Records from 2002 to 2026. Most recent: inspection, 25 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
25 March 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8332312
24 March 2025
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8093760
10 December 2024
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8046314
10 June 2024
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7932851
26 June 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7727201
11 July 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7500629
9 July 2021
Examination of Repairs · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7240244
10 April 2020
COI Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6934041
17 December 2019
Drydock Exam · Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6888053
15 July 2019
Deficiency Check · Examination of Repairs · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6728801
16 July 2018
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6452467
17 July 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6215049
16 May 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5878739
30 July 2012
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4395091
8 August 2011
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 4109376
4 March 2010
Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3689855
7 July 2009
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 3526489
25 August 2008
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3308744
30 May 2007
Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2946356
29 August 2006
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2763216
24 May 2005
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2376038
2 May 2005
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2347535
29 April 2005
Simplified Stability Test
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2359601
16 November 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2241969
21 September 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2200967
6 April 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2038503
13 March 2004
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2023717
12 March 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2050841
9 March 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2021045
3 December 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1958073
3 September 2002
Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1670063
8 July 2002
Plan Review "T" Boat · Simplified Stability Test · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1661805
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2021
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed. Existing mounting brackets for outboard motors were found fractured in way of port & starboard sides.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 July 2021
Resolved
Vessel required to be equipped with operable navigational lights as prescribed by USCG NAVRULES. Starboard navigational side light was found extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2021
Resolved
Vessel required to carry an approved/serviceable PFD for each person on board. Condemned one adult Type I PFD due to unserviceability.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 9 September 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2021
Resolved
Vessels ring life buoy required to be equipped with an operable floating water light. Existing water light was found damaged/inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2021
Resolved
Vessels floating water light required to be attached to ring life buoy. Existing floating waterlight was not attached with required lanyard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2021
Resolved
Vessel required to be equipped with three (03) fire buckets. Vessel was equipped with two (02) fire buckets w/lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2021
Resolved 31 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2021
Resolved
Flexible fuel lines are authorized for lube oil, fuel oil and fluid power systems. Existing fuel oil lines between primer bulb and outboard (main) engines were found cracked/deteriorated (UV).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2021
Resolved 10 December 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 December 2019
Resolved
Attending Inspector noted loose mounting hardware between sponsons and cross deck structure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 19 December 2019
Resolution: O/O adjusted/tightened mounting hardware.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 December 2019
Resolved
Fractured weldment IWO port transverse frame, port side (#15 measured aft from bow).
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 January 2020
Resolved 19 December 2019
Resolution: O/O installed a "sister" frame IWO affected area.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 July 2019
Resolved
Emergency fuel shut-off valves were not properly marked with direction of operation (on/off).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified markings for emergency fuel shut-off valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019
Resolved
Vessels primary fuel lines between the fuel filter and outboard motors were deteriorated (UV).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified renewal of fuel lines for outboard motors.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 July 2019
Resolved
Vessels name/hailing port were not marked IWO port/starboard bow & stern IAW 46 CFR 67.123.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 17 December 2019
Resolution: Attending Inspector discussed marking requirements with vessels O/O. Vessel is equipped with signage along the aft main deck (port/starboard) with the vessels name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019
Resolved
Vessels gasoline fuel tanks ventilation assemblies were missing flame screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified renewal/installation of flame screens for fuel tank vent pipes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2019
Resolved
Vessels centerline gasoline fuel tank fills were not properly bonded.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 17 December 2019
Resolution: Attending Inspector verified vessels fuel fill/tank installation. No bonding is required.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019
Resolved
Electrical conduit brackets fractured IWO port/starboard canopy @ bow area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified repairs made to PVC conduit brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019
Resolved
Electrical wire nuts are not properly secured IWO operators console & aft sewage tank (transom).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified securing of electrical wire nuts IWO console/sewage tank.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 July 2019
Resolved
Type III MSD system missing operating instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified posting of operating instructions for MSD system.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 July 2019
Resolved
Vessels navigational publications were expired/out of date for areas transited.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2019
Resolved 30 July 2019
Resolution: Attending Inspector verified carriage of current/up to date navigational publications.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2019
Resolved
Battery conductor outer jacketing was cracked/deteriorated/not of the proper type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2019
Resolved 17 December 2019
Resolution: Attending Inspector verified repairs made to battery conductors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 July 2017
Resolved
Floating waterlight battery was installed improperly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of proper type of battery & verified markings for installation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 July 2017
Resolved
Wire nuts, where utilized, were not secured/terminated properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified securing/removal of wire nuts throughout electrical distribution system.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 July 2017
Resolved
Emergency fuel shutoff valve markings were missing/not installed.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified markings for remote/emergency fuel shut-off valves.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 July 2017
Resolved
Floating waterlight line was missing/not installed.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation of proper type/length of line for floating waterlight.
Documentation › Markings/Placards › Warning Signs
Issued 17 July 2017
Resolved
Vessels emergency escapes were not properly marked/identified.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified posting of emergency escape markings.
Lifesaving › Hand Flares › Quantity
Issued 30 July 2012
Resolved
Missing 02 flares on board.
Action required: 705 - Other - as specified
Resolved 31 July 2012
Fire Fighting › Fire Bucket › Stenciling
Issued 30 July 2012
Resolved
Fire Buckets were not properly labeled.
Action required: 705 - Other - as specified
Resolved 31 July 2012
Construction/Loadline › Hull › Weld
Issued 4 March 2010
Resolved
Properly repair 04 marked welds
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 March 2010
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 4 March 2010
Resolved
Provide proper fire extinguisher bracket for starboard engine extinguisher
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 5 March 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 August 2008
Resolved
Provide new life line for the life ring and place in an area that is readily accessible and available to personal on board the vessel.
Condition: Improper/Lack of Maintenance
Due 8 September 2008
Resolved 8 September 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 August 2008
Resolved
Provide number of life jackets in the storage areas.
Condition: Placed in Improper Service
Due 8 September 2008
Resolved 8 September 2008
Lifesaving › Rescue Boat Equipment › Electric Torch
Issued 25 August 2008
Resolved
Provide 01 flashlights.
Condition: Improper/Lack of Maintenance
Due 8 September 2008
Resolved 8 September 2008
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 25 August 2008
Resolved
Provide current CPR card for 50% of the crew.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 September 2008
Construction/Loadline › Hull › Weld
Issued 25 August 2008
Resolved
Repair cracks on the port and starboard engine mounts properly.
Condition: Improper/Lack of Maintenance
Due 8 September 2008
Resolved 8 September 2008
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 25 August 2008
Resolved
Provide hailing point on stern of vessel.
Condition: Improper/Lack of Maintenance
Due 8 September 2008
Resolved 8 September 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 August 2006
Resolved
Provide proof of enrollment in drug consortium for mate
Condition: Unknown
Due 11 September 2006
Resolved 12 September 2006
Resolution: Provided enrollment info.
Lifesaving › Hand Flares › Storage
Issued 29 August 2006
Resolved
Stencil flare box "distress flares"
Condition: Improper/Lack of Maintenance
Due 11 September 2006
Resolved 12 September 2006
Resolution: Properly stenciled flare box.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 29 August 2006
Resolved
Provide emergency brdcst placard.
Condition: Unknown
Due 11 September 2006
Resolved 12 September 2006
Resolution: Posted brdcst placard.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 29 August 2006
Resolved
Provide second flashlight.
Condition: Unknown
Due 11 September 2006
Resolved 12 September 2006
Resolution: Purchased second flashlight
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 August 2006
Resolved
Provide covers for vessels batteries
Condition: Placed in Improper Service
Due 11 September 2006
Resolved 12 September 2006
Resolution: Installed new covers.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 August 2006
Resolved
Repair/replace stern light.
Condition: Improper/Lack of Maintenance
Due 11 September 2006
Resolved 12 September 2006
Resolution: Repaired stern light
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 29 August 2006
Resolved
Provide 30X30 mesh flame screen for port side fuel vent.
Condition: Unknown
Due 11 September 2006
Resolved 12 September 2006
Resolution: Installed new flame screen.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 29 August 2006
Resolved
Repair/replace ring buoy light rescue light.
Condition: Improper/Lack of Maintenance
Due 11 September 2006
Resolved 12 September 2006
Resolution: Installed light.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 May 2005
Resolved
O/O to provide proof of enrollment/coverage of employees under drug consortium
Condition: Placed in Improper Service
Due 15 June 2005
Resolved 7 June 2005
Resolution: Provided proof of enrollment
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 24 May 2005
Resolved
O/O to post emergency broadcast instruction near radio operation station.
Condition: Unknown
Due 15 June 2005
Resolved 7 June 2005
Resolution: Provided instruction at radio station
Lifesaving › Rescue Boat Equipment › Boat-hook/Safety Boat-hook
Issued 24 May 2005
Resolved
Vessel does not have a rescue boat, but is required to have a boat hook to assist in MOB drills/situations due to height of deck from waterline.
Condition: Unknown
Due 15 June 2005
Resolved 7 June 2005
Resolution: Boat hook taken from extras in storage.
Stability
Issued 6 April 2004
Resolved
Prior to June 30, 2004, demonstrate compliance with the subdivision reuqirements in 46 CFR 179.210 and 46 CFR 179.212, to the satisfaction of the OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2004
Resolved 16 April 2004
Lifesaving › Lifebuoys
Issued 3 September 2002
Resolved
ATTATCH RETRO-REFLECTIVE TAPE TO LIFE RING BUOY.
Action required: 705 - Other - as specified
Due 3 October 2002
Resolved 2 October 2002
Resolution: SOLAS TAPE PLACED ON FRONT AND BACK OF LIFE RING BUOY.
Communications › Internal Communications System
Issued 3 September 2002
Resolved
INSTALL PUBLIC ADDRESS SYSTEM AND TEST.
Action required: 705 - Other - as specified
Due 3 October 2002
Resolved 2 October 2002
Resolution: INSTALLED PA SYSTEM AND TESTED.
Lifesaving
Issued 3 September 2002
Resolved
PROVIDE A MEANS TO RETRIEVE A PERSON IN THE WATER.
Action required: 705 - Other - as specified
Due 3 October 2002
Resolved 2 October 2002
Resolution: INSTALLED STAINLESS STEEL BOARDING LADDER THAT EXTENDS 18" BELOW WATERLINE.
Construction/Loadline › Structures
Issued 3 September 2002
Resolved
MAKE GATES OPEN IN THE DIRECTION OF EGRESS. LEGACY COMPONENT DESC: Superstructure
Action required: 705 - Other - as specified
Due 3 October 2002
Resolved 2 October 2002
Resolution: REMOVED GATES, INSTALLED TWO 1/2" LINES W/CLIPS TO SECURE OPENING. GATES WERE DRAGGING AGAINST AND RUINING DECK.
Construction/Loadline › Markings
Issued 3 September 2002
Resolved
ATTACH NAME OF VESSEL TO TRANSOM. LEGACY COMPONENT DESC: Vessel Name/Home Port
Action required: 705 - Other - as specified
Due 3 October 2002
Resolved 2 October 2002
Resolution: NAME AND PORT ON STERN.
Documentation › Certificates/Documents
Issued 3 September 2002
Resolved
DOCUMENT VESSEL THROUGH THE NATIONAL VESSEL DOCUMENTATION CENTER. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2002
Resolution: VESSEL DOCUMENTED THROUGH NVDC.