MAURY USCG vessel records Sign in
← All vessels

HERON

HERON is a 2002 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2002, most recently in July 2026, along with 39 deficiencies and 3 casualty investigations between 2009 and 2022.

Records from 2002 to 2026. Most recent: inspection, 21 July 2026.

Built
2002
Last inspected
21 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8975689 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB2084
586558
Flag
UNITED STATES
366872110
Maury page id
psix-586558

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (2002–2026)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)113.0 ft × 46.0 ft × 12.0 ft
Registered tonnagegross 87 / net 59
ITC dimensions (L × B × D)113.0 ft × 46.0 ft × 12.0 ft
ITC tonnagegross 268 / net 80
BuilderEASTERN SHIPBUILDING GROUP INC · PANAMA CITY, FL, UNITED STATES · built 2002
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFISHER ISLAND, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it87 - Regulatory (Subpart C or D), Gross Ton
268 - Convention (Subpart B), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
80 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB2084MMSI 366872110 · active · compulsorily equipped · granted 22 October 2022, expires 24 October 2032
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 38

21 July 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8444075
10 June 2026 Vessel Attendance · Examination of Repairs · Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8367234
10 September 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8197292
29 October 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8026017
27 June 2024 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7944416
4 November 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7821246
9 August 2022 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7516183
1 August 2022 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7529001
23 June 2022 Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7484694
3 November 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7344718
7 May 2021 Administrative Inspection · Construction Oversight
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7202603
20 November 2020 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7099078
29 June 2020 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6991457
20 February 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6912458
26 November 2019 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6861832
26 November 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6586858
4 June 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6433578
30 August 2017 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6249243
28 November 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6048353
18 May 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5878830
4 December 2015 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5775174
20 June 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4894048
21 June 2012 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4449027
12 June 2012 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4341564
29 December 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4215299
15 December 2010 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3910948
28 December 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3652488
23 January 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3398780
8 December 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3375995
29 October 2008 Drydock Extension
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3353670
3 October 2007 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3070180
15 May 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2930960
11 October 2006 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2802418
18 November 2004 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2243364
6 October 2004 Hull Examination · Deficiency Check · Drydock Extension
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2214642
21 October 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1932662
23 October 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1694702
1 October 2002 Initial Construction-Excluding Oversight · Inclining Experiment · Initial Certification · Plan Review "T" Boat
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1682756

Deficiency record · 39

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 September 2025 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. CO2 system does not have the required device to shut down the engines within the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2025
Resolved 22 September 2025
Resolution: Proper repairs made with satisfactory shut down.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. #1 MDE had a flexible hose with one broken hose clamp, correct on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 September 2025
Resolved 10 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2025 Resolved
Small batteries. Each small battery installation must be located in a well ventilated space and protected from falling objects. A small battery installation must not be in a closet, storeroom or similar space. Battery box covers were not secured. Corrected on the Spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 September 2025
Resolved 10 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2022 Resolved
Number 2 prop is showing some signs of cavitation. Repair prop to original spec.
Action required: 705 - Other - as specified
Resolved 24 July 2022
Resolution: Prop was sent to machine shop for repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 November 2020 Resolved
all machinery must be installed and maintained to afford adequate protection from personnel injury. cover the open hole on the cowling of both generators. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2020
Resolution: received email
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2020 Resolved
materials used in piping systems must be acceptable to cognizant OCMI. crossconnect valve between bilge and fire pump is corroded and leaking. 46 CFR 182.700
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2020
Resolution: received email
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2020 Resolved
each fixed power bilge pump required by 181.300 may serve as one of the two bilge pumps required. bilge pump packing is worn and leaking. replace packing or pump. 46 CFR 182.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 22 November 2020
Resolution: received email
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 November 2020 Resolved
all machinery must be installed and maintained to afford adequate protection from machinery failure. jacket water alarm is false alarming and cannot be reset. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 4 December 2020
Resolution: received email
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 December 2016 Resolved
Provide up to date chart.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 22 December 2016
Resolution: Up to date charts were provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 December 2016 Resolved
Provide Coast Pilot and Current tables.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 22 December 2016
Resolution: New coast pilot provided onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 December 2016 Resolved
Provide First Aid Kit approved under 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 22 December 2016
Resolution: First aid kit provided.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 December 2016 Resolved
Distribution panel in operating station needs to be labeled.
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 22 December 2016
Resolution: Distribution panel properly labeled.
Construction/Loadline › Hull › Bracket
Issued 18 May 2016 Resolved
Renew as original rudder angle indicator feedback mounting brackets both forward and aft due to wastage.
Action required: 705 - Other - as specified
Resolved 21 June 2016
Resolution: Vessel renewed as original rudder angle indicator feedback mounting brackets both forward and aft due to wastage.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 4 December 2015 Resolved
Repair oil leaks on exhaust manifolds and renew oil-soaked lagging, both SSDGs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 17 December 2015
Resolution: Observed satisfactory repair.
Construction/Loadline › Structures › Manhole
Issued 4 December 2015 Resolved
Repair hinge manhole nbr1 end steering compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 17 December 2015
Resolution: Observed satisfactory repair.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 December 2015 Resolved
Various items missing or expired from first aid kit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 17 December 2015
Resolution: Verified contents of first aid kit.
Construction/Loadline › Structures › Superstructure
Issued 23 June 2014 Resolved
Grind out and reweld fractured welds in way of bulwark support at connection to deck and top hand rail opposite house.
Due 23 June 2014
Resolved 5 August 2014
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 23 June 2014 Resolved
Replace chockfast fast where damaged and tighten loose main engine mount bolts.
Due 23 June 2014
Resolved 5 August 2014
Construction/Loadline › Hull › Hull Plating
Issued 23 June 2014 Resolved
Install inserts in way of overboard discharge valves where removed portside under house in side shell. Inserts are to be installed and NDT to the satisfaction of attending Coast Guard Marine inspector.
Due 23 June 2014
Resolved 5 August 2014
Construction/Loadline › Hull › Stiffener
Issued 12 June 2012 Resolved
Crop and renew angle iron under deck IWO hatch in #1 wrap around compartment, wheel house side.
Action required: 705 - Other - as specified
Due 12 July 2012
Resolved 21 June 2012
Electrical › Electric Supply System (service) › Battery Charger
Issued 29 December 2011 Resolved
Provide ammeter IAW 46 CFR183.350(f) for battery charger.
Action required: 705 - Other - as specified
Due 12 January 2012
Resolved 18 January 2012
Engineering › Bilge Water Management System › Pump
Issued 29 December 2011 Resolved
Service both the fire pump and bilge pump due to heavy salt deposits.
Action required: 705 - Other - as specified
Due 12 January 2012
Resolved 18 January 2012
Fire Fighting › Fire Pumps › Power Source
Issued 29 December 2011 Resolved
IAW 46 CFR183.320(b), show that fire pump and other motors are rated @ 50c ambient temp, or that motor was derated to 80%, or that engine room does not exceed 40c.
Action required: 705 - Other - as specified
Due 12 January 2012
Resolved 18 January 2012
Engineering › Bilge Water Management System › Pump
Issued 15 December 2010 Resolved
Prove proper operation of stripping bilge pump in #1 shaft alley space.
Action required: 705 - Other - as specified
Due 22 December 2010
Resolved 21 December 2010
Resolution: Pump not required, pump removed, electrical and overboard properly secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 December 2009 Resolved
Properly terminate in a junction box or remove dead ended wires on engine and at both operating stations.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 4 January 2010
Communications › Radio Communications › Emergency Source of Power
Issued 28 December 2009 Resolved
Remove debris and water from battery box on #1 side.
Action required: 705 - Other - as specified
Due 4 January 2010
Resolved 4 January 2010
Engineering › Bilge Water Management System › Strainer
Issued 8 December 2008 Resolved
Repair/replace bilge strainers in shaft alley #2 end, steering compartment #2 end and wrap around #2 end. To be completed prior to credit dry-dock.
Action required: 705 - Other - as specified
Resolved 23 January 2009
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 December 2008 Resolved
Make repairs to all hatch covers so that they are attached (current arrangement they can be removed). To be completed prior to credit dry-dock.
Action required: 705 - Other - as specified
Resolved 23 January 2009
Engineering › Bilge Water Management System › Not Operational
Issued 11 October 2006 Resolved
After Dry Dock VSL Bilge system must be tested satisfactorily prior to VSL operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2006
Fire Fighting › Fire Main › Condition
Issued 11 October 2006 Resolved
After major modification prove proper operation of fire main prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2006
Engineering › Bilge Water Management System › Strainer
Issued 11 October 2006 Resolved
Bilge Strainer deteriorated in Hole #5.
Due 20 October 2006
Resolved 13 December 2006
Engineering › Bilge Water Management System › Piping
Issued 26 October 2004 Resolved
Prove bigle de-watering system and alarms in all compartments.
Due 26 November 2004
Resolved 18 November 2004
Documentation › Certificates/Documents › Stability Letter
Issued 26 October 2004 Resolved
Provide onboard a copy of lead ballast distribution diagram.
Due 26 November 2004
Resolved 28 October 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 October 2004 Resolved
Remove or prove safe dead ended cable in shaft void space at each end.
Due 26 November 2004
Resolved 18 November 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 October 2004 Resolved
Remove boat plug and cap pipe penetration at WTB of #2 rudder compartment.
Due 26 November 2004
Resolved 18 November 2004
Documentation › Certificates/Documents
Issued 1 October 2002 Resolved
Post Stability letter upon reciept, prior to carrying passengers for hire LEGACY COMPONENT DESC: Stability Letter
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2002
Resolved 23 October 2002
Resolution: Stability letter posted on the bridge.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 1 October 2002 Resolved
Make appropriatemodifications to the anchor retreaval device to the satisfaction of the attending marine inspector prior to 11-4-2002
Due 4 November 2002
Resolved 4 October 2002
Resolution: S/Y added an additional stopper device to aid in retreaval.
Operations/Management › Drills/Instruction
Issued 1 October 2002 Resolved
Demonstrate proper fire and boat drill to the satisfaction of the attending marine inspector, prior to carrying passengers for hire. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2002
Resolved 23 October 2002
Resolution: Successfully conducted MOB and fire drill.
Construction/Loadline › Structures › Ventilators
Issued 1 October 2002 Resolved
Provide machinery space ventilation drawing 01-886-7030 resubmittal .
Due 4 November 2002
Resolved 4 October 2002
Resolution: Drawing has been approved IAW MSC letter dated 01 Oct 02.

Casualty record · 3

11 October 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3613483
12 March 2011Routine · role: Transiting Vicinity of Primary Subject · activity 3964676
1 August 2022Routine · role: Involved in a Marine Casualty · activity 7529001
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.