MAURY USCG vessel records Sign in
← All vessels

PATRIOT II

PATRIOT II is a 2003 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 2001, most recently in August 2020, along with 122 deficiencies, 2 operational controls and 4 casualty investigations between 2005 and 2012.

Records from 2001 to 2020. Most recent: inspection, 31 August 2020.

Built
2003
Last inspected
31 August 2020
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF3327
589279
Flag
UNITED STATES
366880080, 367438610 (licence lapsed)
Maury page id
psix-589279

Inspections, by type

…with no type recorded5
Years with a record 16 calendar years (2001–2020)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)72.0 ft × 26.0 ft × 7.0 ft
Registered tonnagegross 59 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK BOAT WORKS · TUCKAHOE, NJ, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portWEEHAWKEN, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it59 - Simplified, Gross Ton
47 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF3327MMSI 367438610 · expired · compulsorily equipped · granted 3 February 2010, cancelled 4 April 2020
WDB2815MMSI 366880080 · expired · compulsorily equipped · granted 30 January 2003, cancelled 8 April 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 43

31 August 2020 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7046479
25 August 2020 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7042594
10 December 2019 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6871310
26 November 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6863001
23 November 2019 In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6862367
25 September 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6820002
3 September 2019 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6802812
6 November 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6575236
26 June 2018 Deadweight Survey · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6465180
20 September 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6269417
14 July 2017 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6209131
7 July 2017 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6200861
7 September 2016 Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6005718
8 September 2015 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5753062
19 August 2014 MTSA Verification · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4961278
9 May 2012 Internal Structural Exam · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4307391
16 March 2010 COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3701079
13 January 2010 COI Inspection · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3663057
22 October 2008 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3349357
11 April 2008 Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3185436
16 March 2007 Examination of Repairs · In-Service Inspection · Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2888998
30 June 2006 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2696418
6 June 2006 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2671760
22 June 2005 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2431201
17 May 2005 Examination of Repairs · Damage Survey
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2363073
27 April 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2344039
3 April 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2343926
1 April 2005 Examination of Repairs
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2324361
16 February 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2318596
16 February 2005 Damage Survey · Examination of Repairs
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2319344
3 January 2005 Plan Review "T" Boat · Damage Survey · Examination of Repairs
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2269540
30 November 2004 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2250250
24 August 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2174970
19 August 2004 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2174909
7 June 2004 In-Service Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2126949
20 May 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2072813
8 March 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2020680
10 September 2003 Construction Oversight · Administrative Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1955095
2 June 2003 Administrative Inspection · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1810106
25 May 2003 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1828366
5 May 2003 MARPOL Annex V Examination · Deficiency Check · In-Service Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1786711
2 April 2003 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770169
11 January 2001 Plan Review "T" Boat · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1744611

Deficiency record · 122

07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 December 2019 Resolved
A fan cover within an the duct was obstructing the operation of the starboard side engine room air damper. Re-secure fan cover.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: Fan cover removed, witnessed operation of dampener, All SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 December 2019 Resolved
A puddle of oil was found under the port side generator. Determine the source of the oil and repair as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 19 August 2020
Resolution: Satisfactory repairs to generator completed and all oil removed below. SAT OPTEST completed of generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 December 2019 Resolved
Upon starting the starboard side generator, exhaust became present in the space. Determine the source of the exhaust and repair as necessary
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: MI witnessed operation of STBD generator, no exhaust leaks visible, All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2019 Resolved
A wire splice aft of the starboard side steering gear was not in a junction box; This work occurred after the 23 Nov inspection. Place wire splice in an appropriate junction box.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: All wires placed inside junction box, All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2019 Resolved
The base of the rudder post bearing of starboard rudder was fractured. Repair or replace bearing as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: STBD side rudder bearing replaced satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 12 December 2019 Resolved
Port side generator missing machinery guard. Install machinery guard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: Machinery guard on Port generator installed satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2019 Resolved
VESSEL REPORTED CASUALTY TO #1 GENERATOR. SUBMIT WRITTEN AND SIGNED CAUSAL ANALYSIS. SUBMIT TECHNICAL REPORT STATING THAT GENERATOR IS FULLY FUNCTIONAL, OPERATING PROPERLY AND WHAT CORRECTIVE ACTIONS HAVE BEEN TAKEN.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
Resolution: MI's attended. Received causal analysis and technical report. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2019 Resolved
Missing insulation on Engine Room hatch port side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Insulation replaced all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019 Resolved
Emergency light port and starboard side held in place with zip ties. Mount emergency light properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Emergency lights on Port and STBD side engine rooms installed properly.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 23 November 2019 Resolved
Cracked welded spacers in forepeak tank need welded.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Spacers properly welded in forepeak tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2019 Resolved
Water pump had exposed wires. Enclose wire to fresh water pump in wateright enclosure.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Wires for water pump were placed inside an enclosure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 November 2019 Resolved
Exhaust leak on port generator. Investigate cause and make permenent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: MI witnessed operation of port generator, no exhaust leaks visible, All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019 Resolved
Batteries on port engine room missing fill caps. Replace caps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Cleared all SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 November 2019 Resolved
Broken hand rail port side aft. Re-weld to satisfaction of Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 19 August 2020
Resolution: Hand rail repair completed satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019 Resolved
Light cover in engine room port side was zipped tied. Repair or replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Light cover replaced all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019 Resolved
Axe was laying on deck. Permenently mount fire axe.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Fire Axe permanently mounted all SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2019 Resolved
Vessel has unknown hydraulic leak in lazerette from steering gear. Diagnose failure and make repairs to system components.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: attending MI witnessed operational test of steering system, no leaks at the time of inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019 Resolved
Broken mounts at bottom of ladder port side aft compartment. Reweld to secure ladder to reduce crew hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Cleared all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019 Resolved
Light fixture in life jacket locker on main deck has exposed wires and no cover. Remove or replace light fixture.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Light fixture in life jacket locker permanently removed, All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 September 2019 Resolved
Vessels fire detection system was found in inoperable condition. Vessel must return system to operational service prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Resolution: Conducted satisfactory test of fire detection system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 September 2019 Resolved
Vessels fire suppression system was found to have expired servicing. Vessel must have fire suppression serviced and tested prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Resolution: Vessel provided current servicing records.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2019 Resolved
All vessel spaces where found to have excessive water in the bilge. Vessel was unable to determine where water was coming from. Vessel must clean bilges and investigate source of water ingress. prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Resolution: Vessel bilge cleaned of excessive amounts of water.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 September 2019 Resolved
Vessels air conditioning system was found to not maintain fire boundaries. Vessel must maintain fire boundaries. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 6 November 2018 Resolved
Vsl is broadcasting incorrect Name, Vsl is not broadcasting dimension information (AIS Antenna Position ABCD values equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 August 2020
Resolution: Data inputs entered and broadcasting appropriately.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 14 July 2017 Resolved
Engine had low power.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: Sea trials successfully completed.
Engineering › Generator (propulsion-electric) › Circuit Board
Issued 8 September 2015 Resolved
Gauges for generator were not functional at operating station as per requirement 46CFR 119.410
Due 22 September 2015
Resolved 30 September 2015
Resolution: Received email notification attesting to the repairs to the INOP gauges; picture of operational gauge included. Gauges for generator have been repaired and are functional at operating station. All SAT
Construction/Loadline › Hull › Hull Plating
Issued 8 September 2015 Resolved
Provide repair proposal for pitting in Portside Crash compartment.
Due 22 September 2015
Resolved 23 October 2015
Resolution: Received email (w/pictures) attesting to the repairs of the pitting in Portside Crash compartment. Vessel master utilized local welder to complete the repairs. ALL SAT. Note: Repair proposal was received and approved by this office prior to hull repairs.
Engineering › Fuel Oil Service System › Hose
Issued 19 August 2014 Resolved
Fuel lines must be protected from mechanical injury. Place chaffing gear at points where the fuel lines make contact with the vessel and its machinery.
Condition: Improper Installation
Due 2 September 2014
Resolved 2 September 2014
Resolution: Attended vessel and cleared above deficiency.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 19 August 2014 Resolved
A suitable hull strainer must be installed in the raw water intake. Clean/ replace the filter.
Condition: Improper/Lack of Maintenance
Due 2 September 2014
Resolved 2 September 2014
Resolution: Attended vessel and cleared above deficiency.
Engineering › Fuel Oil Service System › Filter
Issued 19 August 2014 Resolved
A suitable marine type strainer must be fitted in the fuel supply line. Replace dirty fuel filter.
Condition: Improper/Lack of Maintenance
Due 2 September 2014
Resolved 2 September 2014
Resolution: Attended vessel and cleared above deficiency.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 19 August 2014 Resolved
Replace extinguished pre-engineered fix gas fire extinguishing system. (1100 cubic foot FE-241)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2014
Resolution: Bottle was replaced and installed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 August 2014 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with its certificate of inspection giving consideration to guards in hazardous places. Install a guard to prevent the accidental discharge of fire equipment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2014
Resolution: A plastic tie was placed on the pull station''s pin. An additional guard will be installed.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 19 August 2014 Resolved
A-Class bulk heads must be so installed with approved structural insulation. Repair or replace areas in the engine room where there is missing or damaged insulation.
Condition: Damaged By Earlier Event
Due 2 September 2014
Resolved 2 September 2014
Resolution: Attended vessel and cleared above deficiency.
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 May 2012 Resolved
Coast Pilot missing, obtain a current edition and maintain o/b the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Current edition of the Coast Pilot obtained & maintained o/b the vessel.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 May 2012 Resolved
Proof of enrollment in a drug consortium missing, provide current list as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Proof of enrollment into a drug consortium provided to the CG marine inspector.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 May 2012 Resolved
Reflective tape on 3 ring buoys not SOLAS approved reflective tape. Replace with SOLAS approved reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: SOLAS reflective tape applied to all 3 life rings.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2012 Resolved
Machinery guards for port & starboard side generators missing, provide as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2012
Resolved 31 May 2012
Resolution: Machinery guards installed over the belts on both generators.
Engineering › Bilge Water Management System › Strainer
Issued 9 May 2012 Resolved
Strainers missing from bilge pick-up in starboard side sewage tank compt and port side lazarette. Replace as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2012
Resolved 28 May 2012
Resolution: Strainers placed over the bilge pick-ups in the starbaord side sewage tank compartment & port side lazarette.
Engineering › Fuel Oil Service System › Filter
Issued 9 May 2012 Resolved
Diesel fuel in the Raycor Filter Bowls in the starboard side engine room. Remove diesel fuel as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Diesel fuel removed from the Raycor Filter bowls.
Engineering › Feedwater/Condensate Water System › Tank
Issued 9 May 2012 Resolved
Leak on coolant tank on the starboard side generator. Make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 May 2012
Resolved 16 May 2012
Resolution: Coolant tank repaired to the satisfaction of the CG marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 May 2012 Resolved
Starboard side generator didn't secure when the leads for the Fire Boy were disconnected. Make permanent repairs to ensure that the starboard generator secures when the leads to the Fire Boy are disconnected.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Starboard side generator secured when the FireBoy was activated to the satisfaction of the CG marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 May 2012 Resolved
Port side main engine and generator didn't secure when the leads for the Fire Boy were disconnected. Make permanent repairs to ensure that the port side main engine and generator secures when the leads to the Fire Boy are disconnected.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: Port side main engine & generator secured when the FireBoy was activated to the satisfaction of the CG marine inspector.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 9 May 2012 Resolved
Mineral spirits and paints inproperly stored in the fuel tank comptarment. Remove all flammable material from space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2012
Resolution: All flammable material removed from the fuel tank compartment.
Engineering › Bilge Water Management System › Strainer
Issued 16 March 2010 Resolved
Strainer on bilge suction lines in starboard engine room and space aft of engine room missing or broken, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2010
Resolved 15 April 2010
Resolution: Strainer on bilge suction lines replaced as new.
Engineering › Fuel Oil Service System › Valve
Issued 16 March 2010 Resolved
Fuel shut-off handles at starboard side fuel tanks severally corroded, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2010
Resolved 15 April 2010
Resolution: Fuel shut-off valves replaced as new.
Stability › Weathertight Integrity › General
Issued 16 March 2010 Resolved
Three (3) inch coaming missing from underneath door on main deck aft, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 April 2010
Resolved 15 April 2010
Resolution: Three inch coaming added to main deck door aft.
Personnel › Training › First Aid/CPR
Issued 23 February 2010 Resolved
Provide proof of First Aid/CPR training
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 16 March 2010
Resolution: Proof of First Aid/CPR training presented to the CG Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 23 February 2010 Resolved
Provide proof of enrollment in Drug and Alcohol Program for all crew.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 16 March 2010
Resolution: Proof of Drug & Alcohol Program enrollment presented to the CG Marine Inspector.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 February 2010 Resolved
Provide navigation publications for the area of operations.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 16 March 2010
Resolution: Proper navigation pubs presented to the CG Marine Inspector.
Stability › Weathertight Integrity › General
Issued 23 February 2010 Resolved
Repair/Replace cracked window in Pilothouse
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 24 February 2010
Resolution: Window was replaced.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 23 February 2010 Resolved
Provide Compass Deviation Table
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 16 March 2010
Resolution: Compass Deviation Table presented to the CG Marine Inspector.
Construction/Loadline › Structures › Door
Issued 23 February 2010 Resolved
Repair/Replace door handle on Pilothouse door.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 23 February 2010
Resolution: Door handle was replaced.
Fire Fighting › Nozzles › Number
Issued 23 February 2010 Resolved
Provide required number of fire nozzles.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 24 February 2010
Resolution: Verified proper number of fire nozzles.
Fire Fighting › Fire Hydrants › Condition
Issued 23 February 2010 Resolved
Spanner wrench is missing for each Fire Hydrant.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 16 March 2010
Resolution: Spanner wrench purchased & o/b for the fire hydrant.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 February 2010 Resolved
Line was not properly attached to Ring Buoy.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 24 March 2010
Resolution: Verfied proper arrangement for Ring Buoy and attached line.
Engineering › Steering Gear System › Ram
Issued 23 February 2010 Resolved
Stbd Tiller Steering arm is loose (bolt).
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 24 February 2010
Resolution: Bolt was tightened and thread locked to keep from coming loose.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 23 February 2010 Resolved
Port tank room upper wire run. Remove foam and replace with fire stop or other suitable material.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 16 March 2010
Resolution: Fire stop installed in the port tank room upper wire run.
Construction/Loadline › Penetrations › Valve Flange
Issued 23 February 2010 Resolved
Cap off discharge line in Port storage room.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 24 February 2010
Resolution: Verified proper cap on discharge line.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 23 February 2010 Resolved
Remove oil from Port Sewage Tank Space.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 24 February 2010
Resolution: Oil was removed from space.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 23 February 2010 Resolved
Stbd Sewage tank has a leak from piping coming out the top.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 24 February 2010
Resolution: Piping was tightened and the leaking was mitigated.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 February 2010 Resolved
E/R panel boards were not provided with drip shields. Seal all cable penetrations IWO E/R electrical panel tops and provide gasket IWO of panel.
Action required: 705 - Other - as specified
Due 23 March 2010
Resolved 16 March 2010
Resolution: Drip shields installed under panel boards. All cable penetrations sealed.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 February 2010 Resolved
Drills need to be conducted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2010
Resolved 16 March 2010
Resolution: Drills conducted to the satisfaction of the CG Marine Inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 October 2008 Resolved
Replace/repair broken e-light fixture in starboard engineroom.
Due 5 November 2008
Resolved 12 November 2008
Documentation › Markings/Placards › Official Number (US)
Issued 22 October 2008 Resolved
Permanently mark official number
Due 5 November 2008
Resolved 12 November 2008
Construction/Loadline › Hull › Weld
Issued 11 April 2008 Resolved
In the most forward compartment overhead between frames 2 and 3 several of the longitudinal brackets have broken away from their welds, two spacer blocks between overhead frame #2 and the lower frame #2. The stbd sewage tank appears to have a crack iwo forward outboard bracket weld and appears to be leaking sewage. The inboard fwd bracket weld at the frame is also broken.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2008
Resolved 21 May 2008
Resolution: Completed final walk through of vessel all items noted for repair have been repaired satisfactorily.
Fire Fighting › Fire Hoses › Condition
Issued 30 June 2006 Resolved
Replace port side fire hose, hose is dripping and showing signs of dry rot.
Condition: Improper/Lack of Maintenance
Due 10 July 2006
Resolved 1 August 2006
Fire Fighting › Fire Main › Condition
Issued 30 June 2006 Resolved
Secure/repair small leak on starboard fire main, leak below hydrant on and piping next to fire pump.
Condition: Improper/Lack of Maintenance
Due 10 July 2006
Resolved 30 June 2006
Lifesaving › Lifebuoys › Serviceable
Issued 30 June 2006 Resolved
Replace worn clip with non-corrosive clip on life ring located next to pilot house.
Condition: Improper Installation
Due 10 July 2006
Resolved 1 August 2006
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 30 June 2006 Resolved
Replace anchor that was removed during drydock.
Condition: Unknown
Due 5 July 2006
Resolved 1 August 2006
Deck/Cargo › Mooring/Anchoring › Winch
Issued 6 June 2006 Resolved
Port side anchor windlass winch has hose clamps. Install new hydraulic hose with appropriate hydraulic fittings.
Condition: Improper/Lack of Maintenance
Due 31 July 2006
Resolved 28 August 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 June 2005 Resolved
COI was missing from vessle
Condition: Improper/Lack of Maintenance
Due 22 July 2005
Resolved 28 July 2005
Resolution: posted COI
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 22 June 2005 Resolved
Vessel did not have a licensed mate or Senior deckhand designated in writing.
Condition: Improper/Lack of Maintenance
Due 22 July 2005
Resolved 31 October 2005
Resolution: Vessel reduced from Sub K to T. Deckhand not required.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 22 June 2005 Resolved
Repair or remove single sideband radio on bridge
Condition: Unknown
Due 22 July 2005
Resolved 28 July 2005
Resolution: Radio is operable.
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 June 2005 Resolved
Provide proper donning placard for PFD's on board
Condition: Improper Installation
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected
Communications › Radio Communications › EPIRB
Issued 22 June 2005 Resolved
Replace Hydrostatic release on EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2005
Resolved 22 July 2005
Resolution: corrected.
Communications › Radio Communications › EPIRB
Issued 22 June 2005 Resolved
Provide proof of NOAA registration for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 June 2005 Resolved
Replace rubber trashcans with non-combustible trashcans.
Condition: Improper Installation
Due 22 July 2005
Resolved 31 October 2005
Communications › Alarms/Indicators › Fire Alarm
Issued 22 June 2005 Resolved
Replace locks on fire alarm boxes and remove tape.
Condition: Improper Installation
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected and tested.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 22 June 2005 Resolved
retain voyage plan listing passengers for all Oceans voyages.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 28 July 2005
Resolution: corrected.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 June 2005 Resolved
Secure ladders in Engine room to deck.
Condition: Improper/Lack of Maintenance
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected
Engineering › Lubricating Oil Service System › Hose
Issued 22 June 2005 Resolved
Repair leaking hydraulic hoses on Port and Stbd generators.
Condition: Improper/Lack of Maintenance
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 June 2005 Resolved
Remove hooks from engine room doors and install method for egress out of engine room.
Condition: Improper Installation
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected.
Construction/Loadline › Structures › Door
Issued 22 June 2005 Resolved
Make Aft door threshold watertight.
Condition: Improper Installation
Due 22 August 2005
Resolved 29 June 2006
Resolution: Installed threshold cover plate
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 June 2005 Resolved
Mark all emergency lighting.
Condition: Improper Installation
Due 22 July 2005
Resolved 31 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 22 June 2005 Resolved
Replace wasted lighting fixture covers on STBD side of main deck.
Condition: Improper/Lack of Maintenance
Due 22 July 2005
Resolved 31 October 2005
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 22 June 2005 Resolved
Repair cracked welds on stbd aft rail door.
Condition: Improper/Lack of Maintenance
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 22 June 2005 Resolved
Repair broken windows on stbd side of main deck.
Condition: Damaged By Earlier Event
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 22 June 2005 Resolved
Install portable lighting at operating station and enterence to both engine rooms.
Condition: Improper Installation
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 22 June 2005 Resolved
Replace aft port mooring line and provide better mooring arrangement for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 July 2005
Resolution: corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 June 2005 Resolved
Repack thru-hull fittings for both remote fuel shutoffs in stbd and port engine rooms.
Condition: Improper/Lack of Maintenance
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected
Documentation › Markings/Placards › Official Number (US)
Issued 22 June 2005 Resolved
Change homeport port on stern to reflect documentation certificate.
Condition: Improper Installation
Due 22 July 2005
Resolved 28 July 2005
Resolution: corrected.
Construction/Loadline › Hull › Hull Plating
Issued 31 December 2004 Resolved
Discontinue use of vsl until it can be dry-docked to affect repairs. Vsl has cracks in the bottom plate iwo the rudder space.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 January 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 November 2004 Resolved
Weld cracks in the following seat backs: main cabin seats 1-3 & 5-6, upper cabin seat 5.
Condition: Improper Installation
Due 6 December 2004
Resolved 6 December 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 November 2004 Resolved
Re-install the deck coaming for the aft cabin door.
Condition: Placed in Improper Service
Due 6 December 2004
Resolved 6 December 2004
Engineering › Sea-water System (primary cooling) › Valve
Issued 30 November 2004 Resolved
Replace the PVC plug in the non-use through hull vlv in the stbd eng rm with a brass one.
Condition: Placed in Improper Service
Due 6 December 2004
Resolved 6 December 2004
Accommodation/Occupational Safety › Washroom/Toilet
Issued 26 August 2003 Resolved
Install shower for crew's use. Vessel restricted from voyages exceeding 12 hours in any 24 hour period until completed. LEGACY COMPONENT DESC: Shower/Bathtub
Due 26 August 2003
Resolved 29 August 2003
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 26 August 2003 Resolved
Install 3 berths for crew's use. Vessel restricted from voyages exceeding 12 hours in any 24 hour period until completed. LEGACY COMPONENT DESC: Berth
Due 26 August 2003
Resolved 29 August 2003
Construction/Loadline › Hull
Issued 3 June 2003 Resolved
C/R bottom plate in way of port/stbd rudders (area repaired pursuant to LeMole Naval Architecture letter dated 30May03). Vessel restricted to rivers route no more than 1 mile from shore with passengers until corrected. LEGACY COMPONENT DESC: Bottom Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2003
Resolved 27 June 2003
Resolution: Rcvd e-mail photographs follwing repairs & dye penetrant testing from [name withheld] (Derecktor Shipyard).
Fire Fighting › Ventilation Systems
Issued 14 May 2003 Resolved
Prove proper operation of port/stbd engineroom ventilation closures. LEGACY COMPONENT DESC: Ducts
Due 21 May 2003
Resolved 21 May 2003
Operations/Management
Issued 14 May 2003 Resolved
Provide copy of U.S. Coast Guard approved or examined plans to [name withheld] (those listed at 46 CFR 116.202). Vessel restricted to carrying no more than 150 passengers until completed & as built verification completed by [name withheld] marine inspector.
Due 14 May 2003
Resolved 29 May 2003
Engineering › Bilge Water Management System
Issued 14 May 2003 Resolved
Replace broken handles to port & stbd screw down bilge suction valves in #2 compartment. LEGACY COMPONENT DESC: Valve
Due 21 May 2003
Resolved 21 May 2003
Documentation › Safety/Response Plans/Programs
Issued 14 May 2003 Resolved
Provide copy of fire control plan to [name withheld] & post on vessel in a location that is visible & accessible to all passengers in accordance with 46 CFR 116.530. Vsl restricted to carrying no more than 150 passengers until completed & as built verification completed by [name withheld] marine inspector. LEGACY COMPONENT DESC: Fire Control Plans
Due 14 May 2003
Resolved 29 May 2003
Construction/Loadline › Hull
Issued 14 May 2003 Resolved
Properly weld 2 stiffeners stbd/1 stiffener port to collision bulkhead in compartment #2. LEGACY COMPONENT DESC: Stiffener
Due 21 May 2003
Resolved 21 May 2003
Fire Fighting › Fire Pumps
Issued 14 May 2003 Resolved
Replace cracked fire pump pressure gauge (port). LEGACY COMPONENT DESC: Pressure
Due 21 May 2003
Resolved 21 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 14 May 2003 Resolved
Smooth edges to compartment hatches.
Due 21 May 2003
Resolved 21 May 2003
Electrical › Electrical Distribution System (service)
Issued 14 May 2003 Resolved
Install non-conductive electrical matting IWO main distribution panel. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Due 21 May 2003
Resolved 21 May 2003
Construction/Loadline › Hull
Issued 14 May 2003 Resolved
Weld frame #4 to sideshell long #1 in bay 4 of compartment #3, outboard side. LEGACY COMPONENT DESC: Transverse Frame
Due 21 May 2003
Resolved 21 May 2003
Operations/Management › Drills/Instruction
Issued 5 May 2003 Resolved
Perform drills to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Due 5 May 2003
Resolved 14 May 2003
Engineering › Steering Gear System
Issued 5 May 2003 Resolved
Address leak to stbd hydraulic line. LEGACY COMPONENT DESC: Hydraulic line
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2003
Resolved 14 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 5 May 2003 Resolved
Place portable light at operating station. LEGACY COMPONENT DESC: Portable lighting
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Documentation › Certificates/Documents
Issued 5 May 2003 Resolved
Update marine operator's permit. LEGACY COMPONENT DESC: Marine Operators Permit
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Electrical › Electric Supply System (service)
Issued 5 May 2003 Resolved
Install grommets as needed IWO port side support (fwd). LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 21 May 2003
Navigation › Collision/Grounding Avoidance
Issued 5 May 2003 Resolved
Paint navigation light screens flat black. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 5 May 2003 Resolved
Anchor all ceiling straps for drop ceiling. LEGACY COMPONENT DESC: Drop ceiling
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 5 May 2003 Resolved
Install 30 x 30 mesh on fuel vents. LEGACY COMPONENT DESC: Vent Pipe Flame Screen
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2003
Resolved 21 May 2003
Construction/Loadline › Structures
Issued 5 May 2003 Resolved
Address rough edges as needed. LEGACY COMPONENT DESC: Frames/supports throughout
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 5 May 2003 Resolved
Provide proper securing devices for hatches (when in open position). LEGACY COMPONENT DESC: Hatch securing device
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Pollution Prevention/Response › Prevention Equipment
Issued 5 May 2003 Resolved
Provide plugs for containment box at fuel fills. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Electrical › Electric Supply System (service)
Issued 5 May 2003 Resolved
Address/ensure wires are properly bracketed. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 5 May 2003 Resolved
Ensure bilge spaces are properly cleaned. LEGACY COMPONENT DESC: General housekeeping
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Deck/Cargo › Mooring/Anchoring
Issued 5 May 2003 Resolved
Properly secure anchor line ensuring there is chain. LEGACY COMPONENT DESC: Anchor Rope
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 14 May 2003
Fire Fighting › Miscellaneous Items
Issued 5 May 2003 Resolved
Provide fire stops for stbd fuel tank space. LEGACY COMPONENT DESC: Fire stops
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 21 May 2003

Casualty record · 4

16 February 2005Routine · role: Involved in a Marine Casualty · activity 2318596
4 November 2006Routine · role: Involved in a Marine Casualty · activity 2817114
30 March 2011Routine · role: Involved in a Marine Casualty · activity 3976502
14 April 2012Routine · role: Involved in a Marine Casualty · activity 4299257
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SWIFT CAT (2005–2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.