MAURY USCG vessel records Sign in
← All vessels

GOLD DUST

GOLD DUST is a 1934 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 1992, most recently in October 2006, along with 52 deficiencies.

Records from 1992 to 2006. Most recent: inspection, 6 October 2006.

Built
1934
Last inspected
6 October 2006
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCD 6364
Flag
UNITED STATES
—
Maury page id
psix-59119

Inspections, by type

…with no type recorded2
Years with a record 13 calendar years (1992–2006)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.6 ft × 18.0 ft × 4.1 ft
Registered tonnagegross 41 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEVINGSTON SHIPBUILDING C · ORANGE TX, UNITED STATES · built 1934
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONROE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCD6364MMSI not assigned · expired · compulsorily equipped · granted 15 December 1998, cancelled 14 March 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 22

6 October 2006 Deficiency Check
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2797182
21 September 2006 COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 2783585
27 January 2005 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2305990
26 August 2004 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2177768
20 August 2003 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1883903
16 July 2002 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1652673
24 May 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1366373
25 October 2000 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1055233
25 September 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382050
25 July 2000 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 665899
28 June 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1369770
10 September 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1119171
16 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 883973
11 May 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411877
13 August 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 796234
8 July 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1416728
29 April 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394728
11 July 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1090127
15 May 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411291
10 January 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 883926
31 May 1995 Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435652
17 November 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 689813

Deficiency record · 52

Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 September 2006 Resolved
Replace Port & STBD Nav. lights with proper type meeting Inland Navigation Rules COMDINST M16672.2. Restricted to daylight operations until replaced.
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 21 September 2006
Resolution: Research showed that the INLAND RULES Part E - EXEMPTIONS clearly permanently exempts this 1934 vessel from the intensity & color specifications.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 September 2006 Resolved
Remove & replace improper outside light. Use proper marine grade UL light fixtures.
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 6 October 2006
Resolution: Exterior lights purchased.
Communications › Audible Communications › SPD (Other)
Issued 21 September 2006 Resolved
Prove proper operation or Public Address system.
Action required: 705 - Other - as specified
Due 21 October 2006
Resolved 6 October 2006
Resolution: PA system works off the VHF radio , owner found a loose wire. All sat.
Construction/Loadline › Structures › Superstructure
Issued 26 August 2004 Resolved
Screening on the outside of the upper part of pilot house needs to be replaced. Will complete at next dry dock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 September 2006
Resolution: sat
Construction/Loadline › Structures › Machinery Space Opening
Issued 26 August 2004 Resolved
Access doors to the engine room need to be replaced. Will complete at next dry dock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 September 2006
Resolution: sat
Construction/Loadline › Structures › Deck Plating
Issued 26 August 2004 Resolved
Replace weakened areas on the top deck. Will complete at next dry dock.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 21 September 2006
Resolution: sat
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 August 2004 Resolved
Provide a storage place for children's lifejackets.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 September 2004
Resolved 1 September 2004
Resolution: Child life jackets (6) stored separately in containers marked with type and quantity.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 26 August 2004 Resolved
Stencil life jacket containers indicating type and quantity. Will complete at next dry dock.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 September 2004
Resolved 1 November 2004
Resolution: Life jacket containers properly stenciled.
Construction/Loadline › Structures › Superstructure
Issued 26 August 2004 Resolved
Replace broken aft stbd side window.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 September 2004
Resolved 20 September 2004
Resolution: Window replaced on aft stbd side.
Lifesaving › Lifebuoys
Issued 20 August 2003 Resolved
Label vessel's name on life ring. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 20 September 2003
Resolved 30 September 2003
Engineering › Diesel Engine (auxiliary)
Issued 20 August 2003 Resolved
Replace belt guard on Genset.
Due 20 September 2003
Resolved 30 September 2003
Electrical › Electric Supply System (service)
Issued 20 August 2003 Resolved
If battery charger is desired, remove spring clips and permanently attach cable leads. LEGACY COMPONENT DESC: Battery Charger
Due 20 September 2003
Resolved 30 September 2003
Fire Fighting › Structural Fire Protection - General
Issued 20 August 2003 Resolved
Reattach fire protection in overhead of engineroom.
Due 20 September 2003
Resolved 30 September 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 20 August 2003 Resolved
Move both BII fire extinguishers outside of the machinery space. LEGACY COMPONENT DESC: Location
Due 20 September 2003
Resolved 30 September 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 August 2003 Resolved
Repair exhaust leaks on Main Engine and Genset. LEGACY COMPONENT DESC: Piping (exhaust)
Due 20 September 2003
Resolved 30 September 2003
Engineering › Bilge Water Management System › Pump
Issued 16 July 2002 Resolved
Permanently mount bilge pump and prove proper operation.
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 July 2002 Resolved
Prove proper operation and properly secure bilge high level alarm float switch.
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Engineering › Bilge Water Management System › Hose
Issued 16 July 2002 Resolved
Provide adequate length of discharge hose for portable bilge pump. Hose needs to reach overboard.
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 July 2002 Resolved
Replace line on life ring and float light assembly.
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 16 July 2002 Resolved
Provide a minimum of (3) orange smoke distress signals.
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Communications › Audible Communications
Issued 16 July 2002 Resolved
Prove proper operation of the PA system and VHF radio. 12 volt system is OOC at present time. LEGACY COMPONENT DESC: PA System and VHF Radio
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 July 2002 Resolved
Replace expired items in First Aid kit. LEGACY COMPONENT DESC: Kit
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 July 2002 Resolved
Replace life jacket donning instruction placard at port side pilot house life jacket locker.
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 16 July 2002 Resolved
Provide (3) additional adult life jackets. Vessel can carry no more than 46 adult passengers until this requirement can be met.
Due 16 August 2002
Resolved 15 August 2002
Resolution: Corrected.
Accommodation/Occupational Safety
Issued 24 May 2001 Resolved
Repair/ replace loudspeaker in salon room.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Lifesaving
Issued 24 May 2001 Resolved
Remove flammables from galley.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Navigation
Issued 24 May 2001 Resolved
Provide an emergency tiller that can be installed rapidly.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Construction/Loadline
Issued 25 September 2000 Resolved
Renew wasted area of the fwd bulkhead in the engine room on the port side._x001C_
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Construction/Loadline
Issued 25 September 2000 Resolved
Renew gaskets on both hatch covers._x001C_
Condition: Unknown
Due 25 September 2000
Resolved 25 September 2000
Documentation
Issued 28 June 2000 Resolved
Present vessel for drydock inspection.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Lifesaving
Issued 28 June 2000 Resolved
Perform drug testing of 50% of crew.
Condition: Unknown
Due 28 June 2000
Resolved 28 June 2000
Lifesaving
Issued 16 June 1999 Resolved
Provide documetation on drug testing program for your vessel crew.
Condition: Unknown
Due 16 June 1999
Resolved 16 June 1999
Electrical
Issued 11 May 1999 Resolved
Prior to carrying passengers, replace Acc. belt on gen-set.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 11 May 1999 Resolved
Provide training records for emergency drills carried out.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 11 May 1999 Resolved
Provide marine grade flexible electrical cable, instead of household wiring, in engine room.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 11 May 1999 Resolved
Provide one or more child life-jackets.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 11 May 1999 Resolved
Prior to carrying passengers, provide approved first aid kit.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 11 May 1999 Resolved
Provide records for drills conducted.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 11 May 1999 Resolved
Label current breakers in C.B. boxes.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 11 May 1999 Resolved
Prior to carrying passengers, provide new life ring.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Lifesaving
Issued 11 May 1999 Resolved
Provide plcards on how to don life-jackets.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 11 May 1999 Resolved
Provide frequency meter on gen-set.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Engineering
Issued 11 May 1999 Resolved
Provide metal flash bowl on Racor fuel filter and metal plug.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Electrical
Issued 11 May 1999 Resolved
Provide proper electrical wire splices at main engine.
Condition: Unknown
Due 11 May 1999
Resolved 11 May 1999
Navigation
Issued 8 July 1998 Resolved
Relocate mast head light above existing search light.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 8 July 1998 Resolved
Remove inoperative compressor and associated air receiver from engine room.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 8 July 1998 Resolved
Provide Coast Guard approved water light and attach with 3 foot lanyard with clip to life ring.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 8 July 1998 Resolved
Install hand guards over main engine and generator pulleys.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Documentation
Issued 8 July 1998 Resolved
Provide proof of renewal of Certificate of Documentation.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 15 May 1996 Resolved
COMPLETE CHEMICAL TESTING PROGRAM AUDIT FORM (B) AND ENSURE COMPLIANCE WITH46 CFR PART 16.
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996
Documentation
Issued 31 May 1995 Resolved
PROVIDE ON BOARD VESSEL A SMALL PASSENGER VESSEL SIMPLIFIED STABILITY TEST LETTER.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Documentation
Issued 31 May 1995 Resolved
PROVIDE PROOF THAT USER FEES FOR INSPECTIONS HAVE BEEN PAID.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.