Inspection history · 13
31 August 2020
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7046479
25 August 2020
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7042594
10 December 2019
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6871310
26 November 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6863001
23 November 2019
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6862367
25 September 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6820002
3 September 2019
Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6802812
6 November 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6575236
26 June 2018
Deadweight Survey · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6465180
20 September 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6269417
14 July 2017
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6209131
7 July 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6200861
7 September 2016
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6005718
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 12 December 2019
Resolved
A fan cover within an the duct was obstructing the operation of the starboard side engine room air damper. Re-secure fan cover.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: Fan cover removed, witnessed operation of dampener, All SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 December 2019
Resolved
A puddle of oil was found under the port side generator. Determine the source of the oil and repair as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 19 August 2020
Resolution: Satisfactory repairs to generator completed and all oil removed below. SAT OPTEST completed of generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 12 December 2019
Resolved
Upon starting the starboard side generator, exhaust became present in the space. Determine the source of the exhaust and repair as necessary
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: MI witnessed operation of STBD generator, no exhaust leaks visible, All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2019
Resolved
A wire splice aft of the starboard side steering gear was not in a junction box; This work occurred after the 23 Nov inspection. Place wire splice in an appropriate junction box.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: All wires placed inside junction box, All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 December 2019
Resolved
The base of the rudder post bearing of starboard rudder was fractured. Repair or replace bearing as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: STBD side rudder bearing replaced satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 12 December 2019
Resolved
Port side generator missing machinery guard. Install machinery guard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2019
Resolved 16 March 2020
Resolution: Machinery guard on Port generator installed satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 November 2019
Resolved
VESSEL REPORTED CASUALTY TO #1 GENERATOR.
SUBMIT WRITTEN AND SIGNED CAUSAL ANALYSIS.
SUBMIT TECHNICAL REPORT STATING THAT GENERATOR IS FULLY FUNCTIONAL, OPERATING PROPERLY AND WHAT CORRECTIVE ACTIONS HAVE BEEN TAKEN.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
Resolution: MI's attended. Received causal analysis and technical report. All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2019
Resolved
Missing insulation on Engine Room hatch port side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Insulation replaced all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
Emergency light port and starboard side held in place with zip ties. Mount emergency light properly.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Emergency lights on Port and STBD side engine rooms installed properly.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 23 November 2019
Resolved
Cracked welded spacers in forepeak tank need welded.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Spacers properly welded in forepeak tank.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 November 2019
Resolved
Water pump had exposed wires. Enclose wire to fresh water pump in wateright enclosure.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Wires for water pump were placed inside an enclosure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 November 2019
Resolved
Exhaust leak on port generator. Investigate cause and make permenent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: MI witnessed operation of port generator, no exhaust leaks visible, All SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
Batteries on port engine room missing fill caps. Replace caps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Cleared all SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 November 2019
Resolved
Broken hand rail port side aft. Re-weld to satisfaction of Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 19 August 2020
Resolution: Hand rail repair completed satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
Light cover in engine room port side was zipped tied. Repair or replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Light cover replaced all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
Axe was laying on deck. Permenently mount fire axe.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Fire Axe permanently mounted all SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 November 2019
Resolved
Vessel has unknown hydraulic leak in lazerette from steering gear. Diagnose failure and make repairs to system components.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: attending MI witnessed operational test of steering system, no leaks at the time of inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
Broken mounts at bottom of ladder port side aft compartment. Reweld to secure ladder to reduce crew hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Cleared all SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 November 2019
Resolved
Light fixture in life jacket locker on main deck has exposed wires and no cover. Remove or replace light fixture.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2019
Resolved 16 March 2020
Resolution: Light fixture in life jacket locker permanently removed, All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 September 2019
Resolved
Vessels fire detection system was found in inoperable condition. Vessel must return system to operational service prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Resolution: Conducted satisfactory test of fire detection system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 September 2019
Resolved
Vessels fire suppression system was found to have expired servicing. Vessel must have fire suppression serviced and tested prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Resolution: Vessel provided current servicing records.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 September 2019
Resolved
All vessel spaces where found to have excessive water in the bilge. Vessel was unable to determine where water was coming from. Vessel must clean bilges and investigate source of water ingress. prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
Resolution: Vessel bilge cleaned of excessive amounts of water.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 September 2019
Resolved
Vessels air conditioning system was found to not maintain fire boundaries. Vessel must maintain fire boundaries. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 6 November 2018
Resolved
Vsl is broadcasting incorrect Name, Vsl is not broadcasting dimension information (AIS Antenna Position ABCD values equals 0) and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 August 2020
Resolution: Data inputs entered and broadcasting appropriately.
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 14 July 2017
Resolved
Engine had low power.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2017
Resolution: Sea trials successfully completed.