication at the operating station. Repair as needed to ensure proper alarm is given.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2020
Resolved 8 June 2020
Resolution: Proof of audible alarm received via video
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 23 January 2017
Resolved
Provide pre-employment drug test for crewmember.
Action required: 705 - Other - as specified
Due 23 February 2017
Resolved 26 January 2017
Resolution: Operator provided ACPA drug test result for crewmember pre-employment.