Records from 2003 to 2026. Most recent: inspection, 16 April 2026.
Inspection history · 18
16 April 2026
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8354232
14 May 2021
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7197055
22 April 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6668587
4 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6433568
6 July 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6199341
4 April 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6117736
19 October 2016
Simplified Stability Test · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6026505
2 March 2016
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5826068
5 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4809155
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200413
19 March 2009
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3435868
19 March 2008
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3167441
19 January 2007
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2858755
22 March 2006
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2607695
1 March 2005
Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2301218
1 March 2005
Hull Examination · Examination of Repairs · Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2579848
6 February 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2001771
27 February 2003
Initial Certification · Simplified Stability Test · Initial Construction-Excluding Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2001768
Lifesaving › Visual Distress Signals (General) › Expired
Issued 4 June 2018
Resolved
all flares were found to be expired. Vessel is restricted to short runs.
Action required: 705 - Other - as specified
Resolved 21 June 2018
Resolution: Vessel provided required flares.
Documentation › Logs/Records › Drug Test Records
Issued 4 June 2018
Resolved
vessel is to provide company policy for DAPI program.
Action required: 705 - Other - as specified
Due 4 June 2018
Resolved 4 June 2018
Resolution: vessel provided documentation
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 June 2018
Resolved
vessel is to install ground detection
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 9 August 2018
Resolution: Vessel installed ground detection and verified by MI.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 June 2018
Resolved
vessel is to install guard on moving parts located on stbd engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 21 June 2018
Resolution: Vessel installed guard over exposed rotating gear.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 4 June 2018
Resolved
vessel is to repair exhaust leak on stbd engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 21 June 2018
Resolution: Vessel repaired exhaust leak
Engineering › Bilge Water Management System › Pump
Issued 4 June 2018
Resolved
vessel is to repair bilge pump to meet the minimum of 10gpm
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 21 June 2018
Resolution: Vessels bilge system was repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 July 2017
Resolved
1. Replace masthead light. Restricted to daylight operations until fixed.
Action required: 705 - Other - as specified
Resolved 6 July 2017
Lifesaving › Lifebuoys › Serviceable
Issued 6 July 2017
Resolved
2. Re-stencil lifebuoys with vessel name and hailing port.
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 6 July 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 July 2017
Resolved
3. Submit servicing report for all fire extinguishing equipment.
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 11 July 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 March 2016
Resolved
KK01 - Repair bilge high level alarms to provide audiable alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 2 March 2016
Resolution: Repaired bilge alarm.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 2 March 2016
Resolved
KK02 - Conduct annual servicing of all portable fire extinguishing equipment and installed CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 7 March 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2016
Resolved
KK03 - Provide enclosures for all electrical connections in engine room.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 7 March 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 March 2016
Resolved
KK04 - Repair float light for ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 2 March 2016
Resolution: Replaced floa light.
Engineering › Fuel Oil Service System › Filter
Issued 2 March 2016
Resolved
KK05 - Provide drip pan for generator fuel filter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 2 March 2016
Resolution: replaced drip pan.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 March 2014
Resolved
Waterlight not connected with corrsion resistant clip.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 March 2014
Resolution: spliced in corrosion resistant clip.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 March 2014
Resolved
Posted EAP numbers were invalid.
Action required: 705 - Other - as specified
Due 12 March 2014
Resolved 5 March 2014
Resolution: Posted new EAP placard with operational numbers.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 March 2006
Resolved
Provide guards on main engine flywheels
Condition: Improper Installation
Due 22 April 2006
Resolved 30 January 2007
Navigation › Piloting/Steering › Compass Deviation Table
Issued 22 March 2006
Resolved
Provide compass deviation card at operating station.
Condition: Improper Installation
Due 22 April 2006
Resolved 30 January 2007
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 22 March 2006
Resolved
Provide day shapes and not under command lights.
Condition: Improper Installation
Due 22 April 2006
Resolved 30 January 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 22 March 2006
Resolved
Provide SOLAS approved retro reflective tape for lifefloat.
Condition: Improper Installation
Due 22 April 2006
Resolved 30 January 2007
Engineering › Fuel Oil Service System › Piping
Issued 22 March 2006
Resolved
Plug fuel manifold.
Condition: Improper Installation
Due 22 April 2006
Resolved 30 January 2007
Engineering › Fuel Oil Service System › Vent Pipe
Issued 22 March 2006
Resolved
Provide bonding wire for fuel fill and vent pipe.
Condition: Improper Installation
Due 22 April 2006
Resolved 30 January 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2006
Resolved
Provide metal banding to support wires in engine room.
Condition: Improper Installation
Due 22 April 2006
Resolved 30 January 2007
Engineering › Bilge Water Management System › Pump
Issued 22 March 2006
Resolved
Provide hand operated bilge pump.
Condition: Unknown
Due 22 April 2006
Resolved 30 January 2007
Engineering › Fuel Oil Service System › Piping
Issued 22 March 2006
Resolved
Fix fuel leak in piping in stern section.
Condition: Improper/Lack of Maintenance
Due 22 April 2006
Resolved 30 January 2007
Stability › Intact Righting Energy › General
Issued 22 March 2006
Resolved
Permanently remove awning.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2006
Resolved 30 January 2007
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 22 March 2006
Resolved
Provide an approved fire detection system for engine room.
Condition: Improper Installation
Due 22 April 2006
Resolved 22 March 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 March 2005
Resolved
Waiting on New COD for new owner and operator.
Due 5 April 2005
Resolved 6 February 2006