ZIM VIRGINIA is a 2002 freight ship. The Coast Guard has recorded 36 inspections since 2016, most recently in March 2026, along with 9 deficiencies and 3 operational controls.
Records from 2016 to 2026. Most recent: inspection, 4 March 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it54570 - Dead Weight, Metric Ton 74482 - Displacement, Metric Ton 53453 - Convention (Subpart B), Gross Ton 33604 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 36
4 March 2026Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319316
4 March 2026PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319374
18 February 2026Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8311942
23 December 2025Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8286742
15 August 2025Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8210424
15 August 2025PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8210428
28 January 2025Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8070317
23 January 2025PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8068772
29 November 2024Explosive Handling Operation-Commercial
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8041862
5 June 2024PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7927611
10 April 2024Deficiency Check · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7892256
4 April 2024PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7889886
10 October 2023Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7805948
6 October 2023Security Breach
Type not classified · Sector New York · USCG Northeast District (CGD-NE) · Activity 7804709
21 August 2023PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7773109
21 October 2022PSC A
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7581293
3 December 2020Damage Survey · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7105059
2 December 2020Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7104924
2 December 2020Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7105047
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 April 2024Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed steering failure on starboard side lifeboat, which is also designated as the vessels rescue boat. During the propulsion test the PSCO observed leaking hydraulic fluid.
74SOLAS(2020)III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2024
Resolved 11 April 2024
Resolution: Received dispensation from Flag State to clear the identified deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 April 2024Resolved
The following tests and inspections shall be carried out weekly and a report of the inspection shall be entered in the logbook. Weekly inspections were not conducted in accordance with vessels SMS procedures, last inspection was conducted on 31MAR2024.
74SOLAS(2020)III/20.6
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2024
Resolved 11 April 2024
Resolution: Received dispensation from Flag State to clear the identified deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2024Resolved
...the ignitability of combustible materials shall be restricted. PSCO observed oil drums and oil buckets as well as chemicals stored in the main engine room.
74 SOLAS (09) II-2/4.1.3
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2024
Resolution: Deficiencies rectified to the satisfaction of Class and Coast Guard.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 7 October 2019Resolved
Where davit arms are recovered by power, safety device shall be fitted which will automatically cut off the power before the davit arms reach the stops in order to prevent overstressing the falls or davits unless the motor is designed to prevent such overstressing.
Safety device on davit for port life boat not able to automatically cut off power.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 10 October 2019
Resolution: Class report provided on 10OCT19 clearing deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 July 2019Resolved
In addition to complying with the specific provision for fire integrity of bulkhead and decks mentioned elsewhere in the part, the minimum fire integrity of bulkheads and decks shall be as prescribed in tables 44.1 and 44.2. The class 'A' fire boundaries of the purifying room were not maintained due to holes or fractures in both bulkheads at the door frames and the fire door not closing properly. 74SOLAS (2001 Cons.) II-2/Reg.44.
Action required: 30 - Ship detained
Resolved 26 July 2019
Resolution: TEMPORARY REPAIRS APPROVED BY ABS WITH AN OPEN CONDITION OF CLASS STILL PENDING.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 July 2019Resolved
In a ship in which oil fuel is used, the arrangement for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and person on board. #1 supply booster pump for MGO purifier has a leak on the mechanical seal. 74SOLAS (2001 Cons.) Ch. II-2/ Reg 15.2
Action required: 30 - Ship detained
Resolved 26 July 2019
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPLACEMENT OF MECHANICAL SEAL FOR FUEL SUPPLY BOOSTER PUMP.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 July 2019Resolved
The company should ensure that each ship is manned with qualified, certificated and medically fit seafarers in accordance with national and international requirements. The third deck officer, third engineering officer and fourth engineering officer, does not have proper flag state endorsement. ISM CODE 6.2.1; STCW I/10, I/14.
Action required: 30 - Ship detained
Resolved 26 July 2019
Resolution: RECEIVED NOTIFICATION FROM VESSEL FLAG ADMINISTRATION
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 July 2019Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing.
The two of the engine room doors leading to the main deck accommodation spaces were damaged and no longer functional. 74 SOLAS (2001 Cons.) II-2/REG. 47
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2019
Resolution: RECEIVED CLASS REPORT.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 July 2019Resolved
Except as provided in paragraph 4, two means of escape shall be provided from each machinery space of category A. Steering gear compartment door can be locked from the outside blocking the second means of egress. 74 SOLAS (2001 Cons.) II-2/Reg. 45
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2019
Resolution: CLASS SURVEY RECEIVED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.