THE PELICAN

THE PELICAN is a 2002 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2018, most recently in June 2026, along with 28 deficiencies and 1 casualty investigation in 2006.

Records from 2006 to 2026. Most recent: inspection, 30 June 2026.

Built
2002
Last inspected
30 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 June 2026
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2018–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM8449
590312
Flag
UNITED STATES
Maury page id
psix-590312

Documentation record

Registered dimensions (L × B × D)60.0 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 42 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRI-KAT MARINE INC · GULFPORT, MS, UNITED STATES · built 2002
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portST PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Simplified, Gross Ton
33 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

30 June 2026 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8420178
10 November 2025 Examination of Repairs · Drydock Exam · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8123266
30 September 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8243886
2 October 2024 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7997025
5 June 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7906228
19 February 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7867217
12 January 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7848840
22 December 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7823819
25 September 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7797733
11 July 2023 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7690351
1 March 2022 Hull Examination · Deadweight Survey · Construction Oversight · Internal Structural Exam · Deficiency Check · Examination of Repairs · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7404405
23 August 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7296175
21 May 2018 Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6419560

Deficiency record · 28

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 October 2025 Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Waterlight was tied directly to the body of the life buoy. 46 CFR 180.70(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 October 2025
Resolution: Master installed a corrosion resistant clip.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 5 June 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of the individual who was directly involved in the SMI. MI observed alcohol testing swabs were not onboard. 46 CFR 4.06-15
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2024
Resolved 5 June 2024
Resolution: Test strips were purchased and placed onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 June 2024 Resolved
At each inspection the operator shall be prepared to conduct operational tests of all valves in the fuel system. MI observed a fuel supply valve, in the STBD engine fuel system, had a corroded valve handle that was no longer operational. Replace valve handle to the satisfaction of the Coast Guard. 46 CFR 176.804
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2024
Resolved 16 June 2024
Resolution: The valve was replaced, SAT.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 5 June 2024 Resolved
Vessels must comply with the applicable requirements for any radio installation as set forth in 47 CFR part 80 (FCC regulations). MI observed one VHF radio. For the vessel to operate past 20 miles offshore the vessel must also have a MF radio installation. Vessel is limited to operations within 20 miles of shore until an MF radio has been properly installed. 46 CFR 184.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2024
Resolved 22 August 2024
Resolution: Changed the vessels route from OCEANS to COASTWISE, MF no longer required.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2024 Resolved
46 CFR 180.202 (b) (1) Each vessel certificated to operate on an oceans route in warm water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board. Vessel reported that they lost a 30 person inflatable buoyant apparatus (IBA). Vessel still has one IBA of same capacity on board. CODE 705: Vessel can only carry a total of 44 persons until the life saving equipment COI requires is on board.
Action required: 705 - Other - as specified
Due 19 February 2024
Resolved 1 March 2024
Resolution: Vessel rented two 25 man life rafts to satisfy life saving requirements.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 September 2023 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel shall install system to the satisfaction of attending USCG Marine Inspector. 46 CFR 181.405(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2023
Resolved 22 December 2023
Resolution: Vessel installed system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 September 2023 Resolved
Flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. Vessel shall develop plan to the satisfaction of attending USCG Marine Inspector. 46 CFR 185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2023
Resolved 1 March 2024
Resolution: Charging station was designated.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2023 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. MI observed painter on both IBAs that was not attached to link. Vessel is restricted to stay within three nautical miles of shore until painter is properly secured to float-free link. 46 CFR 180.130(a)(1)
Action required: 705 - Other - as specified
Due 13 July 2023
Resolved 25 July 2023
Resolution: Vessel Capt. attached painters of both IBAs to float-free link per 3rd party servicing company. Vessel is no longer restricted to stay within three nautical miles of shore.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 July 2023 Resolved
By March 15 of the year following the collection of the data in paragraph (a) of this section, marine employers must submit the data on the form titled U.S Department of Transportation Drug and Alcohol Testing MIS Data Collection Form by mail to Commandant (CG-INV), or by internet. MI observed during DAPI audit, the vessel could not provide a copy of MIS report. 46 CFR 16.500(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 25 July 2023
Resolution: Vessel provided copy of latest MIS report for CY 22.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 July 2023 Resolved
Upon written request of an employer, Commandant (CG–INV) will review the employer's chemical testing program to determine compliance with the provisions of this part. MI observed during DAPI audit that vessel could not provide Letter of Regulatory Compliance for the Consortium. 46 CFR 16.205(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2023
Resolved 25 July 2023
Resolution: Vessel Capt. provided Inspector picture copy of Letter of Regulatory Compliance for the Consortium.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 11 July 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must: (3) Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. MI identified starboard/port engine room pre-engineered systems with expired dates on 3rd party servicing placards. Reviewed 3rd party fire servicing documentation from Jan. 2023 finding stbd system doesn't meet CG requirements requiring new parts. No other documentation stating new parts installed bringing system into regulatory compliance. 46 CFR 181.420(a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 12 July 2023
Resolution: Captain provided a 3rd Fire Servicing Cert. Conducted 12 Jul 2023 tested/inspected with no concerns - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2023 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. MI observed inoperable visual and audible alarms port and starboard high water bilge alarms for both engine rooms, and inoperable visual alarm starboard lazarette from the bridge. 46 CFR 182.530(a)(1)(2)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 13 July 2023
Resolution: Vessel Captain replaced port and starboard high water bilge audible and visual alarms, and starboard lazarette, all alarms annunciated on the bridge - all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 July 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of the individual who was directly involved in the SMI. MI observed alcohol testing swabs onboard were expired. 46 CFR 4.06-15(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 13 July 2023
Resolution: Vessel Captain provided four valid alcohol swabs - all sat.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 July 2023 Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, a serious marine incident, the marine employer shall take all practicable steps to have each individual engaged or employed onboard the vessel who is directly involved in the incident chemically tested for evidence of drug and alcohol use as required in this part. MI observed newly hired Captain was not aware of process(es) to be done following a serious marine incident as per the drug consortium requirements/regulations. 46 CFR 4.06-1(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 13 July 2023
Resolution: Vessel Captain discussed table top SMI with MI and was knowledgeable of process(es) and policies - all sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 July 2023 Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. MI was unable to open escape door from engine room by hand and there was no assist tools to open latching devices. 46 CFR 177.500(h)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 13 July 2023
Resolution: Reinspected escape door in engine room and MI was able to open door and was provided multiple assist tools to open latching devices - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 July 2023 Resolved
A hinged watertight bulkhead door must be fitted with a quick action closing device operable from both sides of the door. MI observed all vessel door were not watertight after vessel crew performed chalk test. 46 CFR 179.330(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 13 July 2023
Resolution: Reinspected all watertight doors on vessel after all gaskets were replaced - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 July 2023 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Flexible hose designed for use with hose clamps may be installed with two clamps, at both ends of the hose. MI observed both port/stbd main diesel engine strainers on the discharge side of strainer had non-metallic hoses that were severely dry-rotted. 46 CFR 182.720(e) & 46 CFR 182.720(e)(3)(v)(B)
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2023
Resolved 13 July 2023
Resolution: Discharge side of port and starboard main diesel engines had non-metallic hoses replaced - all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 July 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MI observed ball valve in stbd side hull in the steering compartment on bottom of the hull that had been used in previous equipment installation. Valve has opening that needs to be closed off completely. Captain discussed with MI and will be placing blind plug in valve. **705 C corrected within seven days.** 46 CFR 177.100
Action required: 705 - Other - as specified
Due 18 July 2023
Resolved 13 July 2023
Resolution: Ball valve in side hull of steering compartment was closed - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 11 July 2023 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. MI observed window located in main accommodation area port side all the way aft with multiple fractures from some previous type of impact. 46 CFR 177.1020
Action required: 705 - Other - as specified
Due 11 July 2023
Resolved 19 February 2024
Resolution: Window was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 July 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. MI observed emergency fuel shutoff valve for stbd side fuel tank in steering compartment did not close close completely. Crew adjusted valve handle and showed proper operation of valve closing completely. **Corrected on the spot.** 46 CFR 182.455(b)(4)
Action required: 10 - Deficiency Rectified
Due 11 July 2023
Resolved 11 July 2023
Resolution: Crew adjusted valve handle and showed proper operation of valve closing completely.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 July 2023 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers: (c) The name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radiobeacon (EPIRB). MI observed vessel's EPIRB did not have vessel's name labeled or printed on device. Crew labeled properly with vessels name. **Corrected on the spot.** 46 CFR 185.604(c)
Action required: 10 - Deficiency Rectified
Due 11 July 2023
Resolved 11 July 2023
Resolution: Crew labeled EPIRB properly with vessels name.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 27 June 2022 Resolved
Rail courses or the equivalent must be installed between a top rail required by paragraph (a) of this section, and the deck so that no open space exists that is more than 305 millimeters (12 inches) high except: On passenger decks of a ferry or of a vessel on an excursion trip the following must be installed: Bars, slats, rail courses, or an equivalent spaced at intervals of not more than 100 millimeters (4 inches). Rail courses found to be more than 4 inches on-board. 46 CFR 177.900 (g)
Action required: 705 - Other - as specified
Due 10 July 2022
Resolved 10 July 2022
Resolution: The operator installed high strength netting between rail courses to prevent passenger or crew falls overboard. The netting is rated to withstand more than 200 lbs of load.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 June 2022 Resolved
Each survival craft must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. The two IBA's attached to the top of the vessel do not have a float free device attached to them and will not deploy automatically if the vessel sinks. A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or other standard specified by the Commandant. 46 CFR 180.130
Action required: 17 - Rectify deficiencies prior to departure
Due 17 June 2022
Resolved 17 June 2022
Resolution: The owner placed an approved hydrostatic release unit on each IBA. The installation was reviewed by the MI using a photo of the installation.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2022 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. MI identified a fracture navigation light housing on the starboard running light and the mast light. The housing does not protect the navigation light to a weather tight integrity. 46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2022
Resolved 21 July 2022
Resolution: The operator installed new navigation light housing devices for the port and starboard running lights as well as the forward mast light.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2022 Resolved
Paragraphs (c) through (g) of 46 CFR 185.602 apply to each vessel that does not demonstrate compliance in accordance with § 178.310(c) of this chapter. Each vessel must have permanent draft marks at each end of the vessel; or have permanent loading marks placed on each side of the vessel forward and aft to indicate the maximum allowable trim and amidships to indicate the maximum allowable draft. The vessel is missing appropriate markings to indicate draft or loading marks. 46 CFR 185.602
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2022
Resolved 10 July 2022
Resolution: The operator measured the allowable trim per the approved stability letter and the hull is painted in a contrasting color to identify the maximum passenger loading mark.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 June 2022 Resolved
A vessel of not more than 19.8 meters (65 feet) in length is not required to carry a rescue boat unless: the vessel carries passengers on an open or partially enclosed deck and the cognizant OCMI determines that the vessel is designed, arranged, or involved in operations so that the vessel itself cannot serve as an adequate rescue craft. The rescue ladder does not conform to the OCMI specifications and does not meet the following: The platform landing shall be a minimum of 36 x 36 inches. The platform landing shall be constructed of expanded metal (mesh) to reduce the effect of wave action. The platform, when deployed, must be parallel to the water without breaking the surface. The platform must be of substantial construction and should be capable of supporting at least two persons (370 lbs) and must be able to withstand the effects of wave action. 46 CFR 180.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2022
Resolved 1 July 2022
Resolution: The operator installed a rescue platform at the stbd transom that complies with the Sector St. Petersburg MMS with the exception of it only being deployed from the one position on the port side.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2022 Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, at least two copies of the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI: Electrical installations and bilge piping systems. The owner made electrical modifications by adding an inverter on the bridge and made modifications to the bilge piping system. Submit amended plans to MSC for approval. 46 CFR 177.202
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2022
Resolved 19 February 2024
Resolution: Inverter was never wired in to ships electrical system and has been removed. Bilge system was approved by [name withheld] is in vessel documents.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 June 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Identified a fractured/holed weld at the inboard side of the starboard bow measuring less than 1 inch in length, located approximately 1 ft. aft of the bow (frame 0) on the main deck. Make satisfactory repairs to the fractured weld and contact a USCG MI for a re-inspection. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2022
Resolved 10 July 2022
Resolution: The operator cropped and welded the holed weld like and in kind to the existing weld construction.

Casualty record · 1

2 August 2006Routine · role: Involved in a Marine Casualty · activity 2733735
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

TRULA B (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.