MAURY USCG vessel records
← All vessels

STRETCH DUCK 25

STRETCH DUCK 25 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2016, most recently in August 2019, along with 4 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2019. Most recent: inspection, 19 August 2019.

Built
1945
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

589754
Flag
UNITED STATES
Maury page id
psix-589754

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

19 August 2019 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788039
25 June 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6760721
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622662
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519689
23 May 2018 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6422392
23 May 2018 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6422796
3 January 2018 Hull Examination · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6331920
14 February 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6090463
4 January 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5790700

Deficiency record · 4

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 February 2019 No resolution recorded
Demonstrate compliance with new Conditions of Operation listed on amended COI.
Action required: 17 - Rectify deficiencies prior to departure
Stability › Incline Test › General
Issued 24 January 2018 Resolved
Provide proof that the vessel is in compliance with the issued Stability Letter by means of weigh tickets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 23 February 2018
Resolution: Received weigh ticket for the Duck. Vsl weight within 2% of the parent hull weight.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2018 Resolved
Provide the OCMI a list of approved plans to which the vessel is constructed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 23 February 2018
Resolution: Received a list of plans the Duck is constructed to.
Construction/Loadline › Hull › Weld
Issued 8 March 2017 Resolved
Prove repair of small leak in hull at steering box mounting penetration.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2017
Resolution: Fractured weld repaired and Duck was float tested in Table Rock with no leaks detected.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.