MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 25

STRETCH DUCK 25 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 2002, most recently in August 2019, along with 42 deficiencies — 1 with no resolution recorded —.

Records from 2002 to 2019. Most recent: inspection, 19 August 2019.

Built
1945
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

589754
Flag
UNITED STATES
—
Maury page id
psix-589754

Inspections, by type

…with no type recorded3
Years with a record 14 calendar years (2002–2019)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

DUKW 34 Passenger (Inspected) · MISLE 626513 · 24 July 2009 · activity 3547659

Inspection history · 28

19 August 2019 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788039
25 June 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6760721
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622662
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519689
23 May 2018 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6422392
23 May 2018 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6422796
3 January 2018 Hull Examination · Administrative Inspection · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6331920
14 February 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6090463
4 January 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5790700
11 July 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4376697
9 August 2011 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4112449
19 January 2011 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3928899
8 September 2010 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3845387
29 July 2009 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3549316
24 July 2009 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3547659
29 October 2008 Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3353647
11 January 2008 Annual Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3128652
8 February 2007 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2868947
24 October 2005 Administrative Inspection
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 2521065
6 September 2005 Examination of Repairs · Annual Inspection · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2522809
1 April 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2367108
13 September 2004 Simplified Stability Test
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2194485
18 March 2004 Construction Oversight · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2040868
27 September 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1924951
22 May 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1799065
27 January 2003 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1737669
12 December 2002 Initial Construction-Excluding Oversight · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1714183
21 August 2002 Construction Oversight · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1664207

Deficiency record · 42

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 February 2019 No resolution recorded
Demonstrate compliance with new Conditions of Operation listed on amended COI.
Action required: 17 - Rectify deficiencies prior to departure
Stability › Incline Test › General
Issued 24 January 2018 Resolved
Provide proof that the vessel is in compliance with the issued Stability Letter by means of weigh tickets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 23 February 2018
Resolution: Received weigh ticket for the Duck. Vsl weight within 2% of the parent hull weight.
Construction/Loadline › Hull › Hull Plating
Issued 24 January 2018 Resolved
Provide the OCMI a list of approved plans to which the vessel is constructed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 23 February 2018
Resolution: Received a list of plans the Duck is constructed to.
Construction/Loadline › Hull › Weld
Issued 8 March 2017 Resolved
Prove repair of small leak in hull at steering box mounting penetration.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2017
Resolution: Fractured weld repaired and Duck was float tested in Table Rock with no leaks detected.
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2011 Resolved
Submit repair proposal for hole in transom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2011
Resolution: Witnessed satisfactory repairs.
Engineering › Fuel Oil Service System › Tank
Issued 19 January 2011 Resolved
Prove fitness of fuel sending unit which was found wet with fuel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2011
Resolution: Witnessed repair of sending unit seal.
Engineering › Steering Gear System › Pump
Issued 19 January 2011 Resolved
Repair or Replace loose/leaking power steering pump reservoir cap.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2011
Resolution: Witnessed satisfactory fitting cap.
Engineering › Lubricating Oil Service System › Hose
Issued 19 January 2011 Resolved
Prove fitness/compliance w/46 CFR 182.720(e) (flexible non-metallic hose) for remote oil filter hose found wet w/ oil.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2011
Resolution: Hose determined to meet SAE J-1942. New hose installed sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 September 2010 Resolved
Label aft life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2011
Resolution: Witnessed labeled life ring.
Construction/Loadline › Hull › Hull Plating
Issued 8 September 2010 Resolved
Provide repair proposal for possible crack, stbd side shell, two frames fwd of transom and/or clean for reinspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2011
Resolution: Witnessed satisfactory repair.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 July 2009 Resolved
Repair prop engager.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2009
Resolution: Witnessed test of new part, all sat.
Construction/Loadline › Hull › Hull Plating
Issued 29 October 2008 Resolved
Prove proper repairs to stern tube.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2009
Resolution: Witnessed satisfactory repairs.
Electrical › Electric Supply System (service) › Battery Installation
Issued 26 February 2008 Resolved
Install cover over aft battery fuse
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2008
Resolution: Witnessed new cover installed over the aft battery main fuse, all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 26 February 2008 Resolved
Prove proper service of BII portable extinguisher
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2008
Resolution: New portable and properly serviced BII extinguisher had been purchased and placed on the vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 February 2008 Resolved
Conduct MOB and Fire Drill
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 March 2008
Resolution: Witnessed satisfactory performance of drills
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 February 2007 Resolved
Conduct drills
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 March 2007
Resolution: Witnessed satisfactory drills on DUKW 51.
Communications › Alarms/Indicators › Fire Alarm
Issued 8 February 2007 Resolved
Prove compliance with fire detection regulations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Resolution: Determined to be sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 February 2007 Resolved
Prove compliance with 182.460(d) and 181.410 (b)(10) regarding auto shut down of blower.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2007
Resolution: Inspected sat
Lifesaving › Hand Flares › Not on Board
Issued 8 February 2007 Resolved
Provide missing safety kit. (Safety outfit not onboard due to moving maintenance locations).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2007
Resolution: Inspected sat.
Construction/Loadline › Hull › Hull Plating
Issued 6 September 2005 Resolved
Found 3" crack in port fwd wheel well.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2005
Resolved 28 June 2006
Resolution: Underway test sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2005 Resolved
Prove proper operation of Nav lights.
Action required: 705 - Other - as specified
Due 28 July 2006
Resolved 19 January 2007
Resolution: Rewired lights, all sat.
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 September 2005 Resolved
Provide PFD donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2006
Resolved 19 January 2007
Resolution: Installed placard, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 6 September 2005 Resolved
Provide O-ring for CO2 system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2006
Resolved 19 January 2007
Resolution: Installed gasket, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 6 September 2005 Resolved
Prove proper operation of CO2 shutdown system.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 8 February 2007
Resolution: Deficiency administratively cleared and re-issued in a seperate activity.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 6 September 2005 Resolved
Conduct curtain drop test.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 19 January 2007
Resolution: Tested sat.
Engineering › Gasoline Engine (propulsion) › Backfire Flame Control
Issued 6 September 2005 Resolved
Provide approved flame arrestor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2006
Resolved 19 January 2007
Resolution: Witnessed new approved flame arrestor.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 6 September 2005 Resolved
Provide proper connection of anchor rode.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 19 January 2007
Resolution: Witnessed new line properly spliced.
Construction/Loadline › Hull › Girder
Issued 6 September 2005 Resolved
Provide repair proposal for RF wheel well leak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2006
Resolved 19 January 2007
Resolution: Repair tested sat.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 1 April 2005 Resolved
Provide proper marpol, oil discharge and emergency broadcast placards as needed.
Due 1 May 2005
Resolved 20 April 2005
Resolution: Provided placards.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 1 April 2005 Resolved
Provide proper way to discharge anchor.
Due 1 May 2005
Resolved 20 April 2005
Resolution: Provided way.
Electrical › Electrical Distribution System (service) › Cable
Issued 1 April 2005 Resolved
Properly secure wiring in way of the dash.
Due 1 May 2005
Resolved 20 April 2005
Resolution: Wiring secured.
Accommodation/Occupational Safety › Medical/First Aid
Issued 18 March 2004 Resolved
Provide blanket for Man Overboard. LEGACY COMPONENT DESC: Medicine Chest
Due 24 April 2004
Resolved 19 April 2004
Resolution: Provided blanket.
Construction/Loadline › Structures
Issued 18 March 2004 Resolved
Fix pulls on floor boards.
Condition: Design Flaw
Due 24 April 2004
Resolved 19 April 2004
Resolution: Fixed pulls.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 March 2004 Resolved
Provide latches for jump seat.
Condition: Improper Installation
Due 24 April 2004
Resolved 19 April 2004
Resolution: Provided latch.
Engineering › Fuel Oil Storage/Transfer System
Issued 18 March 2004 Resolved
Stow fuel line a safe distance from shaft. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 24 April 2004
Resolved 19 April 2004
Resolution: Stowed hose.
Engineering › Freshwater System (jacketwater cooling)
Issued 18 March 2004 Resolved
Fix brackets on keel coolers.
Condition: Improper Installation
Due 24 April 2004
Resolved 19 April 2004
Resolution: Fixed brackets.
Navigation
Issued 22 May 2003 Resolved
Provide an VHF radio, FCC Station Certificate, Radio Safety Certificate and Operators Permit.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided documents.
Deck/Cargo › Mooring/Anchoring
Issued 22 May 2003 Resolved
Provide an easily deployable anchoring system.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided anchor.
Operations/Management
Issued 22 May 2003 Resolved
Provide state registration for this vessel.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided state registration.
Operations/Management
Issued 22 May 2003 Resolved
Provide a specific stability letter for this vessel.
Due 23 June 2003
Resolved 23 June 2003
Resolution: Provided stability letter.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 27 January 2003 Resolved
Properly label all PFD's and Liferings with vessel's name.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2004
Stability › Watertight Integrity
Issued 12 December 2002 Resolved
Make proper repairs to hull plating by propeller shaft through hull tube, port side shell plating by steering box, and starboard side shell by frame rail across from starboard header. LEGACY COMPONENT DESC: Hull
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 December 2002
Resolved 27 January 2003

Ownership record