MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 26

STRETCH DUCK 26 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2002, most recently in August 2019, along with 13 deficiencies — 2 with no resolution recorded — and 1 operational control.

Records from 2002 to 2019. Most recent: inspection, 19 August 2019.

Built
1945
Last inspected
19 August 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

595361
Flag
UNITED STATES
—
Maury page id
psix-595361

Inspections, by type

…with no type recorded2
…past their stated due date1
Years with a record 15 calendar years (2002–2019)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

19 August 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6788046
28 June 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6761455
8 February 2019 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6622664
22 August 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6519684
21 March 2018 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6388125
3 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6331992
9 January 2017 Administrative Inspection · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6068132
23 March 2016 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5839279
19 January 2016 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5799906
26 July 2015 Deficiency Check · Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5197954
25 July 2015 Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5198560
19 March 2014 Administrative Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4916177
21 September 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4162270
3 November 2010 Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3877944
9 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653020
25 February 2009 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3426501
8 September 2008 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3320475
25 July 2007 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3005214
4 March 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2306681
22 June 2004 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2107874
1 December 2003 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1956830
24 March 2003 In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1778405
13 February 2003 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1740629
9 October 2002 Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1676355

Deficiency record · 13

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 February 2019 No resolution recorded
Demonstrate compliance with new Conditions of Operation listed on amended COI.
Action required: 17 - Rectify deficiencies prior to departure
Engineering › Bilge Water Management System › Piping
Issued 21 March 2018 No resolution recorded
Bilge piping and GPM rate is not in compliance with MSC Letter E1-0504811. Vessel to operate with 2 total hand bilge pumps and will require manning as appropriate. This is to be corrected by 2019 operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2018 — due date passed with no resolution recorded
Stability › Watertight Integrity › General
Issued 17 February 2016 Resolved
Make repairs to water ingress IWO installed steering box.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 3 March 2016
Resolution: Received email correspondence attesting to the satisfactory repairs.
Construction/Loadline › Hull › Bottom Plating
Issued 26 July 2015 Resolved
Submit repair proposal and effect repairs to damaged hull plating forward of the right front wheel well. All repairs are to be completed to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2015
Resolution: Conducted satisfactory float test.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 21 September 2011
Resolution: System modified to reduce maximum pressure to 15 psi or less excluding unfired pressure vessel from requirement.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 25 July 2007 Resolved
Properly install fire protection system to include CO2 nozzle in the engine compartment.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 August 2007
Resolved 24 August 2007
Resolution: Nozzle added to engine compartment.
Lifesaving › Lifebuoys
Issued 1 December 2003 Resolved
Install non corrosive clip on ring buoy lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 30 March 2004
Resolution: Clip installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 1 December 2003 Resolved
Label all child life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 30 March 2004
Resolution: All jackets labeled.
Lifesaving › Hand Flares
Issued 1 December 2003 Resolved
Provide a watertight, labeled, box for flares. LEGACY COMPONENT DESC: Storage
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 30 March 2004
Resolution: Watertight box, labeled provided.
Construction/Loadline › Penetrations
Issued 1 December 2003 Resolved
Install double hose clamps at each end of stuffing box. LEGACY COMPONENT DESC: Pipe Flange
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 January 2004
Resolved 30 March 2004
Resolution: Double hose clamps installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 24 March 2003 Resolved
Label all Life Jackets and Ring Buoys with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2003
Communications › Radio Communications
Issued 24 March 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 24 April 2003
Resolved 22 April 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 February 2003 Resolved
Properly labelall life jackets and life rings with the vessel's name. LEGACY COMPONENT DESC: Marking
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2003
Resolved 21 April 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.