MAURY USCG vessel records
← All vessels

GOLDENEYE

GOLDENEYE is a 2002 freight ship. The Coast Guard has recorded 4 inspections since 2016, most recently in July 2018, along with 3 deficiencies.

Records from 2016 to 2018. Most recent: inspection, 19 July 2018.

Built
2002
Last inspected
19 July 2018
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 July 2018
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9244855
589809
Flag
MARSHALL ISLANDS
Maury page id
psix-589809

Documentation record

Tonnage as PSIX records it30053 - Convention (Subpart B), Gross Ton
18207 - Convention (Subpart B), Net Ton
52420 - Dead Weight, Ton
60771 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

4 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

19 July 2018 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6484638
17 July 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6482083
12 December 2017 ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6321157
19 September 2016 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5996967

Deficiency record · 3

14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 17 July 2018 Resolved
14608 - Incinerator incl. operations and operating manual - Each incinerator on a ship constructed on or after 01JAN2000 shall meet the requirements contained in appendix IV taking into account standards specification for shipboard incinerators developed by the organization. PSCO noted installed incinerator interlock to prevent ash removal doors from opening while burning is in progress was found inoperable but rectified on the spot. - MARPOL VI/16.6.1 & MEPC 76(40)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 July 2018
Resolved 17 July 2018
Resolution: Crew removed and cleaned the electrical sensor and reinstalled the sensor. The interlock is now operational.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 17 July 2018 Resolved
14608 - Incinerator incl. operations and operating manual - Each incinerator on a ship constructed on or after 01JAN2000 shall meet the requirements contained in appendix IV. Incinerator walls are to be protected with refractory. PSCO noted incenerator refractory material was broken/missing and unable to prevent outside surface temperature of the incinerator casing from rising 20*C above ambient temperature. - MARPOL VI/16.6.1 & MEPC 76(40)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2018
Resolved 19 July 2018
Resolution: Refractory to the incinerator door and furnance walls were renewed and found in good order.
Construction/Loadline › Structures › Superstructure
Issued 19 September 2016 Resolved
1230-RAILING CAT WALKS-A permanent gangway that is fitted with rail throughout its length and supported by stantions spaced not more than 1.5m apart. PSCO observed stanchion located near the top of the gangway disconnected from lower support causing an unsafe condition. ICLL 25-1/(2)(e)(vi) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2016
Resolved 19 September 2016
Resolution: PSCO observed ships crew satisfactorily effect repairs to stanchion that had rusted free of gangway. 10c

Ownership record