MAURY USCG vessel records Sign in
← All vessels

GRASSHOPPER

GRASSHOPPER is a 2002 freight ship. The Coast Guard has recorded 11 inspections since 2002, most recently in April 2017, along with 3 deficiencies and 2 operational controls.

Records from 2002 to 2017. Most recent: inspection, 18 April 2017.

Built
2002
Last inspected
18 April 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9254549 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
586345
Flag
MARSHALL ISLANDS
—
Maury page id
psix-586345

Inspections, by type

…with no type recorded3
Years with a record 5 calendar years (2002–2017)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it30000 - Convention (Subpart B), Gross Ton
18449 - Convention (Subpart B), Net Ton
61952 - Displacement, Ton
53146 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

18 April 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6127049
11 April 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6122307
21 April 2009 Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3457228
17 April 2009 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3454975
13 June 2008 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 3238984
11 June 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3224819
8 November 2004 Re-Inspection · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2236727
5 November 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2235704
27 February 2004 Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2014206
14 August 2002 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1661421
12 August 2002 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1665430

Deficiency record · 3

Navigation › Collision/Grounding Avoidance › Radar
Issued 17 April 2009 Resolved
Vessel issued LOD inbound for primary rader inop. Vessel must fix radar and fax over techinian report prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2009
Resolution: Sector Delaware Bay received technician''''s report via fax attesting to repair and proper operation of radar.
Lifesaving › Inflatable Liferafts › Servicing
Issued 13 June 2008 Resolved
All liferafts are off of the vessel to be serviced (required annual servicing). Ensure all liferafts are back on board, properly stowed and in working condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2008
Resolution: All liferafts were serviced and properly stowed back on vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 June 2008 Resolved
Portable fire extinguishers, EEBD's & SCBA's were due to be inspected May 2008. Vessel is having this inspection performed while in port of Morehead City, NC.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 June 2008
Resolution: All above equipment was inspected and properly stowed back on the vessel.

Ownership record