MAURY USCG vessel records
← All vessels

WACCAMAW LADY

WACCAMAW LADY is a 2002 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in March 2026, along with 24 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 25 March 2026.

Built
2002
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

588561
Flag
UNITED STATES
Maury page id
psix-588561

Documentation record

Registered dimensions (L × B × D)54.0 ft × 14.3 ft × 4.9 ft
Registered tonnagegross 52 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUSQUEHANNA SANTEE BOATWORKS, · LANCASTER, PA, UNITED STATES · built 2002
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Simplified, Gross Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

25 March 2026 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8332312
24 March 2025 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8093760
10 December 2024 Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8046314
10 June 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7932851
26 June 2023 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7727201
11 July 2022 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7500629
9 July 2021 Examination of Repairs · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7240244
10 April 2020 COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6934041
17 December 2019 Drydock Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6888053
15 July 2019 Deficiency Check · Examination of Repairs · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6728801
16 July 2018 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6452467
17 July 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6215049
16 May 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5878739

Deficiency record · 24

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2021 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed. Existing mounting brackets for outboard motors were found fractured in way of port & starboard sides.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 July 2021 Resolved
Vessel required to be equipped with operable navigational lights as prescribed by USCG NAVRULES. Starboard navigational side light was found extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2021 Resolved
Vessel required to carry an approved/serviceable PFD for each person on board. Condemned one adult Type I PFD due to unserviceability.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 9 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2021 Resolved
Vessels ring life buoy required to be equipped with an operable floating water light. Existing water light was found damaged/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2021 Resolved
Vessels floating water light required to be attached to ring life buoy. Existing floating waterlight was not attached with required lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2021 Resolved
Vessel required to be equipped with three (03) fire buckets. Vessel was equipped with two (02) fire buckets w/lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2021 Resolved
Flexible fuel lines are authorized for lube oil, fuel oil and fluid power systems. Existing fuel oil lines between primer bulb and outboard (main) engines were found cracked/deteriorated (UV).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2021
Resolved 10 December 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 December 2019 Resolved
Attending Inspector noted loose mounting hardware between sponsons and cross deck structure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 19 December 2019
Resolution: O/O adjusted/tightened mounting hardware.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 December 2019 Resolved
Fractured weldment IWO port transverse frame, port side (#15 measured aft from bow).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 19 December 2019
Resolution: O/O installed a "sister" frame IWO affected area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 July 2019 Resolved
Emergency fuel shut-off valves were not properly marked with direction of operation (on/off).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified markings for emergency fuel shut-off valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019 Resolved
Vessels primary fuel lines between the fuel filter and outboard motors were deteriorated (UV).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified renewal of fuel lines for outboard motors.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 July 2019 Resolved
Vessels name/hailing port were not marked IWO port/starboard bow & stern IAW 46 CFR 67.123.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 17 December 2019
Resolution: Attending Inspector discussed marking requirements with vessels O/O. Vessel is equipped with signage along the aft main deck (port/starboard) with the vessels name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019 Resolved
Vessels gasoline fuel tanks ventilation assemblies were missing flame screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified renewal/installation of flame screens for fuel tank vent pipes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019 Resolved
Vessels centerline gasoline fuel tank fills were not properly bonded.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 17 December 2019
Resolution: Attending Inspector verified vessels fuel fill/tank installation. No bonding is required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019 Resolved
Electrical conduit brackets fractured IWO port/starboard canopy @ bow area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified repairs made to PVC conduit brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019 Resolved
Electrical wire nuts are not properly secured IWO operators console & aft sewage tank (transom).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified securing of electrical wire nuts IWO console/sewage tank.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 July 2019 Resolved
Type III MSD system missing operating instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified posting of operating instructions for MSD system.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 July 2019 Resolved
Vessels navigational publications were expired/out of date for areas transited.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified carriage of current/up to date navigational publications.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019 Resolved
Battery conductor outer jacketing was cracked/deteriorated/not of the proper type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 17 December 2019
Resolution: Attending Inspector verified repairs made to battery conductors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 July 2017 Resolved
Floating waterlight battery was installed improperly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of proper type of battery & verified markings for installation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 July 2017 Resolved
Wire nuts, where utilized, were not secured/terminated properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified securing/removal of wire nuts throughout electrical distribution system.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 July 2017 Resolved
Emergency fuel shutoff valve markings were missing/not installed.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified markings for remote/emergency fuel shut-off valves.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 July 2017 Resolved
Floating waterlight line was missing/not installed.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of proper type/length of line for floating waterlight.
Documentation › Markings/Placards › Warning Signs
Issued 17 July 2017 Resolved
Vessels emergency escapes were not properly marked/identified.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified posting of emergency escape markings.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.