Records from 2016 to 2026. Most recent: inspection, 22 June 2026.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 13.0 ft × 3.5 ft
Registered tonnagegross 14 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLASS BOAT WORKS INC · EXMORE, VA, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portKENT NARROWS, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
22 June 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8420251
22 January 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8301854
2 June 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8151675
27 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8070378
28 December 2024
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8057196
1 July 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7946475
15 September 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7792073
5 September 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7785122
13 March 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7650116
26 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7628119
13 June 2022
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7470734
7 June 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7229081
11 January 2021
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7123769
29 June 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7024067
25 March 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6651278
29 January 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6618079
10 January 2018
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6335383
19 June 2017
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6187341
21 February 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6093439
13 May 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5858487
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 July 2024
Resolved
11127 - A substantial nameplate must be permanently attached to each buoyant apparatus. The nameplate must contain the manufacturer, lot designation or serial number, approval number, dimensions, and number of persons capacity. Space must be provided for the date, and the identification of the independent laboratory. The vessel's life float is missing the nameplate. The vessel may only operate in warm water months.
46 CFR 180.200(a)(2)
46 CFR 160.010-8
Action required: 705 - Other - as specified
Resolved 28 December 2024
Resolution: Vessel owner purchased a new life float.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 September 2023
Resolved
A substantial nameplate must be permanently attached to each buoyant apparatus. The nameplate must contain the name of the manufacturer, lot designation or serial number, approval number, dimensions, and number of persons capacity. Space must be provided for the date, and the identification of the independent laboratory. Vessel's life float is missing nameplate.
46CFR160.010-8
Action required: 705 - Other - as specified
Due 1 November 2023
Resolved 1 July 2024
Resolution: The nameplate is not attached to the life float. The vessel was issued a new CG-835v restricting them to operating in warm water months only.
Lifesaving › Lifefloat › Retroreflective Material
Issued 19 June 2017
Resolved
Apply SOLAS Type II tape
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 24 July 2017
Engineering › Steering Gear System › Rudder
Issued 19 June 2017
Resolved
Repair/Replace packing for rudder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 24 July 2017