← All vessels
ENTICER
Passenger (Inspected) · Passenger Ship class · Built 1930s · USCG Northeast District (CGD-NE) · Other hulls named ENTICER
ENTICER is a 1935 passenger vessel (inspected). The Coast Guard has recorded 88 inspections since 1988, most recently in September 2025, along with 116 deficiencies and 1 casualty investigation in 2019.
Records from 1988 to 2025. Most recent: inspection, 2 September 2025.
- Built
- 1935
- Last inspected
- 2 September 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 116 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2019
Identity
234490
WDL3141
59377
Flag
UNITED STATES
368118710
Maury page id
psix-59377
Inspections, by type
…with no type recorded18
Years with a record
35 calendar years (1988–2025)
The 88 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)74.9 ft × 18.0 ft × 8.3 ft
Registered tonnagegross 78 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMATHIS YACHT BUILDING · CAMDEN, NJ, UNITED STATES · built 1935
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT, RI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationValid · issued 10 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL3141MMSI 368118710 · active · compulsorily equipped · granted 30 October 2019, expires 30 October 2029
WDE7520MMSI 368369000 · expired · compulsorily equipped · granted 7 February 2009, cancelled 13 April 2019
WCY6829MMSI 366755610 · expired · compulsorily equipped · granted 8 September 1998, cancelled 8 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 88
2 September 2025
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8229887
14 November 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8031869
17 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8004985
31 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7775038
6 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7656465
3 June 2022
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7452751
14 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7301809
21 April 2021
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7179873
23 October 2020
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7082773
14 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7060743
1 November 2019
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6842201
3 July 2019
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6734472
3 July 2019
Type not recorded
No type recorded · Station Castle Hill · USCG Northeast District (CGD-NE) · Activity 6744819
3 July 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6762093
21 February 2019
Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6713011
20 August 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6517652
19 June 2017
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6176681
13 March 2017
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6101062
13 October 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6014569
3 January 2016
Type not recorded
No type recorded · Station Key West · USCG Southeast District (CGD-SE) · Activity 5819735
7 December 2015
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5776659
13 October 2015
Hull Examination · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5741762
10 October 2014
DAPI Audit · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4983900
14 February 2012
Inclining Experiment
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4243966
2 July 2009
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3521114
4 June 2008
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3227811
8 May 2008
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3201794
1 May 2007
Administrative Inspection · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2918867
7 March 2007
Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2884809
23 February 2007
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2876440
11 July 2006
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2709369
25 July 2005
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2430769
13 June 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2424000
16 August 2004
Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2167293
1 June 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2085607
3 November 2003
Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1930659
16 April 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1774653
14 July 2002
Type not recorded
No type recorded · Station Jonesport · USCG Northeast District (CGD-NE) · Activity 1646272
24 June 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1635436
24 May 2002
Inclining Experiment · COI Inspection · Hull Examination
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1615252
3 January 2001
Plan Review "T" Boat
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059806
17 July 2000
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 819821
11 July 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 819952
7 July 2000
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 820265
23 May 2000
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1453762
22 November 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 810324
27 September 1999
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1034541
21 July 1999
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1471720
12 May 1999
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1365248
6 October 1998
Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 801026
31 August 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 798318
27 August 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1120198
18 July 1997
Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1443892
27 November 1996
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1396625
14 August 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1093018
24 July 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1385790
12 June 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 774353
29 May 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1084352
16 May 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082500
24 January 1996
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 878627
3 November 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1374428
27 July 1995
MARPOL Annex V Examination · Excursion Permit · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192669
10 May 1995
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909876
3 April 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1468786
29 August 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 867140
19 August 1994
Examination of Repairs · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1175623
10 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853983
24 February 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840366
24 February 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1162261
29 January 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132619
14 August 1992
Excursion Permit
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1247709
20 July 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 214812
1 July 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261511
30 June 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945198
8 May 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947062
22 April 1992
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955556
25 September 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246917
12 April 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 930147
26 March 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 913531
21 November 1990
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1225655
7 June 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914321
15 May 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220040
19 April 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927387
28 December 1989
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1229948
1 May 1989
Hull Examination · Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1037894
23 February 1989
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1350465
1 June 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1197918
7 March 1988
Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 992224
Deficiency record · 116
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 September 2024
Resolved
Each vessel constructed of wood certificated to operate on a limited coastwise route in cold water must be provided with inflatable buoyant apparatus of an aggregate capacity that will accommodate at least 67% of the total number of persons permitted on board; current IBA has not been serviced. Vessel limited to 3 miles from shore till 01 OCT 2024 when warm water season ends. As of 01 OCT 2024, vessel limited to 1 mile from shore.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 September 2024
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. High water alarm panel is currently inoperable and needs to be repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2024
Resolved
A vessel of more than 65' must carry a minimum of 3 life buoys of not less than 24" in diameter. At least one life buoy must carry one floating waterlight, unless limited to daytime operations. Vessel's waterlight is inoperable. Repair or replace waterlight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 September 2024
Resolved
Each watertight bulkhead must be of sufficient strength
to be capable of remaining watertight with a head of water to the top of the bulkhead. Gasket in the watertight door in the engine space is misaligned. Re-align or replace gasket to make space watertight.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 September 2024
Resolved
On a vessel of more than 65' in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Speaker on aft deck is currently being painted and needs to be re-installed and tested.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2024
Resolved
On a vessel of more than 65' in length, the minimum capacity of the fire pump must be 50 gpm at a pressure of not less than 60 psi at the pump outlet. The pump outlet must be fitted with a pressure gauge.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 September 2024
Resolved
A vessel must carry adequate and up-to-date:
charts, U.S. Coast Pilot, CG Light List, tide tables and current tables. Vessel needs to provide up to date pubs and charts.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 August 2023
Resolved
Each vessel constructed of wood certificated to operate on a limited coastwise route in cold water must be provided with inflatable buoyant apparatus (IBA) that will accommodate 67% of the total number of persons permitted on board. IBA is currently being serviced and not on board the vessel. Vessel limited to three miles of land in warm water months (July 1 - September 30) and within 1 mile of shore during cold water months (October 1 - June 30) till IBA has been properly serviced and placed on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2022
Resolved
A vessel must have one or more ring life buoys as follows: (3) A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter.
Provide two serviceable life buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 June 2022
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead.
Ensure above engine room watertight door that the watertight bulkhead is watertight.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2022
Resolved
Rules in this subpart (Rules 20-31) (§§ 83.20 through 83.31) shall be complied with in all weathers.
Ensure Starboard navigation light is operational.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 June 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Ensure first-aid kit is stowed in a watertight container.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 June 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations.
Determine cause of port shaft noise at 1200-1400RPM.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 June 2022
Resolved
Penetrations of required watertight decks and bulkheads by any rigid plastic pipe are prohibited unless the following requirements are met:One or more metallic shutoff valves must be installed adjacent to the fitting in one of the following ways:
(A) Only one metallic shutoff valve must be installed if it is operable from above the bulkhead deck;
(B) If two metallic shutoff valves are installed, one on either side of the bulkhead, they need not be operable from above the bulkhead deck provided immediate access to both is possible;
Plastic pipe penatrations centerline, port and starboard side of forward engine room bulkhead shall have metallic shut-off valves. By next Drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2021
Resolved
An adult life jacket must be provided for each person carried onboard the vessel. COI requires 65 adult life jackets, there are only 56 onboard. Vessel is restricted
to 53 passengers and 3 crew until 9 more placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 September 2021
Resolved
Each vessel on a limited coastwise route in cold water must be provided with an inflatable buoyant apparatus to accommodate 67% of persons onboard. IBA being serviced. Vessel is restricted to operations within 3NM of shore until the IBA is back onboard or until 30 Sept 2021.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 September 2021
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a
chemical test for dangerous drugs for that employer. All
employees have not completed pre-employment drug testing
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 September 2021
Resolved
A marine employer whose vessel is involved in a casualty shall be able to conduct alcohol testing within 2 hours. Vessel does not have enough alcohol swabs onboard.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 September 2021
Resolved
Each vessel that operates beyond 3NM from shore must
have a Category 1, 406 MHz EPIRB installed. EPIRB does
not have a NOAA registration associated with it.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2021
Resolved
A vessel must carry one floating waterlight unless it is
limited to daytime operations. Vessel waterlight battery
is expired. Vessel is restricted to daylight operations.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 14 September 2021
Resolved
Prior to getting underway on a voyage or as soon as
possible thereafter, the master shall make a suitable
announcement to the passengers. Safety orientation sheet
does not have an accurate location for life jackets.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 14 September 2021
Resolved
A vessel more than 65ft must have a fixed installation
PA system audible throughout accommodation spaces. PA
system not audible in accommodation spaces.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 September 2021
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screen shall consist of a single screen of corrosion resistant wire of at least 30X30 mesh and shall be of such size and design as to prevent reduction in the net cross-sectional area of the vent pipe and permit cleaning or renewal. No flame screens found.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 September 2021
Resolved
Each port light with the sill located below the margin line must have a hinged inside dead cover. Vessel does not have dead covers onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 14 September 2021
Resolved
A vessel must comply with applicable requirements for any radio as set forth in 47 CFR 80. Each ship transporting more than six passengers for hire equipped with a radiotelephone station must carry a radio operator who holds a marine radio operator permit or higher class license where station power does not exceed 250 watts carrier power or 1500 watts peak envelope power. Vessel master does not have a marine radio operator permit.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 14 September 2021
Resolved
A vessel must comply with the requirements for station license and installation by the FCC. Vessel does not have the correct MMSI number entered in their radio.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2021
Resolved
All unfired pressure vessels must be installed to the satisfaction of the OCMI. Provide manufacturer documentation to ensure pressure vessel meets ASME or other approved standard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 September 2021
Resolved
Each EPIRB must be tested monthly and this test shall be logged. No EPIRB monthly tests have been logged.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 September 2021
Resolved
A vessel on a limited coastwise route must carry six red hand flares and six orange smoke signals. Red hand flares may be substituted for orange signals. Vessel has 11 flares. Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 October 2020
Resolved
Wooden vessel is due for fasener pull IAW COI. Complete fasener pull prior to carrying passengers to the satisfaction of the attending Coast Guard Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2020
Resolved
Openings in multiple engine room power panels exposing current carrying wiring poses an electrical hazard to the crew. Properly enclose power panels to the satisfaction of the attending Coast Guard Marine Inspector (CGMI). 46 CFR 111.05-15 Old-J.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2020
Resolved
Engine room light wired using wire nuts. Make splice using mechanical type connector or place in an enclosure to the satisfaction of the attending CGMI. 46 CFR 111.50-1 Old-J
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2020
Resolved
Extension cord used to plug in additional outlets and is not suitable for a fixed system. Remove or properly wire additional receptacles through breaker panel to the satisfaction of the attending CGMI. 46 CFR 111.60-5 Old-J
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 October 2020
Resolved
Engine room has multiple dead end wires. Remove wiring not in use or place in an enclosure to the satisfaction of the attending CGMI. 46 CFR 111.05-15 Old-J
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 October 2020
Resolved
Upper passenger deck not labeled with maximum number of passengers. Label the number of passengers allowed on the upper deck with at least one inch numbers and letters at the entranceway to that deck.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2019
Resolved
Missed 3rd annual inspection, past 90 days on annual inspection due 19 sep 2019.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 3 July 2019
Resolved
Provide repair proposal for damage on STBD side of hull IWO bow under third port hole aft, to the satisfaction of Marine Inspector prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 February 2019
Resolved
Strut attachment loose, provide repair proposal.
Communications › Alarms/Indicators › High Water Alarm
Issued 19 June 2017
Resolved
Repair fwd bilge alarm.
Communications › Audible Communications › Bell
Issued 19 June 2017
Resolved
Provide 12" bell as per nav rules.
Communications › Radio Communications › EPIRB
Issued 19 June 2017
Resolved
Properly mount EPIRB.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 June 2017
Resolved
Repair or replace waterlight. Housing cracked.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2017
Resolved
Replace expired medication.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 June 2017
Resolved
Provide alcohol test strips.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 13 October 2016
Resolved
Prove proper operation of fixed fire systems abiliity to secure all engines in space and for override feature to function properly.
Communications › Radio Communications › VHF Radiotelephone
Issued 13 October 2016
Resolved
Properly configure radio to provide location information.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 October 2016
Resolved
Renew expired items in first aid kit.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 October 2016
Resolved
Provide current Safety radio certificate.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 October 2015
Resolved
Battery expired Sept 2015.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 16 October 2015
Resolved
Last servicing June 2014.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 October 2014
Resolved
Watertight door to engine room does not seal due to lower hatch bar not able to connect with hull frame.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 10 October 2014
Resolved
Hydrostatic release unit was expired.
Communications › Radio Communications › EPIRB
Issued 10 October 2014
Resolved
EPIRB Hydrostatic release was expired.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 10 October 2014
Resolved
Ventillation and engine/generator shut downs are improperly placed within the engine room. Owner will make proposal to OCMI for clarification of shut down operations.
Stability › Watertight Integrity › General
Issued 10 October 2014
Resolved
Rudder packing was loose and allowing significant quantities of water into the lazarette space.
Lifesaving › Lifebuoys › Serviceable
Issued 8 May 2008
Resolved
Install retro material on liferings and replace grab line on starboard lifering.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 8 May 2008
Resolved
Install shutdown to port generator.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 8 May 2008
Resolved
Need to add person qaulified in CPR/First Aid.
Lifesaving › Hand Flares › Quantity
Issued 8 May 2008
Resolved
Need to 6 flares to meet limited coastwise route.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 8 May 2008
Resolved
Make emergency escape hatch operational when carrying passengers. Currently have hatch covered with canvas.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 7 March 2007
Resolved
Provide draft marks in accordance with 46 CFR 185.602.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 7 March 2007
Resolved
Remove excess oil and water from bilge and make available for inspection.
Stability › Watertight Integrity › General
Issued 7 March 2007
Resolved
Make all thru hull valves available for inspection.
Fire Fighting › Fire Pumps
Issued 28 June 2002
Resolved
Provide isolation valve for fixed attached fire pump to prevent water recirculation and improve pump output. LEGACY COMPONENT DESC: Pressure
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 May 2002
Resolved
Placard fire station and portable extinguisher in main salon (not visable). LEGACY COMPONENT DESC: Marking
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 May 2002
Resolved
Placard all portable fire extinguishers in accommodation spaces. (not visable) LEGACY COMPONENT DESC: Marking
Engineering
Issued 21 May 2002
Resolved
Add detail locations of thru-hull valves on system drawing.
Stability › Watertight Integrity
Issued 21 May 2002
Resolved
Adjust engine room watertight door.
Engineering
Issued 21 May 2002
Resolved
Provide reach rod for ball valves in engine room that can not be reached.
Navigation › Piloting/Steering
Issued 21 May 2002
Resolved
Swing compass after all electronics are operational. LEGACY COMPONENT DESC: Magnetic Compass
Stability › Incline Test
Issued 21 May 2002
Resolved
Provide results of incline stability test for review by a CG Marine Inspector.
Electrical › Lighting (service)
Issued 21 May 2002
Resolved
Install dead light covers
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 21 May 2002
Resolved
Mark emergency escape in forward compartment and provide escape ladder
Engineering › Bilge Water Management System
Issued 21 May 2002
Resolved
Provide a portable bilge pump
Documentation › Markings/Placards
Issued 21 May 2002
Resolved
Post stablity letter, emergency instructions card, oil pollution placard, MARPOL placard, and EAP information for crew
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 21 May 2002
Resolved
Mount all portable fire extinguishers throughout vessel LEGACY COMPONENT DESC: Mounting Bracket
Fire Fighting › Fire Pumps
Issued 21 May 2002
Resolved
Lable overboard discharge valve "to be left open while fire pump is operating"
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 May 2002
Resolved
Install guard on test switch in pilothouse LEGACY COMPONENT DESC: Operating Controls
Electrical
Issued 21 May 2002
Resolved
Seal all wire transits that pass between watertight bulkheads including transit over engine room door
Accommodation/Occupational Safety › Occupational Safety
Issued 21 May 2002
Resolved
Mount portable flashlights at pilothouse and engine compartment LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Lifesaving › Lifebuoys
Issued 21 May 2002
Resolved
Mount all ring lifebouy's around vessel LEGACY COMPONENT DESC: Stowage
Electrical › Lighting (service)
Issued 21 May 2002
Resolved
Mount all light switches in main salon
Electrical
Issued 21 May 2002
Resolved
Complete wiring in all heads that passengers have acess to
Personnel › Training
Issued 21 May 2002
Resolved
Conduct drills under the supervision of Coast Guard personnel (underway fire and man overboard)
Accommodation/Occupational Safety › Occupational Safety
Issued 21 May 2002
Resolved
Provide lifeline across bow area LEGACY COMPONENT DESC: Lifeline
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 10 May 2002
Resolved
Contact local OCMI prior to installing any carpets or furnishings on board.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 May 2002
Resolved
Discuss portable fire extinguisher sizes with local OCMI that are mounted throughout the vessel.
Lifesaving
Issued 23 May 2000
Resolved
PROVIDE EMERGENCY LIGHTING FOR CREW AND PASSENGER ACCOMODATION SPACES BELOWTHE MAIN DECK.
Electrical
Issued 21 July 1999
Resolved
PROVIDE AS BUILT PLANS FOR GENERATORS AND DISTRIBUTION PANNEL OF PLAN APPROVAL.
Construction/Loadline
Issued 14 August 1996
Resolved
REPAIR/RENEW FIRST/SECOND FL TIMBER IN KIDDIE S/R STBD SIDE, FLOOR TIMBERS AFT S/R #1-#3, FWD OF AFT BHLKHD & KNEE AT FIRST FRAME FWD, NEAR BUTT BLOCKPORT SIDE NEAR SHOWER SUMP
Construction/Loadline
Issued 14 August 1996
Resolved
RENEW AS ORIGINAL AREA OF KEEL AT AFT S/R, AFT BHLKHD AND STEERING COMPT.
Accommodation/Occupational Safety
Issued 24 July 1996
Resolved
PROPERLY INSTALL RAILS TO THE HEIGHT REQUIRED BY 46 CFR 177.900(d), (i).
Construction/Loadline
Issued 24 July 1996
Resolved
INSTALL ISOLATION VALVE BETWEEN BILGE AND FIRE MAIN SYSTEM.
Construction/Loadline
Issued 24 July 1996
Resolved
REPAIR AND DEMONSTRATE ENGINE ROOM WATER TIGHT DOOR INDICATOR.
Construction/Loadline
Issued 24 July 1996
Resolved
DEMONSTRATE BILGE SYSTEM.
Engineering
Issued 24 July 1996
Resolved
PROPERLY REINSTALL FUEL LINES ON RACOR FILTERS IAW 46 CFR 182.720.
Engineering
Issued 24 July 1996
Resolved
PROPERLY ADJUST FUEL SHUT OFF VALVE AND DEMONSTRATE.
Documentation
Issued 29 May 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety
Issued 16 May 1996
Resolved
Disconnect discharge piping for heads not properly installed.
Construction/Loadline
Issued 16 May 1996
Resolved
Repair/Renew items as follows: 1st & 2nd floor timber in kiddie strm stbd, floor timbers aft stateroom-stbd 1st & 3rd fwd of aft blkhd & knee at 1st frm fwd, butt block port side near shower sump._x001C_
Construction/Loadline
Issued 16 May 1996
Resolved
Renew in like kind as original, area of keel at aft strm, aft bulkhead & steering compartment.
Engineering
Issued 27 July 1995
Resolved
PRIOR TO OPERATION, REPLACE FUEL TANK FLAME SCREEN WITH 30X30 MESH SCREEN.
Documentation
Issued 29 August 1994
Resolved
PROVIDE DOCUMENTATION THAT VESSEL CREW IS ENROLLED IN A DRUG TESTING PROGRAM AS REQUIRED BY 46 CFR PART 16.
Lifesaving
Issued 22 April 1992
Resolved
PROVIDE PROPER OPERATION OF BILGE ALARM SYSTEM.
Lifesaving
Issued 22 April 1992
Resolved
REPLACE DETERIORATED LINE ON STBD RING BUOY .
Lifesaving
Issued 22 April 1992
Resolved
MARK PORTSIDE RING BUOY WITH VESSEL'S NAME.
Deck/Cargo
Issued 22 April 1992
Resolved
PROPERLY ATTACH WIRE RUN IN FORWARD HEAD FOR DECK CAPSTAN.
Engineering
Issued 19 April 1990
Resolved
RENEW MDE SALT WATER SUCTION HOSES WITH USCG APPROVED SUCTION HOSES.
Navigation
Issued 19 April 1990
Resolved
PROVIDE CURRENT COPIES OF NAVIGATION RULES OF THE ROAD, TIDES AND CURRENTS.
Engineering
Issued 19 April 1990
Resolved
INSTALL FUEL TANK, VENT LINES IN ACCORDANCE WITH 46 CFR 182.20-35.
Construction/Loadline
Issued 1 May 1989
Resolved
REMOVE ALL SUSPECT AREAS AS MARKED THAT SHOW EVIDENCE OF MARINE BORER INFESTATION. AREA TO INCLUDE PLANKS ON PORT AFT QUARTER AND STBD AFT QUARTER.
Construction/Loadline
Issued 1 May 1989
Resolved
MAKE PROPER REPAIRS TO ALL FRAMES RHAT SHOW EVIDENCE OF ROT OR WASTAGE.
Construction/Loadline
Issued 1 May 1989
Resolved
REPLACE AREAS OF WORM SHOE THAT SHOW EVIDENCE OF WORM INFESTATION.
Documentation
Issued 23 February 1989
Resolved
POST STABILITY LETTER IN WHEELHOUSE.
Fire Fighting
Issued 23 February 1989
Resolved
REMOVE UNUSED CO2 EXTINGUISHING SYSTEM.
Documentation
Issued 23 February 1989
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION, FCC MARINE OPERATOR'S PERMIT, AND VALID FCC COMMUNICATIONS ACT SAFETY CERTIFICATE.
Casualty record · 1
3 July 2019Routine · role: Involved in a Marine Casualty · activity 6762093
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.