MAURY USCG vessel records
← All vessels

COLLEEN F

COLLEEN F is a 2002 industrial vessel. The Coast Guard has recorded 8 inspections since 2016, most recently in April 2026, along with 14 deficiencies and 1 casualty investigation in 2026.

Records from 2016 to 2026. Most recent: inspection, 16 April 2026.

Built
2002
Last inspected
16 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDC8891
595260
Flag
UNITED STATES
Maury page id
psix-595260

Documentation record

Registered dimensions (L × B × D)47.4 ft × 15.1 ft × 7.0 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJWP BOAT RENTALS INC · CHAUVIN, LA, UNITED STATES · built 2002
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 3 April 2026 · expires 31 May 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

WEEKS 118 Freight Barge · MISLE 53851 · 16 April 2026 · activity 8354232

Inspection history · 8

16 April 2026 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8354232
14 May 2021 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7197055
22 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6668587
4 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6433568
6 July 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6199341
4 April 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6117736
19 October 2016 Simplified Stability Test · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6026505
2 March 2016 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5826068

Deficiency record · 14

Lifesaving › Visual Distress Signals (General) › Expired
Issued 4 June 2018 Resolved
all flares were found to be expired. Vessel is restricted to short runs.
Action required: 705 - Other - as specified
Resolved 21 June 2018
Resolution: Vessel provided required flares.
Documentation › Logs/Records › Drug Test Records
Issued 4 June 2018 Resolved
vessel is to provide company policy for DAPI program.
Action required: 705 - Other - as specified
Due 4 June 2018
Resolved 4 June 2018
Resolution: vessel provided documentation
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 4 June 2018 Resolved
vessel is to install ground detection
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 9 August 2018
Resolution: Vessel installed ground detection and verified by MI.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 June 2018 Resolved
vessel is to install guard on moving parts located on stbd engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 21 June 2018
Resolution: Vessel installed guard over exposed rotating gear.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 4 June 2018 Resolved
vessel is to repair exhaust leak on stbd engine
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 21 June 2018
Resolution: Vessel repaired exhaust leak
Engineering › Bilge Water Management System › Pump
Issued 4 June 2018 Resolved
vessel is to repair bilge pump to meet the minimum of 10gpm
Action required: 705 - Other - as specified
Due 25 June 2018
Resolved 21 June 2018
Resolution: Vessels bilge system was repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 July 2017 Resolved
1. Replace masthead light. Restricted to daylight operations until fixed.
Action required: 705 - Other - as specified
Resolved 6 July 2017
Lifesaving › Lifebuoys › Serviceable
Issued 6 July 2017 Resolved
2. Re-stencil lifebuoys with vessel name and hailing port.
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 6 July 2017
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 6 July 2017 Resolved
3. Submit servicing report for all fire extinguishing equipment.
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 11 July 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 March 2016 Resolved
KK01 - Repair bilge high level alarms to provide audiable alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 2 March 2016
Resolution: Repaired bilge alarm.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 2 March 2016 Resolved
KK02 - Conduct annual servicing of all portable fire extinguishing equipment and installed CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 7 March 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2016 Resolved
KK03 - Provide enclosures for all electrical connections in engine room.
Action required: 705 - Other - as specified
Due 16 March 2016
Resolved 7 March 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 March 2016 Resolved
KK04 - Repair float light for ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 2 March 2016
Resolution: Replaced floa light.
Engineering › Fuel Oil Service System › Filter
Issued 2 March 2016 Resolved
KK05 - Provide drip pan for generator fuel filter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 March 2016
Resolved 2 March 2016
Resolution: replaced drip pan.

Casualty record · 1

16 April 2026Routine · role: Involved in a Marine Casualty · activity 8354232
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record