Records from 2016 to 2024. Most recent: inspection, 4 February 2024.
Inspection history · 20
4 February 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7856648
17 October 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7804969
10 January 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619492
9 January 2023
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7615705
18 June 2022
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7465360
27 June 2021
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7238241
23 January 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7129533
1 July 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6998113
9 June 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6972161
25 April 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6943799
20 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6941486
18 June 2019
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6712533
14 December 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6594631
17 April 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6389703
10 December 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6321741
14 September 2017
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6253830
27 May 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6156934
3 October 2016
Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6014456
27 June 2016
COE-Dockside · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5911842
23 February 2016
Ballast Water Examination · ISPS III Exam · Deficiency Check · Administrative Inspection · COE-Dockside · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5814735
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 December 2018
Resolved
A fireman's outfit shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The fireman's outfits onboard the vessel left a significant amount of skin exposed around the neck and ears.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2018
Resolved 14 December 2018
Resolution: Vessel submitted proof of purchase of new flash hoods.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 September 2017
Resolved
0999-The machinery, boilers and other pressure vessel, associated piping and fittings shall be of a design and construction adequate for service intended, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed no lagging on E-generator turbo. SOLAS 74a (09) II-1/26.1 50c
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 10 December 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 14 September 2017
Resolved
2410Those ships using separate fuel oils to comply with para. 4 of this regulation and entering or leaving an emission control area set forth in para. 3 shall carry a written procedure showing how the fuel oil change over is to be done. Vessel’s change over procedures are not ship specific and give no detail of action to be completed (i.e. valves to be isolated or steam lines secured)MARPOL VI14.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 10 December 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 3 October 2016
Resolved
1499- A second source of energy shall be provided for an additional 3 starts within 30 min. unless manual starting can be effective. C/E notified PSCO thet the secondary batteries were not strong enough to start EDG. PSCO observed satisfactory starting of EDG under primary batteries. SOLAS 74a(09) II-1/44.2 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2016
Resolved 14 October 2016
Resolution: Received a class report from DNV-GL stating that the deficiency was rectified. Ships crew replaced batteires.
Fire Fighting › Fire Main › Condition
Issued 23 February 2016
Resolved
0799- Vessels fire main is holed on the discharge side of the main fire pump, resulting in water ingress into the engine room. 74SOLAS (14 cons) I-11(a) Action taken: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2016
Resolution: Received Class Report attesting to repairs.