INDUSTRIAL CRESCENT

INDUSTRIAL CRESCENT is a 2002 freight ship. The Coast Guard has recorded 101 inspections since 2002, most recently in April 2019, along with 96 deficiencies, 24 operational controls and 16 casualty investigations between 2010 and 2018.

Records from 2002 to 2019. Most recent: inspection, 19 April 2019.

Built
2002
Last inspected
19 April 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9258193 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2210
596395
Flag
MARSHALL ISLANDS
368596000 (licence lapsed)
Maury page id
psix-596395

Inspections, by type

…with no type recorded46
Years with a record 16 calendar years (2002–2019)
The 101 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it7252 - Convention (Subpart B), Gross Ton
2982 - Convention (Subpart B), Net Ton
12346 - Displacement, Ton
8097 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDF4929MMSI 368596000 · cancelled · compulsorily equipped · granted 15 June 2010, cancelled 29 January 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 101

19 April 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6666203
15 February 2019 Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6628357
9 February 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6621483
17 January 2019 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6621552
3 January 2019 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6584349
30 December 2018 Type not recorded
No type recorded · Activities Europe · Activity 6604647
26 November 2018 Deficiency Check
Physical examination · Activities Europe · Activity 6586391
15 November 2018 Damage Survey
Physical examination · Activities Europe · Activity 6581140
14 November 2018 Type not recorded
No type recorded · Activities Europe · Activity 6584059
22 October 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6566022
9 October 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6557330
29 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6526488
24 August 2018 Administrative Inspection
Administrative · Activities Europe · Activity 6521326
18 August 2018 Type not recorded
No type recorded · Activities Europe · Activity 6527075
13 August 2018 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6498589
10 August 2018 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6506780
8 August 2018 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6504367
8 July 2018 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6474245
2 July 2018 MSP Periodic Oversight · MTSA/ISPS Verification · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6459933
28 June 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6458767
12 May 2018 Damage Survey
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6413710
7 April 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6390834
14 February 2018 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6372182
6 February 2018 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6350049
5 February 2018 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6685303
4 February 2018 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6385525
11 October 2017 Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6285256
10 October 2017 MARPOL Annex I Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6284461
4 October 2017 MSP COI Oversight · ISM SMC Audit · MSP Select Additional Oversight – Risk Assessment · Administrative Inspection · Hull Examination · COI Inspection · Drydock Exam
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6280796
12 September 2017 COI Inspection · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6262668
23 August 2017 Administrative Inspection · Deficiency Check · Damage Survey · ISM Oversight · ISM SMC Audit · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6251391
10 August 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6249884
1 August 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6227253
26 July 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6221667
25 July 2017 Examination of Repairs · MSP COI Oversight · COI Inspection · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6219053
11 July 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6318225
28 June 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6226769
28 June 2017 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6265355
23 April 2017 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6133440
7 January 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6086051
1 July 2016 MARPOL Annex V Examination · Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · MTSA Verification
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5925539
28 March 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5840549
23 March 2016 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5838950
21 December 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5785266
24 November 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5769264
13 October 2015 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5741494
11 October 2015 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5741553
19 August 2015 MTSA/ISPS Verification · Annual Inspection · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5220632
20 July 2015 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5189275
13 July 2015 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5177232
27 October 2014 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5012714
23 October 2014 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5015813
26 March 2014 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4823537
7 March 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4814647
1 March 2014 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4808417
17 July 2012 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4384229
6 June 2012 COI Inspection · Internal Structural Exam · Drydock Exam · Deficiency Check · MTSA/ISPS Verification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4335863
10 May 2012 MTSA/ISPS Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4306712
30 January 2012 Type not recorded
No type recorded · Activities Europe · Activity 4235059
27 January 2012 Type not recorded
No type recorded · Activities Europe · Activity 4235019
9 January 2012 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 4218045
18 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4210282
12 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4206322
11 December 2011 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4206853
23 September 2011 Security Breach
Type not classified · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 4156063
15 August 2011 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4116496
9 August 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4110545
18 July 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4549963
4 February 2011 Damage Survey · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3939336
31 January 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3936422
23 January 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3933294
28 November 2010 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3907848
27 January 2010 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3670711
24 December 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3651647
27 April 2007 ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2916922
27 October 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2809524
12 February 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2583829
16 September 2005 ISPS II Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2496750
28 February 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2300652
24 January 2005 Ballast Water Examination · PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2279721
21 January 2005 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2278688
27 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2229927
21 August 2004 PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2171988
28 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2148244
4 March 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2018686
3 March 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2017074
2 March 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2016576
2 March 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2016902
9 January 2004 MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1981921
5 October 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1921681
5 October 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1922155
8 September 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1899746
5 September 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1897663
16 August 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1878125
12 August 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1879790
26 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1859459
24 July 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1855905
23 July 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1856803
19 June 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1821537
3 October 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1683889
27 September 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1682240

Deficiency record · 96

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 26 November 2018 Resolved
A food ration consisting of not less than 10,000kj for each person the life raft is permitted to accommodate. These rations shall be palatable, edible throughout the marked life. The Rations shall be packed in permanently sealed metal containers or vacuum packed in a flexible packaging material. Vacuum seal for numerous food rations is broken and air has leaked into the food.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 December 2018
Resolved 14 December 2018
Resolution: Recieved photos of new food ratiions.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 November 2018 Resolved
An inflatable liferaft must be serviced at a facility specifically approved by commandant for the particular brand, no later than the month and year on its services sticker affixed under 46CFR160.151-57(n). Last Servicing of the 6 man liferaft, starboard liferaft and spare liferaft for embarked security personnel was October 2017. 46CFR199.99(g)3, 74SOLAS(14)III/20.8.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 December 2018
Resolved 14 December 2018
Resolution: Recieved copies of the liferaft certificates.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 November 2018 Resolved
Operational readiness, systems, and appliances shall be maintained ready for use. One of the cargo hold fixed CO2 bottles was found disconnected from the main discharge manifold. Ship's crew tightened while the MI's were on board. SOLAS II-2/14.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 1 December 2018
Resolved 1 December 2018
Resolution: Ships force corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 November 2018 Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances, shall be in working order and ready for immediate use. Attending USCG inspectors noted that the bracket holding the keel cooler onto the lifeboat was broken. SOLAS III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 December 2018
Resolved 3 December 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 26 November 2018 Resolved
Each transfer pipe system used for the transfer of oil or liquid hazardous material to or from a vessel with the capacity of 250 barrels or more must not leak under a static liquid pressure of 1.5 times the max allowable working pressure on an annual basis. Vessel has not tested the bunker lines in over 16 months. Prior to bunkering operations in the U.S. complete a hydrostatic test and provide evidence of the same. 33CFR156.170
Action required: 703 - Prior to bunkering operations
Due 24 December 2018
Resolved 24 December 2018
Resolution: Recieved confirmation of testing onboard the vessel/
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 26 November 2018 Resolved
Vessel has a cracked block on the inboard Generator causing a small jacket water leak, it was previously documented by Sector San Fransisco on an 835, however that activity was closed as this was turned over to DNV-GL as a condition of class , however the due date was 2JAN19. For tracking purposes I've dated this due for 1FEB18 as no USCG unit is currently tracking the repairs.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 February 2019
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 November 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regualtions to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons on board. The main diesel engine #5 cylinder has a crack in the cylinder head and is overheating, rendering the main engine inoperable. Dead ship tow is authorized from Casablanca, Morocco to Rota, Spain, where repairs to the #5 cylinder head main engine shall be completed prior to departure. Submit RO repair report for satisfactory vessel operation to the USCG for review.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2018
Resolved 24 December 2018
Resolution: Recieved DNV GL survey following sea trials, the engine has been repaird with OEM rep and conducted operational tests.
10 - Safety of Navigation › N/A - No Subsystem › Long-range identification and tracking system (LRIT)
Issued 29 August 2018 Resolved
Vessel has failed to report via LRIT per 33 CFR 169.230.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2018
Resolved 18 December 2018
Resolution: Verified LRIT was broadcasting to NAVCEN Via phone call, discussed with [name withheld] and was approved to clear this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 August 2018 Resolved
The ship shall remain fit to proceed to sea in all respects without danger to the ship or persons on board. During operational testing as part of witnessing PSTPs, the slowdown manual override test failed to operate as designed and pitch did not return to previous set point.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 15 August 2018 Resolved
The ship shall remain fit to proceed to sea in all respects without danger to the ship or persons on board. During operational testing as part of witnessing PSTPs, standing alarms were found on engineers panels in berthing and mess deck althgouh no active alarms were indicated in ECR. Ensure all engineer alarm panels throughout vsl are functioning as designed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 15 August 2018 Resolved
The company and ship shall comply with requirements of the ISM Code. During operational testing as part of witnessing PSTPs, Section 1.0 Fire Alarm System, repeatedly mentions manual pull stations for fire alarm. Pull stations are not listed in SMS and are not being routinely tested.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 August 2018 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. During operational testing as part of witnessing PSTPs, the air conditioning unit in ECR failed to stop when "D07SL04" was pushed (2.4f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 August 2018 Resolved
Fire protection system and fire fighting system and appliances shall be maintained ready for use. During operational testing as part of witnessing PSTPs, Emergency fuel valves #4355, #4357, and #4803 failed to close during emergency fuel valve shutdown test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 August 2018 Resolved
Fire protection system and fire fighting system and appliances shall be maintained ready for use. Manual pull for thermal oil expansion tank fuel shut off valve failed to operate and shall be included in ship's SMS for testing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 15 August 2018 Resolved
The ship shall remain fit to proceed to sea in all respects without danger to the ship or persons on board. During operational testing as part of witnessing PSTPs, low level alarm on the diesel oil day tanks (fwd/aft) #1 and #2 failed to alarm due to faulty floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 15 August 2018 Resolved
An emergency means of communication must provide common talking means of two way voice communications and calling among navigation bridge and emergency control stations. During operational testing as part of witnessing PSTPs, it was determined that the vessel does not have headsets for vsl's sound powered telephone system. Provide headsets for steering gear station and CPP station (section 9.0)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 August 2018 Resolved
the Ship shall remain fit to proceed to sea in all respoects without danger to the crew or the ship. During operational testing as part of witnessing PSTPs, the manual (back up) pitch setting "ahead" and "astern" buttons failed to operate.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 August 2018 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. During operational testing of Flame Detectors as part of witnessing PSTPs, 03 of 03 flame detectors were non-operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2018
Resolution: Vsl installed new flame detectors and operationally tested iaw PSTPs 1.3 in presence of MI
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 August 2018 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. During operational testing as part of witnessing PSTPs, Loop 7 of the fire detection system has been removed from operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2018
Resolution: Vsl reconnected Loop 7 and disconnected dryer in laundry room, operationally tested, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 August 2018 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Portable fire extinguishers not properly service with 33 (approx half requiried) have not had required hydrostatic testing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2018
Resolution: Vsl found proper servicing report indicating all but 03 need hydrostatic testing. Replaced with like foreign extinguishers while being serviced.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 10 August 2018 Resolved
Fire Control Plans shall be kept up to date. Update Fire Control Plan to reflect size, type, and location of portable fire extinguishers on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 10 August 2018 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. During operational testing as part of witnessing PSTPs, the fuel injector leakage alarm on the M/E is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 August 2018
Resolved 15 August 2018
Resolution: Crew calibrated and replaced sensor. Demonstrated proper operation iaw PSTP 4.17.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 August 2018 Resolved
The ship shall remain fit to proceed to sea in all respects without danger to the ship or persons on board. During operational testing as part of witnessing PSTPs, Hydraulic Lock alarm on #1 steering pump has bad module rendering it inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 10 August 2018 Resolved
The ship shall remain fit to proceed to sea in all respects without danger to the ship or persons on board. During operational testing as part of witnessing PSTPs,the 3/E alarm panel dies not alarm aftr 3 minute interval iaw PSTP 6.4.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to MI
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 July 2018 Resolved
Repair zip-tied emergency steering solenoid on #2 steering pump within 30 days (74 SOLAS 14 Consolidated I/11).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 3 July 2018
Resolution: Witnessed satisfactory replacement and installation of solenoid.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 2 July 2018 Resolved
Provide guard for rotating machinery on A/C compressor fan belt accessible to crew in steering compartment within 30 days (74 SOLAS 14 Consolidated I/11).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 3 July 2018
Resolution: Crew installed guard.
10 - Safety of Navigation › N/A - No Subsystem › Establishment of working language onboard
Issued 2 July 2018 Resolved
Engine Order Telegraph (EOT) listed orders are not in the language of the crew. Label EOT orders in English. SOLAS Cons(2004)Ch.II-1/26.10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 August 2018
Resolved 3 July 2018
Resolution: Crew replaced labels on EOT in English.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 July 2018 Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Fire main serving port bridge wing fire hydrant found corroded in vicinity of turn at deck and failed when hammer tested, producing a hole of approximately 1 inch. Repair wastage as original, and visually inspect and pressure test entire system to the satisfaction of class and the USCG. SOLAS Cons(2014) Ch.II-2/14.1.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 4 July 2018
Resolved 4 July 2018
Resolution: Verified replacement of wasted portion of fire main. Conducted visual inspection of entire fire main under pressure.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2018 Resolved
Maintenance testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Fixed CO2 cylinder protecting the EDG space found corroded at base. Replace with approved cylinder IAW manufactures instructions to the satisfaction of the attending marine inspector or class surveyor. SOLAS Cons(2014) Ch.II-2/14.2.2.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 4 July 2018
Resolved 4 July 2018
Resolution: Verified installation of new CO2 cylinder.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 July 2018 Resolved
Crew members shall be trained to be familiar with the arrangements of the ship as well as the location and operation of any fire-fighting systems and appliances that they may be called upon to use. Operating instructions for the EGD fixed CO2 system found to be inaccurate. Provide accurate instructions for operation and ensure all crew are trained in their use. SOLAS Cons(2014) Ch.II-2/15.2.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2018
Resolved 4 July 2018
Resolution: Verified proper instructions for EDG CO2 discharge in place.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 July 2018 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Rescue boat fixed means of bailing required by FSA code 5.1.1.10 found deteriorated and inoperable. The vessels bow light was also found inoperable. Repair both items and prove proper operation to the attending marine inspector or class surveyor. SOLAS Cons(2014)Ch.III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2018
Resolved 4 July 2018
Resolution: Verified installation of new bow light and bailing system with operational test of both.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 July 2018 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Fire main cross-over valves throughout the fire main system found with heavily corroded handles with wasted locking springs. Provide replacement handles to the satisfaction of the attending marine inspector or class surveyor. SOLAS Cons(2014) Ch.II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2018
Resolved 4 July 2018
Resolution: Verified replacement of all wasted handles and associated parts.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 2 July 2018 Resolved
A minimum of two two-way portable radiotelephones apparatus for each fire party for fire-fighter’s communication shall be carried on board. Those two-way radiotelephone apparatus shall be of an explosion-proof type or intrinsically safe. Required radiotelephones were not aboard. Provide required radiotelephones at the two emergency gears lockers and prove proper operation to the attending marine inspector or class surveyor. SOLAS Cons.(2014)Ch.II-2/10.10.4
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2018
Resolved 4 July 2018
Resolution: Verified proper amount of portable communications available with satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 2 July 2018 Resolved
The fire-fighter’s outfits or sets of personal equipment shall be kept ready for use in an easily accessible location that is permanently and clearly marked and, where more than one fire-fighter’s outfit or more than one set of personal equipment is carried, they shall be stored in widely separated locations. Vessel found with all fire-fighting outfits stored in the same location. Vessel shall separate the required fire-fighting outfits into both of the onboard emergency gear lockers to the satisfaction of the attending marine inspector or class surveyor. SOLAS Cons.(2014)Ch.II-2/10.3.1
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2018
Resolved 4 July 2018
Resolution: Verified sufficient number of fire fighting outfits stored in separate lockers.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 2 July 2018 Resolved
8. Bits, rollers, and leads found corroded and heavily scaled which is causing damage to the mooring lines. Remove scale, smooth bitts, rollers, and leads. Vessel to install chafing gear on mooring lines until corrected to the satisfaction of class. SOLAS(2014)Ch.1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 4 July 2018
Resolved 4 July 2018
Resolution: Crew installed chaffing gear on mooring lines.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 July 2018 Resolved
Vessel found with multiple discrepancies related to fire fighting systems and appliances. Vessel shall undergo an external audit of the SMS. SOLAS Cons(2014) Ch. IX/5
Action required: 15 - Rectify deficiencies by next port
Due 7 July 2018
Resolved 8 July 2018
Resolution: External audit completed by ABS [name withheld], [name withheld]. Seven (07) corrective action requests (CARs) /observations issued; no major non-conformities. ABS issued short-term Safety Management Certificate (SMC) valid 08Jul2018-08Oct2018.
Navigation › Collision/Grounding Avoidance › Radar
Issued 6 February 2018 Resolved
Vessel's port radar stopped rotating. The brushes were fried on the antenna motor and the unit will not rotate.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2018
Resolution: uploaded Technician report into MISLE. All Sat.
Electrical › Electric Generation Source (service) › Generator
Issued 6 February 2018 Resolved
#1 SSDG overheated and shutdown. Crew found plastic bags in the strainer and believe prevented cooling water into the #1 SSDG. This caused the SSDG temperatures to shoot up high overheating it and causing a shutdown. Vessel lost power for 15 min.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2018
Resolution: C/E cleaned out the strainers and the #1 SSDG is operating normally.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 6 February 2018 Resolved
NAVTEX fuse was blown. Fuse changed out and unit energized. Unit started and tested all day but vessel is not receiving messages.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2018
Resolution: Uploaded technician report into MISLE. All Sat.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 18 December 2017 Resolved
1. Complete vibration analysis alignment per DNV-GL outstanding condition of class, provide completed 3rd party report and take the appropriate action for repairs if recommended. Reference DNV-GL NCR for details and complete to satisfaction of MIDET Singapore, Sector HONO and local OCMI.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 9 April 2018
Resolution: Crowley and DNV GL eng provided reports detailing other methods for ensuring reduction gear is operating satisfactorily.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 18 December 2017 Resolved
2. Update PSTS regarding incorrect set points, procedures and missing steering test requirement and submit to Coast Guard, Marine Safety Center for approval. Complete to satisfaction of MIDET Singapore, Sector Hono, and the local OCMI.
Action required: 705 - Other - as specified
Due 2 October 2018
Resolved 17 January 2019
Resolution: Cleared due to vsl reflag to [name withheld] date extended from 18Feb2018 to 02Oct2018 per MISLE Activity #6459933. SNC attempted to clear, unable to complete on 15Aug18 due to multiple issues (Act # 6506780).
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 4 December 2017 Resolved
The safety management system shall be maintained in accordance with the provisions of the International Safety Management Code. Over 180 items were marked as substandard during the recent dry dock inspection. The Flag Administration has identified numerous areas of non-conformity including but not limited to: A) Failure to report to nearest USCG OCMI when temporary repairs were made to a hole in the hull. B) Inadequate training for crew members authorized to use the oily water separator C) Inadequate training for correct logging of Oil Record Book Entries. D) Unauthorized alterations in engine room piping including bypass pipes between sludge tank and Dirty Oil Tank and incorrect safety relief valves. E) Substandard sanitation and accommodation for galley sinks and drains, leaking ceiling in food stores, and sewage smell throughout accommodations for months F) Substandard vessel maintenance of deck equipment, ventilation ducts, fire fighting dampers, many of the discrepancies were not properly identified or addressed G) Vessel Security Plan Control-copies of VSP were used as scrap pages in engine room An external SMS audit is required prior to departure from Singapore. Based on the number and scope of the non-conformities detected, we do not believe the SMS has been properly implemented. The scope of the audit is to determine the prevalence of non-implementation of the SMS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2017
Resolution: USCG attended SMS audit with ABS
Fire Fighting › Ventilation Systems › Ducts
Issued 2 November 2017 Resolved
Wasted ventilation duct improperly repaired, non-approved sheet metal used instead of A-0 or equivalent. Complete insert as per original design and agreement. Complete repair to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Duct repaired properly.
Engineering › Pressure Vessel › Relief Valve
Issued 2 November 2017 Resolved
Safety relief valves on the air receivers exceed the working pressure as rated on the bottles (data plate). Install relief valves that relieve at or below MAWP to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Data plates added and relief valves set at MAWP added.
Fire Fighting › Combustible Materials › Insulation
Issued 2 November 2017 Resolved
Oil soaked lagging identified in the engine room exhaust trunks poses fire and safety hazards. Replace oil soaked lagging IWO of the exhaust trunks and complete to satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Lagging replaced
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 2 November 2017 Resolved
Engine room fire damper wasted at the butterfly stem. Complete repair to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Repair completed
Electrical › Lighting (service) › Lighting Fixture
Issued 2 November 2017 Resolved
Replace all damaged and broken light fixtures. Complete repair to satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2017
Resolution: Over 50 light fixtures were repaired/replaced.
Engineering › Fuel Oil Service System › Flange
Issued 2 November 2017 Resolved
Complete repair to the lube oil flange at the boiler. Complete repair to satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2017
Resolution: Flange repaired. Inspector witnessed.
Fire Fighting › Combustible Materials › Insulation
Issued 2 November 2017 Resolved
Replace damaged lagging in the engine room exhaust; make repair to satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Lagging replaced
Fire Fighting › Ventilation Systems › Ducts
Issued 2 November 2017 Resolved
Crop and renew wasted E-generator ventilation supply trunk. Make damper available for inspection and complete repair to satisfaction of the attending Marine Inspector. Doublers are not allowed in repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Repairs completed
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 2 November 2017 Resolved
Sewage smell permeates accommodation space. Identify cause and eliminate smell.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2017
Resolution: Valve and pressure gauge were added to system.
Construction/Loadline › Hull › Side Shell
Issued 2 November 2017 Resolved
Make repairs to STBD and PORT side shell to the satisfaction of the attending Marine Inspector. Provide repair plans, and make available at fit up, back gouging, and final NDT.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2017
Resolution: Repairs completed
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 2 November 2017 Resolved
Conduct UTM of remaining areas in Cargo Hold #1 to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2017
Resolution: UTM Report Received. Steel thickness within allowance.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 2 November 2017 Resolved
Clean galley floor drain.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2017
Resolution: Galley floor drain chemically cleaned
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump
Issued 2 November 2017 Resolved
Conduct test of newly installed water cooling system to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2017
Resolution: Witnessed initial testing. Class witnessed final testing after one nozzel was adjusted.
Engineering › Steering Gear System › Rudder
Issued 2 November 2017 Resolved
Conduct Sea Trials to include testing of the rudder and steering gear system to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 December 2017
Resolution: Vessel conducted 03 sea trials. Steering gear passed class inspection and testing on 11DEC17
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 November 2017 Resolved
Folding stanchions and respective brackets at rescue boat are wasted. Repair or renew to original to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2017
Resolution: Stanchions fabricated and work.
Fire Fighting › Combustible Materials › Insulation
Issued 2 November 2017 Resolved
Insulation in dry stores of galley is saturated. Remove affected areas and make area available to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2017
Resolution: Panels removed, insulation on pipes properly installed
Fire Fighting › Combustible Materials › Insulation
Issued 2 November 2017 Resolved
Insulation in dry stores of galley is saturated. Replace insulation with approved materials IAW structural fire protection requirements to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2017
Resolution: Insulation and Panels replaced with approved material.
Fire Fighting › Structural - A Class Divisions › Workshops
Issued 2 November 2017 Resolved
Wire run through engine room workshop missing fire retardant packing. Add approved packing to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 November 2017
Resolution: Fire caulk added to wire run.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 2 November 2017 Resolved
Rescue boat engine stalled multiple times during testing. Retest to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2017
Resolution: Spaark pulg was replaced. Tested rescue boat with USCG present, all sat.
Engineering › Reduction Gearing/Clutches › Bearing
Issued 16 October 2017 Resolved
Conduct root cause analysis of the failure of the reduction gear. Provide report to USCG MIDET Singapore.
Action required: 705 - Other - as specified
Resolved 23 November 2017
Resolution: Report Received with mitigating/preventative actions for future
Engineering › Reduction Gearing/Clutches › Bearing
Issued 12 September 2017 Resolved
Complete maintenance/repairs & tests listed in Sector Honolulu Dry Dock Worklist issued on 13SEP2017. Items must be completed prior to issuance of new COI after completion of 2017 Dry Dock in Singapore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 15 December 2017
Resolution: Work list items cleared or rescinded. See narrative
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 September 2017 Resolved
Submit plans to DNV-GL to install pressure relief valve in fuel oil bunker line. Relief valve is needed to protect the bunker line from overpressure as required by 74 SOLAS 2001, Chap II-2, Reg 15.2.7
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 8 November 2017
Resolution: 835 void. Vessel Requested Reconsideration, NVIC 10-99 does not require the relief valve. See activity 6280796 for more information.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 12 September 2017 Resolved
Install pressure relief valve in fuel oil bunker line. Relief valve is needed to protect the bunker line from overpressure as required by 74 SOLAS 2001, Chap II-2, Reg 15.2.7
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 8 November 2017
Resolution: 835 void. Vessel Requested Reconsideration, NVIC 10-99 does not require the relief valve. See activity 6280796 for more information.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 12 September 2017 Resolved
Review & add necessary items to the vessel's fuel oil transfer procedures. Procedure contents must be in accordance with 33 CFR 155.750. Item must be completed prior to issuance of new COI at completion of 2017 dry dock in Singapore
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 6 November 2017
Resolution: Vessel corrected and updated Fuel Oil Transfer Procedures
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 12 September 2017 Resolved
Update Periodic Safety Test Procedures. Steps for test 5.9 & 5.10 must include steps & equip needed to test the high temp sensors. Also, add procedures to test the high temp alarms for the thrust bearing & reduction gear oil temperature. Submit updates to MSC for approval. Item must be completed prior to issuance of new COI. May be extended pending review/approval.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 18 December 2017
Resolution: Requirement for updates to PSTP included with new 835 issued by MIDET Singapore 18DEC17. See MISLE 6280796
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 12 September 2017 Resolved
Submit plans to DNV-GL to add high temperature alarms & automatic load reduction on high temperature, for the reduction gear input shaft and PTO shaft bearings. Items are required to be monitored/alarmed to meet 74 SOLAS 2001, Chap II-2, Reg 52, Reg 53.4.1 & 53.4.3 as failure of these bearings led to the loss of the reduction gear on 09-10 Aug 2017.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 November 2017
Resolution: 835 void after request for reconsideration from company was approved and other mitigating/preventative actions taken by company see MISLE activity 6280796.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 12 September 2017 Resolved
Install high temperature alarm & load reduction for high temperature of the reduction gear input shaft & PTO bearings. Timeline dependent upon plan approval from DNV-GL. Once installed, add procedures to the vessel's Periodic Safety Test procedures to test the alarms and auto load reduction feature; submit additions to the PSTP to MSC for approval.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 5 December 2017
Resolution: 835 void after request for reconsideration from company was approved and other mitigating/preventative actions taken by company see MISLE activity 6280796.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 23 August 2017 Resolved
Vessel probibited from departing any port within Sector Honolulu COTP Zone until proper operation of the vessels propulsion approved by CG MI.
Action required: 705 - Other - as specified
Due 23 August 2017
Resolved 12 September 2017
Resolution: A sea trial with 70% CPP pitch and ship normal electric load on the shaft generator at sea was carried out for approx. 1 hr and confirmed the reduction gear operates in the normal condition.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 29 July 2017 Resolved
Vessel restricted from lifting cargo hatches until permanent repairs are completed during August 2017 drydock. IAW NVIC 01-13 CH 1
Due 30 August 2017
Resolved 28 November 2017
Resolution: Cargo hatch covers repaired, hose test successfully witnessed by class.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 25 July 2017 Resolved
Provide documentation that vessels automation installation meets the minimum requirements of 46CFR61.50-30 in addition to all requirements required by DNVGL for EO notation.
Due 30 August 2017
Resolved 5 December 2017
Resolution: 835 is void as vessel meets reqirements of MSP NVIC 01-13 CH1 to operate PUMS.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 July 2017 Resolved
Vessel conducted commercial operations with an expired Certificate of Inspection. Vessel departed Singapore on June 29, 2017 headed for Japan to load cargo. The vessel departed Japan on July 10, 2017, bound for Concord, CA. The vessel arrived in Concord, CA on July 24, 2017 and the COI expired on June 30, 2017.
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 5 December 2017
Resolution: Deficiency added to enable the vessel inspection activity to be successfully referred for enforcement. Deficiency cleared.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 8 July 2016 Resolved
A CLASS DOOR ADJACENT TO BOSN STATEROOM DOES NOT FULLY SELF CLOSE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 4 August 2016
Resolution: Class has assumed responsibility under MSP Select program.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 July 2016 Resolved
A-0 mini door between panty/galley as well as galley CO2 system not on fire plan
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 4 August 2016
Resolution: Class has assumed responsibility under MSP Select program.
Lifesaving › Rescue Boat › Propulsion Casing/Protection
Issued 8 July 2016 Resolved
Cort nozzle prop protection damgaged during use, needs repair/replace
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 4 August 2016
Resolution: Class has assumed responsibility under MSP Select program.
Lifesaving › Launching Appliances › Davit
Issued 8 July 2016 Resolved
Not mechanical stop or cut out for slewing davit into life rafts and free-fall davit.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 4 August 2016
Resolution: Class has assumed responsibility under MSP Select program.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 8 July 2016 Resolved
Temp/leaky Soft patches found on sludge piping running from steering space into sludge tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 4 August 2016
Resolution: Class has assumed responsibility under MSP Select program.
Lifesaving › Launching Appliances › Falls
Issued 8 July 2016 Resolved
two fish hooks found in hockled davit wire.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 4 August 2016
Resolution: Class has assumed responsibility under MSP Select program.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 1 July 2016 Resolved
Hatch to Bosn Locker doesn't seal properly, "super foam" used to make weather tight. Nees to be adjusted and/or repaired
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 4 August 2016
Resolution: Class has assumed responsibility under MSP Select program.
Navigation › Piloting/Steering › Gyro Compass
Issued 24 November 2015 Resolved
Vessel reported failure of Gyro-Compass. Gyro-Compass must be repaired prior to leaving port of St. Petersburg, Russia. SOLAS V/19.2.2.5.1
Action required: 705 - Other - as specified
Due 27 December 2015
Resolved 29 November 2015
Resolution: Received class report stating gyro system has been properly serviced and is funtioning fully.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 July 2015 Resolved
Provide a fully manned engine room watch with three sections, each having one licensed and one unlicensed engineer
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 19 August 2015
Resolution: Automation notation added to Class certificate.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 July 2015 Resolved
In accordance with vessels COI and condition of operation demonstrate proper engine room automation and attain class designation as ACC or ACCU
Action required: 705 - Other - as specified
Due 12 August 2015
Resolved 19 August 2015
Resolution: AUT notation noted on class certificate.
Lifesaving › Immersion Suits › General
Issued 2 August 2012 Resolved
Two different types of immersion suits onbd - 1 requires PFD to be worn & the other not. Ensure immersion suits & donning instructions are same for all suits onbd. New suits must be USCG approved. SOLAS, LSA 2.3, Resolution A.520 (13) 2.1. Must be resolved w/i 30 days and prior to operating N of 32deg N latitude or S of 32deg S latitude.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 29 September 2012
Resolution: Verified 34 immersion suits onboard.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 August 2012 Resolved
Provide proper stowage for PFD and immersion suits in accommodation spaces & properly label their locations with required IMO symbols ensuring compliance w/ the Fire Control & Life Safety Plan. SOLAS, Reg. 2.2 IMO Res. A.520(13)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 29 September 2012
Resolution: Verified PFDs and immersion suits were stowed in accommodation spaces and their locations were properly labled with IMO symbols.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 August 2012 Resolved
Replace life ring lines on the port & stbd aft cargo deck ring buoys. SOLAS III, Reg 7.1.2.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2012
Resolved 2 August 2012
Resolution: Lines renewed and found satisfactory by GL surveyor.
Lifesaving › Inflatable Liferafts › Markings
Issued 2 August 2012 Resolved
Replace the life raft instructions at the stbd aft deck life raft launching station. SOLAS III, Reg. 4
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 29 September 2012
Resolution: Verified new life raft instructions were ordered and placed at the stbd aft deck life raft launching station.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 August 2012 Resolved
Supply a current Coast Pilot onboard. SOLAS V, Reg 27
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 29 September 2012
Resolution: Verified current Coast Pilot (1-5) were current and on the bridge; Coast Pilot 5 was a new order.
Operations/Management › Pollution › Other MARPOL Annex VI Deficiencies
Issued 2 August 2012 Resolved
Submit an application for the vessel EIAPP to the EPA and provide evidence of such submission to CG Sector Mobile. MARPOL 73/78 Annex VI
Action required: 705 - Other - as specified
Due 15 October 2012
Resolved 15 October 2012
Resolution: Vessel rep submitted the EIAPP applications to the EPA for equipment onboard.
Operations/Management › Pollution › Other MARPOL Annex VI Deficiencies
Issued 2 August 2012 Resolved
Submit a copy of the EPA issued EIAPP to Coast Guard Sector Mobile upon receipt. MARPOL 73/78, Annex VI
Due 2 February 2013
Resolved 22 February 2013
Resolution: Showed proof of EPA issued EIAPP certificate for vessels main engine.
Operations/Management › Pollution › Approved Method for Annex VI Compliance
Issued 2 August 2012 Resolved
After EIAPP is approved & issued, conduct a MARPOL 73/78 Annex VI verification survey in accordance with CG-543 Policy Letter 09-01, enclosure (1). The survey may be completed by the USCG or by class on behalf of the USCG.
Due 2 August 2013
Resolved 2 December 2013
Resolution: Rcvd approved EIAPP and endorsed the IAPP, no further action required.
Lifesaving › Lifefloat › Serviceable
Issued 6 June 2012 Resolved
Lifeboat release mechanism was tested without 1.1 times B weight required by SOLAS III Reg 20/11.2.3 on testimony from Survival Systems International that it was not required. Mfr supporting documentation was not supplied with the lifeboat certs as required by CG during inspection. Issued CG-835 to have lifeboat retested IAW SOLAS with 1.1 times the B weight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2012
Resolved 29 September 2012
Resolution: Witnessed test of lifeboat release mechanism IAW SOLAS III Reg 20/11/2/3.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 18 December 2011 Resolved
Provide tech report upon renewal of printer circuit board.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 December 2011
Resolution: Received tech report. All sat.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 24 January 2005 Resolved
MAKE PERMANENT REPAIR TO SALTWATER RECIRCULATING PIPE IWO MAIN FIRE PUMP.
Action required: 705 - Other - as specified
Due 24 February 2005
Resolved 28 February 2005
Resolution: Recived class report attesting to the satisfactory repair to the seawater recirculating pipe. Damaged pipe was replaced with a newly fabricated lenght of pipe.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 24 January 2005 Resolved
PROCURE A NEW FIREMAN'S OUTFIT. HOLES IN THE WEB OF THE GLOVES AND REFLECTIVE LAMINATE DETERIORATING THROUGHOUT.
Action required: 705 - Other - as specified
Due 24 February 2005
Resolved 7 February 2005
Resolution: RECEIVED PURCHASE INVOICE OF NEW FIREMAN''S OUTFIT.
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 21 August 2004 Resolved
Free Fall Life Boat missing (2) two Boat Hooks.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2004
Resolution: RECEIVED FAXED RECEIPT FOR PURCHASE OF 02 BOATHOOKS.

Casualty record · 16

3 August 2010Routine · role: Involved in a Marine Casualty · activity 3814857
28 November 2010Routine · role: Involved in a Marine Casualty · activity 3907848
23 January 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3933294
18 April 2011Routine · role: Involved in a Marine Casualty · activity 3990415
11 December 2011Routine · role: Involved in a Marine Casualty · activity 4206853
27 January 2012Routine · role: Involved in a Marine Casualty · activity 4235019
30 January 2012Routine · role: Involved in a Marine Casualty · activity 4235059
13 December 2013Routine · role: Involved in a Marine Casualty · activity 4770096
23 April 2017Routine · role: Involved in a Marine Casualty · activity 6133440
11 July 2017Routine · role: Involved in a Marine Casualty · activity 6318225
10 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 6249884
4 February 2018Routine · role: Involved in a Marine Casualty · activity 6385525
5 February 2018Routine · role: Involved in a Marine Casualty · activity 6685303
18 August 2018Routine · role: Involved in a Marine Casualty · activity 6527075
14 November 2018Routine · role: Involved in a Marine Casualty · activity 6584059
30 December 2018Routine · role: Involved in a Marine Casualty · activity 6604647
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

OCEAN CRESCENT (2010–2018). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.