MAURY USCG vessel records Sign in
← All vessels

ORION

ORION is a 1934 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1987, most recently in March 2026, along with 61 deficiencies.

Records from 1987 to 2026. Most recent: inspection, 16 March 2026.

Built
1934
Last inspected
16 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBE6225
Flag
UNITED STATES
338356000
Maury page id
psix-59072

Inspections, by type

…with no type recorded8
Years with a record 35 calendar years (1987–2026)
The 77 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 12.8 ft × 7.9 ft
Registered tonnagegross 19 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRY B. NEVINS INC. · CITY ISLAND N Y, UNITED STATES · built 1934
Hull materialWood
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 17 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ4366MMSI 338356000 · active · compulsorily equipped · granted 18 June 2025, expires 18 June 2035
WDH6361MMSI 338356000 · expired · compulsorily equipped · granted 20 August 2014, cancelled 23 November 2024
WBE6225MMSI 367165180 · expired · voluntarily equipped · granted 7 February 2007, cancelled 15 April 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 77

16 March 2026 Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8327034
29 May 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8141914
18 March 2025 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8108416
18 July 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7960559
6 December 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7838312
14 July 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7742438
12 May 2023 Drydock Extension · Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7686956
14 July 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7506961
14 April 2022 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431480
23 June 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7318883
19 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7178961
22 February 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7153952
7 July 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6980363
6 April 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6936147
11 December 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6872279
20 November 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6858059
7 October 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6860711
8 July 2019 DAPI Audit · Annual Inspection · In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6741756
19 July 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6482302
17 October 2017 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6291751
16 June 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6178134
14 November 2016 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6041880
14 June 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5907708
5 November 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5760642
12 June 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4884105
20 June 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4344996
28 May 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4326016
30 October 2008 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3350661
3 October 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3316174
29 September 2006 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2775787
11 July 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2705051
16 May 2005 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2349251
27 September 2004 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2204029
2 April 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2036248
19 May 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1796804
1 October 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1679418
16 April 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1606473
12 March 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379332
15 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1426657
7 February 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 17357
28 September 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471029
16 March 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1365640
31 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 783611
25 February 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1440115
15 January 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 811487
28 September 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1408180
3 May 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1123904
10 April 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1388508
20 March 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396686
29 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 212155
27 September 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1357747
3 June 1996 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1084249
29 February 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1359097
3 May 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1456272
14 February 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409237
9 January 1995 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1454143
24 March 1994 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394084
19 November 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 73823
19 November 1993 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 221317
23 July 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1138479
8 March 1993 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 838059
4 March 1993 COI Inspection · Drydock Extension
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 835584
18 March 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 960334
26 July 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 998724
8 March 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 911924
8 June 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 904144
26 March 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 908059
8 March 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1214712
9 January 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 929753
6 April 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1034171
27 March 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1037354
28 October 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 889558
7 July 1988 Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1207588
21 September 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1007914
3 August 1987 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1334935
1 July 1987 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1010280
30 March 1987 Plan Review "T" Boat · Initial Certification · Hull Examination · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1326049

Deficiency record · 61

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 May 2025 Resolved
FCC station license is expired. Renew station licenses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 14 July 2025
Resolution: Received proof license enroute via mail.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 29 May 2025 Resolved
DSC equipped VHF radio not provided with position data. Connect electronic position fixing device (GPS) to DSC equipped VHF radio to make the destress function operational. 47 CFR 80.1085(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2025
Resolved 14 July 2025
Resolution: Position data now input into DSC enabled radio.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2024 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel... Alcohol testing strips onboard the vessel expired. 46CFR4.06-15(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2024
Resolved 31 July 2024
Resolution: Vessel purchased new test strips that expire in December of 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020 Resolved
Vessel must comply with the Federal Communications Commission as set forth in 47 CFR 80. The Safety Radiotelephony Certificate is expired. Required to replace prior to the carriage of passengers. 46 CFR 184.502 47 CFR 13
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2020
Resolved 22 February 2021
Resolution: Received valid certificate.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 October 2019 Resolved
COI needs to be amended to reflect updates to the conditions to include maximum overnight passenger count and night watch requirements
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 7 February 2020
Resolution: COI amended with watch requirements.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 October 2019 Resolved
No smoke detector is currently installed in the forward accommodation space
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 10 March 2020
Resolution: Smoke detector installed in fwd accommodation space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2019 Resolved
Exit signs were not posted at all means of escape on the interior or exterior.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 7 July 2020
Resolution: All emergency exits were clearly marked. All sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2019 Resolved
The current arrangement for the main accommodation and forward accommodation emergency exits do not have a ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 10 March 2020
Resolution: Ladder rungs were installed to provide egress from accommodation space.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2019 Resolved
Emergency escape securing devices are not operable from the exterior. Old-T/S regulations specify standards for hatches that provide access to accommodation spaces. 46 CFR (old) 177.13-1 sends you to 46 CFR (old) 171.124(c) for construction standards for hatches. It specifically states that hatches that provide access to accommodation spaces must be operable from both sides.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2019
Resolved 10 March 2020
Resolution: The old emergency escape hatch has been redisignated as non emergency escape and the new emergency escape hatch is in the fwd accomm space, which is operable from both sides.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 July 2019 Resolved
VESSEL DID NOT HAVE A CURRENT/VALID COD ONBOARD. Updated 7/18/19: Changing from code 17C to 50C, IAW MSIB 03-19
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2019
Resolved 24 September 2019
Resolution: Owner rcvd new COD and provided copy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2019 Resolved
TWO LIFE JACKETS WERE NOT MARKED WITH THE VESSEL NAME
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 10 July 2019
Resolution: LIFE JACKETS WERE MARKED AS REQUIRED. MASTER SENT PHOTO AS PROOF.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 July 2019 Resolved
VESSEL DID NOT HAVE AN UP TO DATE COAST GUARD LIGHT LIST ONBOARD. THE LIGHT LIST ON BOARD IS SEVERAL YEARS OLD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2019
Resolved 10 July 2019
Resolution: Master provided proof of up to date Light List.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 July 2019 Resolved
THE VESSEL DOES NOT HAVE THE ABILITY TO REMOTELY SECURE THE FUEL SUPPLY VALVES AT THE FUEL TANK FROM OUTSIDE OF THE ENGINE SPACE. THE ONLY REMOTE VALVE IS AT THE ENGINE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Remote fuel stop cables have been installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 July 2019 Resolved
THE DIESEL FUEL TANK VENT PIPES ARE SMALLER THAN THE REQUIRED SIZE OF .0625" FOR FILL PIPES THAT TERMINATE AT THE TOP OF THE TANK.
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Proper size vents were installed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 July 2019 Resolved
THE EXISTING FUEL TANK VENTS DO NOT HAVE FLAME SCREENS.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2020
Resolution: Flame screens were installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 July 2019 Resolved
REMOTE FUEL SHUTOFF STATIONS MUST BE CLEARLY MARKED.
Action required: 705 - Other - as specified
Resolved 10 March 2020
Resolution: Remote fuel valves have been installed and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 July 2018 Resolved
11117 46CFR180.70(d) 16C: A vessel must carry one floating waterlight, unless it is limited to daytime operation. Vessel's waterlight is functioning with battery past service life. Replace battery with appropriate rated battery and provide documentation as proof.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2018
Resolved 19 July 2018
Resolution: Vessel representative provided photograph proof of newly installed battery of the proper type.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 16 June 2017 Resolved
Drug and alcohol program Employee Assistance Program (EAP) not in effect. Conduct required training. 46 CFR 16.401
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2017
Resolved 16 August 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 June 2016 Resolved
Replace expired alcohol testing strips. 46 CFR 16.240, 46 CFR 4.06
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Vessel replaced expired alcohol testing strips.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 June 2016 Resolved
Replace condemned life jackets with appropriate number to comply with 28 pax indicated on COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2016
Resolution: Vessel replaced condemned lifejackets with 02 new ones.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 June 2014 Resolved
Vessel shall have an FCC Inspector conduct safety check of radio. Send copy of FCC Safety Certificate to Marine Inspector. 47 CFR 80 27JUN14.
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 26 August 2014
Resolution: Vessel received new FCC communications act sadety radiotelephony certificate.
Lifesaving › Hand Flares › Quantity
Issued 12 June 2014 Resolved
Vessel shall have required amount and type of distress signals to the satisfaction of the attending Marine Inspector. 46 CFR 180.68(a)(1) and (2) 27JUN14
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 24 June 2014
Resolution: Received receipt of appropriate number and type of flares (4 pack of red flares and 3 pack of orange smoke) from vessel owner.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 12 June 2014 Resolved
Vessel shall have up-to-date and valid mag compass deviation table upon completion of compass swing to the satisfaction of the attending Marine Inspector. 46 CFR 180.20-1 27JUN14
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 26 June 2014
Resolution: Vessel sent copy of updated deviation table card.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 June 2014 Resolved
Vessel is restricted to carry 23 passengers maximum due to 2 condemed lifejackets. 2 approved lifejackets required to meet full passenger count to the satisfaction of the attending Marine Inspector. 46 CFR 180.71(a) and (b) 27JUN14
Action required: 705 - Other - as specified
Due 27 June 2014
Resolved 24 June 2014
Resolution: Received receipt from vessel owner of 2 adult Type I PFD.
Documentation › Logs/Records › Drug Test Records
Issued 30 October 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 25 November 2008
Communications › Radio Communications › EPIRB
Issued 30 October 2008 Resolved
Provide current EPIRB NOAA registration, vessel restricted to 3NM from shore until provided.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 25 November 2008
Lifesaving › Buoyant Smoke Signals › General
Issued 30 October 2008 Resolved
Provide an additional (3) orange smoke signals.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 25 November 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 October 2008 Resolved
Replace expired aspirin in first aid kit.
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 25 November 2008
Navigation › Piloting/Steering › Marine Charts
Issued 30 October 2008 Resolved
Provide currently corrected chart of SD Bay (18773).
Action required: 705 - Other - as specified
Due 14 November 2008
Resolved 25 November 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 11 July 2006 Resolved
Replace 4 adult and 3 children lifejackets.
Action required: 705 - Other - as specified
Resolved 24 July 2006
Resolution: Lifejackets are replaced.
Fire Fighting › Fire Bucket › Stenciling
Issued 11 July 2006 Resolved
Stencil 3 fire buckets.
Due 17 August 2006
Resolved 24 July 2006
Resolution: Buckets are stenciled.
Lifesaving › Hand Flares › Quantity
Issued 16 May 2005 Resolved
Found vessel lacking 3 required orange distress signals for limited coastwise route. Restricted vessel to LBS route until adequate flares provided IAW 46CFR180.68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 20 May 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 May 2005 Resolved
Found stern light cover missing. Repair IAW 46CFR183.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 14 July 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 May 2005 Resolved
Portable emergency lights (flashlights) did not work. Prove proper operation IAW 46CFR183.430.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 20 May 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 May 2005 Resolved
Found outdated CG Light List on-board. Provide updated version, or excerpts of same for routes transited IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 20 May 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 May 2005 Resolved
Found outdated US Coast Pilot on-board. Provide updated version, or excerpts of same for routes transited IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 20 May 2005
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 May 2005 Resolved
Found outdated Tide Tables on-board. Provide updated version, or excerpts of same for routes transited IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 20 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 May 2005 Resolved
Found outdated items (asprin & eyewash) in first aid kit. Renew items IAW 46CFR184.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 20 May 2005
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 16 May 2005 Resolved
Prove establishment of on-shore crew & passenger count reporting system IAW 46CFR185.504.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2005
Resolved 20 May 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 April 2004 Resolved
Renew sternlight lens.
Due 15 May 2004
Resolved 28 July 2004
Resolution: Issue was resolved in April but never cleared from MISLE.
Electrical › Electrical Distribution System (service)
Issued 19 May 2003 Resolved
Install metallic clamps every 24 inches in engineroom for overhead wiring IAW 46 CFR 183.340(b)(4). LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 27 April 2004
Lifesaving › Hand Flares
Issued 19 May 2003 Resolved
Provide (6) hand red flares and (6) hand orange smoke distress signals IAW 46 CFR 180.68(a). LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 27 April 2004
Electrical › Lighting (service)
Issued 18 April 2002 Resolved
Provide cover for bare bulb in radio space LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 16 May 2002
Resolved 29 April 2002
Electrical › Lighting (service)
Issued 18 April 2002 Resolved
Rewire fixture above PFDs into JCT box. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 16 May 2002
Resolved 29 April 2002
Documentation › Certificates/Documents
Issued 18 April 2002 Resolved
Provide FCC safety certificate. LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Due 16 May 2002
Resolved 29 April 2002
Documentation › Certificates/Documents
Issued 18 April 2002 Resolved
Provide FCC Operators license LEGACY COMPONENT DESC: FCC SSL
Condition: Unknown
Due 16 May 2002
Resolved 29 April 2002
Electrical
Issued 28 September 1998 Resolved
PROPERLY WIRE CABLING IN VICINITY OF REEFER STBD SIDE.
Condition: Unknown
Due 12 October 1998
Resolved 1 October 1998
Engineering
Issued 28 September 1998 Resolved
PROVIDE FLAME IMPINGEMENT BOWL FOR FUEL FILTER.
Condition: Unknown
Due 12 October 1998
Resolved 1 October 1998
Engineering
Issued 28 September 1998 Resolved
REPLACE STERN STRUT BEARING.
Condition: Unknown
Due 12 October 1998
Resolved 1 October 1998
Lifesaving
Issued 10 April 1998 Resolved
PROVIDE RETRO-REFLECTIVE TAPE ON LIFE RING BUOY.
Condition: Unknown
Due 24 April 1998
Resolved 3 May 1998
Lifesaving
Issued 10 April 1998 Resolved
PROVIDE THREE ADDITIONAL ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 24 April 1998
Resolved 3 May 1998
Electrical
Issued 10 April 1998 Resolved
INSTALL COVER PLATE OVER OPEN HOLE IN BREAKER PANEL.
Condition: Unknown
Due 24 April 1998
Resolved 3 May 1998
Documentation
Issued 29 February 1996 Resolved
Provide compliance with DOT random drug testing program.
Condition: Unknown
Due 29 March 1996
Resolved 30 April 1996
Navigation
Issued 8 March 1990 Resolved
PROVIDE TWO(2) RED LIGHTS FOR NAVIGATION GROUNDING SIGNALS AT NIGHT.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Navigation
Issued 8 March 1990 Resolved
PROVIDE ONE ADDITIONAL BLACK BALL DAY SHAPES.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Engineering
Issued 8 March 1990 Resolved
REPAIR TACHOMETER FOR THE AUXILIARY DIESEL PROPULSION.
Condition: Unknown
Due 8 March 1990
Resolved 8 March 1990
Unknown
Issued 27 March 1989 Resolved
INSTALL A COAST GUARD APPROVED MARINE SANITATION DEVICE HOLDING TANK.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Lifesaving
Issued 27 March 1989 Resolved
PROVIDE A COAST GUARD APPROVED WATER LIGHT FOR EACH OF THE TWO(2) BUOYANT APPARATUS.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Lifesaving
Issued 7 July 1988 Resolved
PROVIDE NEW HAND HELD FLARES.
Condition: Unknown
Due 7 July 1988
Resolved 7 July 1988
Fire Fighting
Issued 7 July 1988 Resolved
SERVICE PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 7 July 1988
Resolved 7 July 1988
Construction/Loadline
Issued 30 March 1987 Resolved
PROPERLY SEAL OR INSTALL VALVES ON SCUPPER PIPING WHERE THEY PENETRATE THE HULL BELOW THE WATERLINE.
Condition: Unknown
Due 30 March 1987
Resolved 30 March 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.