← All vessels
VICKIE TIDE
VICKIE TIDE is a 2003 offshore supply vessel. The Coast Guard has recorded 20 inspections since 2003, most recently in June 2017, along with 13 deficiencies and 3 casualty investigations between 2004 and 2005.
Records from 2003 to 2017. Most recent: inspection, 15 June 2017.
- Built
- 2003
- Last inspected
- 15 June 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2004–2005
Identity
1133383
9269855 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB2267
594382
Flag
VANUATU
369211000 (licence lapsed)
Maury page id
psix-594382
Inspections, by type
…with no type recorded4
Years with a record
8 calendar years (2003–2017)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it494 - Convention (Subpart B), Gross Ton
197 - Regulatory (Subpart C or D), Gross Ton
148 - Convention (Subpart B), Net Ton
134 - Regulatory (Subpart C or D), Net Ton
251 - Displacement, Ton
197 - Regulatory (Subpart C or D), Gross Ton
148 - Convention (Subpart B), Net Ton
134 - Regulatory (Subpart C or D), Net Ton
251 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDB2267MMSI 369211000 · cancelled · compulsorily equipped · granted 13 November 2002, cancelled 10 November 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 20
15 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6176569
18 February 2009
Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3419503
28 January 2008
Internal Structural Exam · Cargo Tank Internal · Examination of Repairs · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3137404
6 March 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2891325
23 January 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2571700
20 January 2006
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2569676
1 July 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2432181
15 June 2005
MTSA/ISPS Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2391256
26 May 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2386058
6 April 2005
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2327643
16 March 2005
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2311353
31 March 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2035265
27 January 2004
Re-Inspection · Administrative Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1993644
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971086
12 September 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1903432
2 June 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1825628
12 March 2003
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1758215
11 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1755956
31 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1738058
15 January 2003
Internal Structural Exam · Initial Construction-Excluding Oversight · Construction Oversight · Hull Examination · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1713955
Deficiency record · 13
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 27 January 2004
Resolved
Install shaft speed and direction indicators IAW 46 CFR 113.37.
Documentation
Issued 15 January 2003
Resolved
Provide for review a procedure for tests to be conducted on automated equipment by the operator and the Coast Guard to comply with 46 CFR 127.110 of Subchapter "L" as required by 46 CFR 130.480. LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide for review a detailed operations manual that describes the operation and indicates the location of each system installed to comply with 46 CFR Subchapter "L" Part 130 as required by 46 CFR 130.480(e).
LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide Coast Guard approved plans with approval letter for fixed fire suppression system as required by 46 CFR 127.110(d)(2)(ii). LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide Coast Guard approved propulsion control system drawing and approval required by 46 CFR 127.110(d)(4).
LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide approved steering and steering control system drawings and approval letter as required by 46 CFR 127.110(d)(3) demonstrating compliance with 46 CFR 130.140.
LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
As required by 46 CFR 127.110(f), where automated systems are provided to replace specific personnel in control and observation of the propulsion systems and machinery spaces, plans shall be submitted to the CG Marine Safety Center to demonstrate compliance with 46 CFR Subchapter "L", part 130, LEGACY COMPONENT DESC: Plans
Communications › Audible Communications
Issued 15 January 2003
Resolved
A vsl must not have more than one other contact maker that operates the general emergency alarm system in addition to the req contact maker in the nav bridge as per 46 CFR 113.25-5. Make the necessary changes to the vsl's general emergency alarm system to comply with 46CFR113.25-5 as noted above. LEGACY COMPONENT DESC: General Emergency Alarm
Documentation
Issued 15 January 2003
Resolved
Provide a copy of the U.S. registered professional engineer's (PE) certified plans and analysis required by 46 CFR 54.01-5(e), along with the manufacture's data report (ASME form U-1A) required by UG-120 of the ASME Code. LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide approved plans and review letters for ventilation arrangement demonstrating compliance with 46 CFR 127.250, 46 CFR 127.260 and other applicable sections of 46 CFR Subchapter "L". LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide approved plans and review letters for rescue appliance davit and davit foundation for structural strength.
LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide revised fire control plan for review and approval as required by 46 CFR 127.110(a)(3) to verify compliance with 46 CFR 131.945.
LEGACY COMPONENT DESC: Plans
Documentation
Issued 15 January 2003
Resolved
Provide approved steering gear alarm plan(s) and review letter(s) demonstrating compliance with 46 CFR 130.140. LEGACY COMPONENT DESC: Plans
Casualty record · 3
31 March 2004Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 dead · activity 2035265
26 May 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2386058
1 July 2005Routine · role: Involved in a Marine Casualty · activity 2432181
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.