Records from 2016 to 2026. Most recent: inspection, 16 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 12.8 ft × 7.9 ft
Registered tonnagegross 19 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRY B. NEVINS INC. · CITY ISLAND N Y, UNITED STATES · built 1934
Hull materialWood
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 23
16 March 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8327034
29 May 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8141914
18 March 2025
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8108416
18 July 2024
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7960559
6 December 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7838312
14 July 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7742438
12 May 2023
Drydock Extension · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7686956
14 July 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7506961
14 April 2022
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431480
23 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7318883
19 April 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7178961
22 February 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7153952
7 July 2020
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980363
6 April 2020
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6936147
11 December 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6872279
20 November 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6858059
7 October 2019
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6860711
8 July 2019
DAPI Audit · Annual Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6741756
19 July 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6482302
17 October 2017
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6291751
16 June 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6178134
14 November 2016
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6041880
14 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5907708
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2025
Resolved
FCC station license is expired. Renew station licenses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 14 July 2025
Resolution: Received proof license enroute via mail.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 29 May 2025
Resolved
DSC equipped VHF radio not provided with position data. Connect electronic position fixing device (GPS) to DSC equipped VHF radio to make the destress function operational. 47 CFR 80.1085(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 14 July 2025
Resolution: Position data now input into DSC enabled radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2024
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on
board the vessel... Alcohol testing strips onboard the vessel expired.
46CFR4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 31 July 2024
Resolution: Vessel purchased new test strips that expire in December of 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020
Resolved
Vessel must comply with the Federal Communications Commission as set forth in 47 CFR 80. The Safety Radiotelephony Certificate is expired. Required to replace prior to the carriage of passengers.
46 CFR 184.502
47 CFR 13
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2020
Resolved 22 February 2021
Resolution: Received valid certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 October 2019
Resolved
COI needs to be amended to reflect updates to the conditions to include maximum overnight passenger count and night watch requirements
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 7 February 2020
Resolution: COI amended with watch requirements.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 October 2019
Resolved
No smoke detector is currently installed in the forward accommodation space
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 10 March 2020
Resolution: Smoke detector installed in fwd accommodation space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2019
Resolved
Exit signs were not posted at all means of escape on the interior or exterior.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 7 July 2020
Resolution: All emergency exits were clearly marked. All sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2019
Resolved
The current arrangement for the main accommodation and forward accommodation emergency exits do not have a ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 10 March 2020
Resolution: Ladder rungs were installed to provide egress from accommodation space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2019
Resolved
Emergency escape securing devices are not operable from the exterior. Old-T/S regulations specify standards for hatches that provide access to accommodation spaces. 46 CFR (old) 177.13-1 sends you to 46 CFR (old) 171.124(c) for construction standards for hatches. It specifically states that hatches that provide access to accommodation spaces must be operable from both sides.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 10 March 2020
Resolution: The old emergency escape hatch has been redisignated as non emergency escape and the new emergency escape hatch is in the fwd accomm space, which is operable from both sides.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 July 2019
Resolved
VESSEL DID NOT HAVE A CURRENT/VALID COD ONBOARD.
Updated 7/18/19: Changing from code 17C to 50C, IAW MSIB 03-19
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2019
Resolved 24 September 2019
Resolution: Owner rcvd new COD and provided copy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2019
Resolved
TWO LIFE JACKETS WERE NOT MARKED WITH THE VESSEL NAME
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 10 July 2019
Resolution: LIFE JACKETS WERE MARKED AS REQUIRED. MASTER SENT PHOTO AS PROOF.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2019
Resolved
VESSEL DID NOT HAVE AN UP TO DATE COAST GUARD LIGHT LIST ONBOARD. THE LIGHT LIST ON BOARD IS SEVERAL YEARS OLD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 10 July 2019
Resolution: Master provided proof of up to date Light List.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 July 2019
Resolved
THE VESSEL DOES NOT HAVE THE ABILITY TO REMOTELY SECURE THE FUEL SUPPLY VALVES AT THE FUEL TANK FROM OUTSIDE OF THE ENGINE SPACE. THE ONLY REMOTE VALVE IS AT THE ENGINE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Remote fuel stop cables have been installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 July 2019
Resolved
THE DIESEL FUEL TANK VENT PIPES ARE SMALLER THAN THE REQUIRED SIZE OF .0625" FOR FILL PIPES THAT TERMINATE AT THE TOP OF THE TANK.
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Proper size vents were installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 July 2019
Resolved
THE EXISTING FUEL TANK VENTS DO NOT HAVE FLAME SCREENS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2020
Resolution: Flame screens were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2019
Resolved
REMOTE FUEL SHUTOFF STATIONS MUST BE CLEARLY MARKED.
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Remote fuel valves have been installed and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2018
Resolved
11117 46CFR180.70(d) 16C: A vessel must carry one floating waterlight, unless it is limited to daytime operation. Vessel's waterlight is functioning with battery past service life. Replace battery with appropriate rated battery and provide documentation as proof.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2018
Resolved 19 July 2018
Resolution: Vessel representative provided photograph proof of newly installed battery of the proper type.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 16 June 2017
Resolved
Drug and alcohol program Employee Assistance Program (EAP) not in effect. Conduct required training. 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 16 August 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 June 2016
Resolved
Replace expired alcohol testing strips. 46 CFR 16.240, 46 CFR 4.06
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Vessel replaced expired alcohol testing strips.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 June 2016
Resolved
Replace condemned life jackets with appropriate number to comply with 28 pax indicated on COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Vessel replaced condemned lifejackets with 02 new ones.