MAURY USCG vessel records
← All vessels

SALVADOR

SALVADOR is a 2002 freight ship. The Coast Guard has recorded 20 inspections since 2016, most recently in February 2024, along with 5 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 4 February 2024.

Built
2002
Last inspected
4 February 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9255062
588414
Flag
CYPRUS
Maury page id
psix-588414

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it19746 - Convention (Subpart B), Gross Ton
39034 - Displacement, Metric Ton
31770 - Dead Weight, Metric Ton
10669 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

4 February 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7856648
17 October 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7804969
10 January 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619492
9 January 2023 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7615705
18 June 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7465360
27 June 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7238241
23 January 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7129533
1 July 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6998113
9 June 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6972161
25 April 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6943799
20 April 2020 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6941486
18 June 2019 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6712533
14 December 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6594631
17 April 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6389703
10 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6321741
14 September 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6253830
27 May 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6156934
3 October 2016 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6014456
27 June 2016 COE-Dockside · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5911842
23 February 2016 Ballast Water Examination · ISPS III Exam · Deficiency Check · Administrative Inspection · COE-Dockside · PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5814735

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 December 2018 Resolved
A fireman's outfit shall consist of protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The fireman's outfits onboard the vessel left a significant amount of skin exposed around the neck and ears.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2018
Resolved 14 December 2018
Resolution: Vessel submitted proof of purchase of new flash hoods.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 September 2017 Resolved
0999-The machinery, boilers and other pressure vessel, associated piping and fittings shall be of a design and construction adequate for service intended, due regard being paid to moving parts, hot surfaces and other hazards. PSCO observed no lagging on E-generator turbo. SOLAS 74a (09) II-1/26.1 50c
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 10 December 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 14 September 2017 Resolved
2410Those ships using separate fuel oils to comply with para. 4 of this regulation and entering or leaving an emission control area set forth in para. 3 shall carry a written procedure showing how the fuel oil change over is to be done. Vessel’s change over procedures are not ship specific and give no detail of action to be completed (i.e. valves to be isolated or steam lines secured)MARPOL VI14.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 10 December 2017
Resolution: PSC NOLA received a class report from DNV-GL satisfying the requirement
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 3 October 2016 Resolved
1499- A second source of energy shall be provided for an additional 3 starts within 30 min. unless manual starting can be effective. C/E notified PSCO thet the secondary batteries were not strong enough to start EDG. PSCO observed satisfactory starting of EDG under primary batteries. SOLAS 74a(09) II-1/44.2 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 3 October 2016
Resolved 14 October 2016
Resolution: Received a class report from DNV-GL stating that the deficiency was rectified. Ships crew replaced batteires.
Fire Fighting › Fire Main › Condition
Issued 23 February 2016 Resolved
0799- Vessels fire main is holed on the discharge side of the main fire pump, resulting in water ingress into the engine room. 74SOLAS (14 cons) I-11(a) Action taken: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2016
Resolution: Received Class Report attesting to repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.