Records from 1998 to 2009. Most recent: inspection, 5 May 2009.
Documentation record
Registered dimensions (L × B × D)64.5 ft × 16.1 ft × 7.4 ft
Registered tonnagegross 61 / net 42
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMOJEAN & ERICSON BOAT · TACOMA WA, UNITED STATES · built 1935
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 10 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
42 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
5 May 2009
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3468218
17 May 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2933293
1 May 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2653662
12 May 2005
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2355822
8 February 2005
Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2288887
28 April 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2055562
30 April 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1783130
24 April 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1608683
22 January 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1480347
1 May 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426588
5 May 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1443010
29 April 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1051546
29 August 1998
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 820510
29 August 1998
Hull Examination · Plan Review "T" Boat · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399088
Lifesaving › Inflatable Liferafts › Servicing
Issued 24 May 2007
Resolved
Must provide properly serviced liferaft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2007
Resolved 8 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2007
Resolved
Properly secure engine room overhead wiring.
Due 8 June 2007
Resolved 8 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 24 May 2007
Resolved
Demonstrate proper operation of lazerette bilge alarm.
Due 8 June 2007
Resolved 8 June 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 May 2006
Resolved
Ring Buoy lifeline missing.
Due 17 May 2006
Resolved 12 May 2006
Resolution: New buoyant lifeline attached on 12 May 06
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 May 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2006
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2006
Resolved
Engine room had dead end wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 May 2006
Resolution: Dead end wiring in engine room removed.
Construction/Loadline
Issued 5 May 2000
Resolved
VISUAL AND AUDIBLE BILGE HIGH LEVEL ALARM NOT OPERATING. CORRECT AND ENSURETHE PROPER OPERATION OF ALL BILGE ALARMS.
Condition: Unknown
Due 5 May 2000
Resolved 7 June 2000
Lifesaving
Issued 5 May 2000
Resolved
INFLATABLE LIFERAFT IS PASSED ANNUAL SERVICING DATE. HAVE LIFE RAFT SERVICED AND PRIOR TO CARRING PASSENGERS FOR HIRE OUTSIDE OF LAKE WASHINGTON OR LAKE UNION.
Condition: Unknown
Due 5 May 2000
Resolved 7 June 2000
Fire Fighting
Issued 29 August 1998
Resolved
Provide proper system for engineroom protection.
Condition: Unknown
Due 29 May 1999
Resolved 19 July 1999
Engineering
Issued 29 August 1998
Resolved
Provide proper impingment bowl for fuel filters.
Condition: Unknown
Due 29 May 1999
Resolved 19 July 1999