Records from 2016 to 2026. Most recent: inspection, 25 March 2026.
Inspection history · 13
25 March 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8332312
24 March 2025
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8093760
10 December 2024
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8046314
10 June 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7932851
26 June 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7727201
11 July 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7500629
9 July 2021
Examination of Repairs · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7240244
10 April 2020
COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6934041
17 December 2019
Drydock Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6888053
15 July 2019
Deficiency Check · Examination of Repairs · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6728801
16 July 2018
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6452467
17 July 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6215049
16 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5878739
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed. Existing mounting brackets for outboard motors were found fractured in way of port & starboard sides.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 July 2021
Resolved
Vessel required to be equipped with operable navigational lights as prescribed by USCG NAVRULES. Starboard navigational side light was found extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2021
Resolved
Vessel required to carry an approved/serviceable PFD for each person on board. Condemned one adult Type I PFD due to unserviceability.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 9 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2021
Resolved
Vessels ring life buoy required to be equipped with an operable floating water light. Existing water light was found damaged/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2021
Resolved
Vessels floating water light required to be attached to ring life buoy. Existing floating waterlight was not attached with required lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2021
Resolved
Vessel required to be equipped with three (03) fire buckets. Vessel was equipped with two (02) fire buckets w/lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2021
Resolved
Flexible fuel lines are authorized for lube oil, fuel oil and fluid power systems. Existing fuel oil lines between primer bulb and outboard (main) engines were found cracked/deteriorated (UV).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2021
Resolved 10 December 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 December 2019
Resolved
Attending Inspector noted loose mounting hardware between sponsons and cross deck structure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 19 December 2019
Resolution: O/O adjusted/tightened mounting hardware.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 December 2019
Resolved
Fractured weldment IWO port transverse frame, port side (#15 measured aft from bow).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 19 December 2019
Resolution: O/O installed a "sister" frame IWO affected area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 July 2019
Resolved
Emergency fuel shut-off valves were not properly marked with direction of operation (on/off).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified markings for emergency fuel shut-off valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019
Resolved
Vessels primary fuel lines between the fuel filter and outboard motors were deteriorated (UV).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified renewal of fuel lines for outboard motors.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 July 2019
Resolved
Vessels name/hailing port were not marked IWO port/starboard bow & stern IAW 46 CFR 67.123.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 17 December 2019
Resolution: Attending Inspector discussed marking requirements with vessels O/O. Vessel is equipped with signage along the aft main deck (port/starboard) with the vessels name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019
Resolved
Vessels gasoline fuel tanks ventilation assemblies were missing flame screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified renewal/installation of flame screens for fuel tank vent pipes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019
Resolved
Vessels centerline gasoline fuel tank fills were not properly bonded.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 17 December 2019
Resolution: Attending Inspector verified vessels fuel fill/tank installation. No bonding is required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019
Resolved
Electrical conduit brackets fractured IWO port/starboard canopy @ bow area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified repairs made to PVC conduit brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019
Resolved
Electrical wire nuts are not properly secured IWO operators console & aft sewage tank (transom).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified securing of electrical wire nuts IWO console/sewage tank.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 July 2019
Resolved
Type III MSD system missing operating instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified posting of operating instructions for MSD system.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 July 2019
Resolved
Vessels navigational publications were expired/out of date for areas transited.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified carriage of current/up to date navigational publications.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019
Resolved
Battery conductor outer jacketing was cracked/deteriorated/not of the proper type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 17 December 2019
Resolution: Attending Inspector verified repairs made to battery conductors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 July 2017
Resolved
Floating waterlight battery was installed improperly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of proper type of battery & verified markings for installation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 July 2017
Resolved
Wire nuts, where utilized, were not secured/terminated properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified securing/removal of wire nuts throughout electrical distribution system.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 July 2017
Resolved
Emergency fuel shutoff valve markings were missing/not installed.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified markings for remote/emergency fuel shut-off valves.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 July 2017
Resolved
Floating waterlight line was missing/not installed.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of proper type/length of line for floating waterlight.
Documentation › Markings/Placards › Warning Signs
Issued 17 July 2017
Resolved
Vessels emergency escapes were not properly marked/identified.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified posting of emergency escape markings.