MAURY USCG vessel records Sign in
← All vessels

GLADES

GLADES is a 2002 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2002, most recently in April 2025, along with 34 deficiencies and 1 casualty investigation in 2005.

Records from 2002 to 2025. Most recent: inspection, 29 April 2025.

Built
2002
Last inspected
29 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK3229
591640
Flag
UNITED STATES
368043160
Maury page id
psix-591640

Inspections, by type

…with no type recorded1
Years with a record 14 calendar years (2002–2025)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 11.3 ft × 3.2 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCANAL BOATS INC · FORT LAUDERDALE, FL, UNITED STATES · built 2002
Hull materialFRP (Fiberglass)
PropulsionElectric Motor
Hull shapeBox
Hull configurationMonohull
Hailing portFORT LAUDERDALE, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK3229MMSI 368043160 · active · compulsorily equipped · granted 6 June 2018, expires 6 June 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 23

29 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8123900
23 April 2025 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8117830
19 September 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8005679
11 July 2023 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7742368
14 June 2023 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7714769
1 June 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7473765
27 April 2022 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7439335
26 August 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7295433
20 November 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7100341
5 August 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7025139
26 November 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6863278
23 August 2018 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6487870
27 June 2018 Simplified Stability Test
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6477865
15 August 2017 Initial Certification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6241153
23 October 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2808324
13 April 2006 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2624106
11 December 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2563243
17 November 2005 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2534845
23 November 2004 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2246562
12 October 2004 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2214965
4 August 2004 In-Service Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2155733
24 September 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1911642
18 September 2002 Plan Review "T" Boat · Hull Examination · Simplified Stability Test · COI Inspection · Construction Oversight
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1686199

Deficiency record · 34

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 April 2025 Resolved
46 CFR 182.455(b)(6) A suitable metal marine type strainer shall be fitted in the fuel supply line in the engine compartment... A drip pan fitted with flame screen shall be installed under the strainer. Flame screen was missing from the bottom of the fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2025
Resolved 22 May 2025
Resolution: Recieved photo evidence from vessel owner of flame bowl installed under the fuel filter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2025 Resolved
46 CFR 160.050(c) The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. The grab line of the life ring buoy was deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2025
Resolved 16 May 2025
Resolution: Received picture evidence of grab line replacement for the life ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 April 2025 Resolved
46 CFR 185.604(h) Each life jacket must be marked with Type I retroreflective material. Five life jackets were missing Type I reflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 April 2025
Resolved 23 April 2025
Resolution: Vessel rep immediately added retroreflective tape to the five lifejackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2024 Resolved
46 CFR 183.200 (b): Provide services necessary for safety under normal and emergency conditions. Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Minimize accidental personnel contact with energized parts; and Prevent electrical ignition of flammable vapors. Battery space has loose connections, repair/replace to satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 19 December 2024
Resolution: Loose connections secured, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 September 2024 Resolved
47 CFR 80.903: Inspection of Radiotelephone instillation every 5 years. Radiotelephone certificate has expired, replace to the satisfaction on CG Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2024
Resolved 19 December 2024
Resolution: cert replaced, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 September 2024 Resolved
46 CFR 181.420: A pre-engineered fixed gas fire extinguishing system...installed IAW manufacturers instructions. Replace the rusted corroded bracket holding the gas bottle in engine room to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2024
Resolved 19 December 2024
Resolution: Bracket replaced, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 20 November 2020 Resolved
Observed longitudinal stringer in starboard side of engine room with a crack running approximately 8 inches running the length of the stringer. Make proper repairs to crack in longitudinal stringer.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Observed repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2020 Resolved
Observed inadequate support brackets for fuel line in Void #2. Install proper support brackets for fuel line.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Observed newly installed support brackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 November 2020 Resolved
Observed daylight shining through around the perimeter of the hatch located on the forward watertight bulkhead of the E/R. Make proper repairs to hatch to ensure water tight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Filled through hull penetrations in bulkhead.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 20 November 2020 Resolved
Observed excessive oily bilge water in the E/R and Void #2 bilges. Clean up bilges.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Operator cleaned up bilge. No oily bilge water observed after clean up.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 November 2020 Resolved
Observed failed water tight integrity of inspection port for foreward peak tank. Make proper repairs to inspection port to ensure water tight integrity.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Made repairs to inspection port to ensure watertight integrity.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2020 Resolved
The audible alarm for the high water level indicator for Void #1 is not working. Make proper repairs to audible alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Successfully tested high water bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2020 Resolved
Vessel missing life jacket donning instructions. Properly display life jacket donning instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Operator installed life jacket donning instructions.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2020 Resolved
Observed vessel using a 100 ft length fire hose. Vessel better suited to use a shorter fire hose. Provide a 50 ft length fire hose as per regulations.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Replaced 100ft length fire hose.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 November 2019 Resolved
Manual override for the pre-engineered system is required. Manual override was not operable. Fix manual override function.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 26 November 2019 Resolved
compartments required to have a high level alarm must both be audible and visual. Visual alarm at the operating station was not functioning. Repair or replace light source.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2019
Fire Fighting › Fire Pumps › Pressure
Issued 17 November 2005 Resolved
Prove proper operations on fire pump and fire pump gauge
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2005
Resolution: Tested sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 17 November 2005 Resolved
Provide proper amount of lifejackets to accomadatetotal number of persons allowed indicated on COI
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2005
Resolution: Corrected after deficiency was written
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 17 November 2005 Resolved
Provide required servicing report from qualified servicing facility regarding inspection, maintenance procedures and hydrostatic pressure tests for all portable fire fighting extinguishers as per 46CFR176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 17 November 2005 Resolved
Prove proper operation of aft high water indicator visual alarm.
Due 1 December 2005
Resolved 29 November 2005
Resolution: Test sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 17 November 2005 Resolved
Provide navigation publications on board IAW 46CFR184.420
Due 1 December 2005
Resolved 29 November 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 November 2005 Resolved
Provide Protective Cover to Waterlight.
Due 1 December 2005
Resolved 29 November 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 November 2005 Resolved
Properly label child lifejacket compartment with correct number.
Due 1 December 2005
Resolved 29 November 2005
Engineering › Compressed Air System (control) › Piping
Issued 17 November 2005 Resolved
Properly secure engine exhaust piping.
Due 1 December 2005
Resolved 29 November 2005
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 17 November 2005 Resolved
Properly secure battery box
Action required: 705 - Other - as specified
Due 1 December 2005
Resolved 29 November 2005
Engineering › Bilge Water Management System › Valve
Issued 17 November 2005 Resolved
Provide fitting with positive closing valves on the submersible bilge pump for engineroom
Due 1 December 2005
Resolved 29 November 2005
Fire Fighting › Fire Pumps › Pressure
Issued 23 November 2004 Resolved
Vessel's fire pump is not discharging the proper amount of water pressure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 November 2004
Fire Fighting › Fire Pumps › Pressure
Issued 23 November 2004 Resolved
The fire pump pressure gauge is inop.
Condition: Improper/Lack of Maintenance
Due 23 November 2004
Resolved 23 November 2004
Fire Fighting › Ventilation Systems › Fans
Issued 23 November 2004 Resolved
Supply fan for the Machinery space is inop.
Condition: Improper/Lack of Maintenance
Due 1 December 2004
Resolved 23 November 2004
Engineering › Bilge Water Management System › Piping
Issued 12 September 2004 Resolved
All Water Taxi vsl's must be fitting with postive closing valves on the submergable bilge pumps.
Condition: Improper Installation
Due 1 January 2005
Resolved 27 February 2019
Resolution: Completed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 August 2004 Resolved
Vsl failed Simplified Sub-division, provide a proposal to bring all the vessels in compliance. The proposal is due no later than 01 September 2004 for work to be completed on all vessels no later than 01 January 2005.
Condition: Improper Installation
Due 1 September 2004
Resolved 27 February 2019
Resolution: Completed.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 24 September 2003 Resolved
Provide documentation of annual test of fixed fire fighting system.
Action required: 705 - Other - as specified
Due 24 October 2003
Resolved 3 October 2003
Engineering › Diesel Engine (propulsion-electric)
Issued 24 September 2003 Resolved
Repair/replace ventilation system fan to Engine Room.
Action required: 705 - Other - as specified
Due 24 October 2003
Resolved 11 December 2003
Resolution: Fan was renewed.
Fire Fighting › Fixed Fire Detection System
Issued 24 September 2003 Resolved
Provide documentation of testing of smoke detection system.
Action required: 705 - Other - as specified
Due 24 October 2003
Resolved 11 December 2003
Resolution: Tests performed and found sat.

Casualty record · 1

11 December 2005Routine · role: Involved in a Marine Casualty · activity 2563243
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.