ASKABAT

ASKABAT is a 2002 freight ship. The Coast Guard has recorded 20 inspections since 2002, most recently in February 2011, along with 11 deficiencies and 11 operational controls.

Records from 2002 to 2011. Most recent: operational control imposed, 23 February 2011.

Built
2002
Last inspected
23 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8811405 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
593988
Flag
TURKEY
—
Maury page id
psix-593988

Inspections, by type

…with no type recorded12
Years with a record 8 calendar years (2002–2011)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it6593 - Convention (Subpart B), Net Ton
18855 - Dead Weight, Ton
25656 - Displacement, Ton
12930 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

23 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3951049
7 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3940849
2 February 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3937949
19 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3895075
12 July 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3531960
4 February 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3141507
29 January 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3138353
30 May 2007 ISPS II Exam · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2946012
10 November 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2532513
17 October 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2516607
27 July 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2441576
21 July 2005 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2433608
18 July 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2431703
14 November 2003 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1947521
13 November 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1955424
4 November 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1943131
28 April 2003 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1782261
25 April 2003 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1780410
13 January 2003 Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1729805
14 September 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1675993

Deficiency record · 11

Engineering › Steering Gear System › Actuator
Issued 27 July 2005 Resolved
27JUL2005 VSL SUFFERED STEERING FAILURE WHILE TRANSITING HOUSTON SHIP CHANNEL. ISSUED OP CONTROL. VSL TO MAKE REPAIRS TO SATISFACTION OF CERTIFICATE ISSUING AUTHORITY PRIOR TO ENTERING PORT.
Action required: 705 - Other - as specified
Resolved 27 July 2005
Resolution: vsl submitted report to satisfactory repairs of steering.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 14 November 2003 Resolved
Flammable paints and solvents stored in deck stores, port-side aft, main deck. Compartment also has electrical equipment & switch boxes (exposed wiring inside). Remove prior to sail.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 14 November 2003
Resolved 14 November 2003
Resolution: Corrected prior to USCG inspectors departing the port.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 November 2003 Resolved
Have Class Society examine & approve Fire Control Plan, specifically the entrance to the paint locker that is not shown on plan.
Condition: Placed in Improper Service
Due 13 December 2003
Resolved 21 July 2005
Resolution: NEWMS Boarding Team observed Fire Control Plan in proper order.
Operations/Management
Issued 14 September 2002 Resolved
CLASS ISSUING INTERIM (ABS) MUST PROVIDE STATEMENT OF SIGNIFICANT PROGRESS TOWARDS ADEQUATE SAFETY MANAGEMENT SYSTEM.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 September 2002
Resolved 13 January 2003
Resolution: Received proper documentation satisfying requirement.
Fire Fighting › Firemans Outfit
Issued 14 September 2002 Resolved
ENTIRE FIREMAN'S OUTFIT WASHED OVERBOARD IN HEAVY WEATHER.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2002
Resolution: NEW FIREMANS OUTFIT RECEIVED ON BOARD.
Lifesaving › Inflatable Liferafts › Container Construction
Issued 14 September 2002 Resolved
PORT AND STARBOARD AFT LIFERAFT CASINGS HAD HOLES IN THEM.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2002
Resolution: VANE BROTHERS REPLACED BOTH WITH TEMP. LIFERAFTS WHILE PERMANENT RAFT CASINGS WERE BEING REPAIRED.
Lifesaving › Lifebuoys
Issued 14 September 2002 Resolved
VESSEL MISSING 2 LIFERINGS.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2002
Resolution: BOTH LIFERINGS REPLACED.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 September 2002 Resolved
SELF INGNITING LIGHTS ON 3 LIFERINGS NOT OPERABLE. SELF IGNITING LIGHT ON 1 LIFERING WAS MISSING.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2002
Resolution: CORRECTED.
Navigation › Piloting/Steering › Marine Charts
Issued 14 September 2002 Resolved
MISSING ADM. CHART #2605.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2002
Resolution: RECEIVED NEW CHART ON BOARD
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 September 2002 Resolved
MISSING BA COAST PILOT VOL. 69.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2002
Resolution: RECEIVED ON BOARD PTD.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 14 September 2002 Resolved
NO COPY OF U.S. INLAND NAV. RULES ON BOARD.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 September 2002
Resolution: RECEIVED PRIOR TO DEPARTURE.