Professional
The full record for this vessel
Behind this panel: 10 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 10
3 June 2021
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7213864
3 December 2020
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7103237
28 December 2019
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6880147
1 December 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6862599
22 October 2019
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6839261
3 June 2019
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6698848
3 May 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6670768
30 October 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6294627
29 November 2016
Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6048965
30 October 2016
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6026873
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 December 2019
Resolved
Means shall be provided to prevent overpressure in any part of compressed air systems that is subjected to dangerous overpressure due to leakage into them from air pressure parts, suitable pressure relief arrangements shall be provided.
Found emergency generator fuel shutoff valve air pressure relief discharge capped, preventing relief valve from relieving as designed.
SOLAS(04) II-1/34.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 December 2019
Resolved 28 December 2019
Resolution: SAFETY VALVE WAS REPLACED. CLASS CLEARED
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 December 2019
Resolved
The arrangements shall ensure that the tightness can be maintained in any sea conditions.
Cargo hold upper deck and starboard bunker station weathertight doors were unable to be closed and secured.
ICLL ANNEX I, REG 16.4
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 December 2019
Resolution: WATER TIGHT DOOR HAS BEEN REPAIRED. CLASS CLEARED
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 1 December 2019
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural requirements of a classification society.
Top left corner of the bulkhead going into paint locker has a 25cm crack.
SOLAS(04) II-1/3-1
Action required: 10 - Deficiency Rectified
Resolved 28 December 2019
Resolution: AFT WALL WAS REPAIRED. CLASS CLEARED
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 1 December 2019
Resolved
Condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or the persons on board.
Engine room control center engine order telegraph mismatch bell not functioning as designed.
SOLAS(04) I/11(a)
Action required: 10 - Deficiency Rectified
Resolved 28 December 2019
Resolution: ECR ENGINE TELEGRAPH BELL WAS REPAIRED. CLASS CLEARED
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 December 2019
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner.
Found SCBA compressor and laundry washing machines with unnaproved electrical installations.
SOLAS(04) II-1/45.1.3
Action required: 10 - Deficiency Rectified
Resolved 28 December 2019
Resolution: ELECTRICAL INSTALLATIONS HAVE BEEN APPROVED. CLASS CLEARED
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 3 June 2019
Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the United States must remove fouling organisms from the vessel's hull on a regular basis and dispose of any removed substances in accordance with local, state and Federal regulations. Vessl's hull has organic grouwth below the waterline from bow to amidships. 33CFR151.2050(f) 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2019
Resolved 21 October 2019
Resolution: master provided dry dock report detailing new bottom paint application.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 3 May 2019
Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS ASSOCIATED PIPING SYSTEM AND FITTINGS SHALL BE SE INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM AN DANGER TO PERSONS ON BOARD DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. LOW PRESSURE CO2 REFRIGERATION PUMPS FOUND WITH UNPROTECTED MOVING PARTS.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 June 2019
Resolution: Guards were installed around the exposed moving parts
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2019
Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. VESSEL ACCOMODATION HOT WATER, MACHINERY, AND PIPING ARE NONOPERATIONAL.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 June 2019
Resolution: Working hot water was observed in galley and separate wash basins
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 May 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 June 2019
Resolution: Fouling Maintenance Procedures manual observed on board
Documentation › Certificates/Documents › IOPP Certificate
Issued 30 October 2016
Resolved
In every case the administration shall guarantee the completeness and efficiency of the survey and shall undertake to ensure the necessary arrangements to satisfy this obligation. The IOPP Supplement indicates the OWS equipment in engine room is MEPC 60 standard; equipment in engine room is MEPC 107, contrary to IOPP documentation. MARPOL (2011 ED.) Annex 1 Reg. 6.3.4
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 29 November 2016
Resolution: Vessel provided an updated IOPP Certificate.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 October 2016
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. Spliced cables and unapproved lighting equipment were found routed throughout the ship's main machinery space of category A, over piping, against bulkheads and also includes the relocation of electrical outlets to accomodate such lighting installations. SOLAS 74(2004) II-1/40.1.3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 29 November 2016
Resolution: Vessel provided classification correspondence that attests to the removal of the electrical installations.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 30 October 2016
Resolved
The condition of the ship and its equipment shall be maintained to conform with present regulataions to ensure that the ship is fit to proceed to sea without danger to ship or crew. Flammable liquids and HAZMAT containers were found throughout machinery spaces, greatly increasing flammability ignition in those spaces, and not stored adequately in designated space. See attached Form B.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 29 November 2016
Resolution: Vessel provided classification society correspondence attesting to the removal and relocation of HAZMAT to the proper location.