MAURY USCG vessel records Sign in
← All vessels

IDC PEARL

IDC PEARL is a 2002 freight ship. The Coast Guard has recorded 22 inspections since 2002, most recently in March 2023, along with 8 deficiencies — 2 with no resolution recorded — and 5 operational controls.

Records from 2002 to 2023. Most recent: inspection, 31 March 2023.

Built
2002
Last inspected
31 March 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9245249 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
595647
Flag
TURKEY
—
Maury page id
psix-595647

Inspections, by type

…with no type recorded8
…past their stated due date2
Years with a record 12 calendar years (2002–2023)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it52344 - Dead Weight, Metric Ton
30085 - Convention (Subpart B), Gross Ton
18207 - Convention (Subpart B), Net Ton
60772 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

31 March 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7659908
9 May 2022 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7441149
5 May 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7444840
2 October 2019 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6826138
19 September 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6815525
16 October 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6557066
20 January 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6074108
17 June 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5903932
16 June 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5909821
14 June 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5907675
11 June 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5904203
29 March 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4825336
2 September 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3840360
23 February 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3681710
17 October 2008 Ballast Water Examination · Deficiency Check · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3346641
9 July 2008 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3263404
12 May 2008 Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3205289
23 January 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3134156
20 July 2005 Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2432167
28 July 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2148354
23 September 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1679032
21 September 2002 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1678450

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 31 March 2023 Resolved
Means shall be provided to control leaks of fammable liquids. PSCO observed a fuel oil leak from the number two generator fuel injector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 March 2023
Resolved 4 April 2023
Resolution: PSCO received Class Report attesting to repair of the leak from the NO.2 generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 March 2023 No resolution recorded
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a desing and construction adequate for the service for which they are intended. PSCO observed a water leak on the main engine seawater pump, both general service and fire pumps, ballast water pump, and major steam leak forward of main engine.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 March 2023 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 March 2023 No resolution recorded
Guard rails or bulwarks shall be fitted around all exposed decks. PSCO observed three broken stanchions on port side guard rail.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 March 2023 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 9 May 2022 Resolved
EACH LIFERAFT OR GROUP OF LIFERAFTS SHALL BE STOWED WITH A FLOAT FREE ARRANGEMENT COMPLYING WIHT THE REQUIREMENTS OF PARAGRAPH 4.1.6 OF THE CODE SO THAT EACH FLOATS FREE AND, IF INFLATABLE, INFLATES AUTOMATICALLY WHEN THE SHIP SINKS. THE SEA PAINTER WAS ATTACHED TO THE SHIP BY BYPASSING THE WEAK LINK, RENDERING THE LIFERAFTS TO NOT BE IN A FLOAT FREE ATTANGEMENT ON BOTH THE PORT AND STARBOARD LIFERAFTS.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 9 May 2022
Resolution: THE CREW WORKED WITH THE COAST GUARD TO PROPERLY STOW THE LIFERAFTS TO BE IN A FLOAT FREE ARRANGEMENT
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 17 June 2016 Resolved
0750 Fire Prevention- Doors fitted in boundry bulkheads of machinery spaces of and category A shall be reasonably gastight & self closing. PSCO observed 04 class A self closing fire resistant doors that were not self closing or missing their self closing devices. 74 SOLAS (2001) II-2/47.1 - 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 18 June 2016
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 17 June 2016 Resolved
0750 Fire prevention- Doors required to be self clothing shall not be fitted with hold back hooks. However, hold back arrangements fitted with remote release devices of the fail-safe type may be utilized. PSCO observed 03 self clothing doors either wedged open with cardboard or hold back hook. 74 SOLAS(2001) II-2/47.2 - 16a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 18 June 2016
Resolution: PSC NOLA received a class report from NKK satisfying the requirement.
Fire Fighting › Fire Main › Condition
Issued 17 October 2008 Resolved
0725 - Fixed Fire Fighting Installation - Fire fighting system shall be maintained ready for use. While conducting a deck walk the PSCO observed two pinholes that were one inch apart spraying water from the fire main between Cargo Hold #4 and #5. PSCO tapped on the area with an inspection hammer and the hole got bigger. Vessel needs to repair with class approval 74 SOLAS Con Ed. CH II Reg 14.1.1.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 October 2008
Resolved 20 October 2008
Resolution: Received fax stating branch pipe to hydrant at aft end (starboard) of cargo hold no.4 cropped out. New section fitted in length of aprox.2000 mm x 50 mm diameter. and welded. Fire main tested at pressure of 7 bar, satisfactory. From BUREAU VERITAS MARINE
Construction/Loadline › Markings › Load Line Mark
Issued 22 January 2008 Resolved
Load line not contrasting color from ships hull and deckline.
Action required: 705 - Other - as specified
Due 23 February 2008
Resolved 12 May 2008
Resolution: Vessel painted load line markings. Markings are contrasting colors with the hull. Cleared deficiency.

Ownership record